Radiant EASYREMOTE Manuel utilisateur

EASYREMOTE - RAD - ING - MAN.INST - 1010B - 40-00017
Technical specification RADIANT BRUCIATORI S.p.A. Montelabbate (PU) ITALY ENGLISH
Instruction manual
remote control device
EASYREMOTE


GENERAL INFORMATION
Technical features
Supply by communication bus
Number of temperature levels 2 (DAY / NIGHT
Temperature setting range DAY 5 ÷ 30 °C
Temperature setting range NIGHT 5 ÷ 30 °C
Temperature setting range MANUAL 5 ÷ 30 °C
Differential operation temperature OFF 0.0 ÷ 1.0 °C
Differential operation temperature ON -1.0 ÷ -0.1 °C
Correct working range room temperature probe -40 ÷ 50 °C
Temperature resolution 0.1 °C
Room anti-frost start temperature range 0.1 ÷ 10.0 °C
Room anti-frost end temperature start value + 0.6 °C
Timer programmer resolution 30 minutes
Maximum number of startings and shutdowns per day 48
Number of standard heating programs 1
Number of standard storage tank programs 1
Internal clock time retention in case of power loss 1 ora
Operating temperature range 0 ÷ 50 °C
Stocking ambient temperature -10 ÷ 50 °C
Size (L×H×D 118×85×30 mm
Maximum cable length for boiler connection 50 mt
Cable section for boiler connection 0,5 ÷ 1,5 mm2

GENERAL INFORMATION
Dear customer,
Our compliments for buying the remote control device EASYREMOTE, a
product of latest technologies which will give you superior comfort.
In order to get top performance and to learn how to best use features
and functions of this remote control device, carefully read this manual
and keep it always readily accessible in case you need to refer to it.
CAUTION
Before connecting refer to the Instruction booklet to make
sure that the boiler was designed to be used with the
remote control device EASYREMOTE

GENERAL INFORMATION
A Select operation status
B Set time and temperature
C Weekly program
D Change displayed value (turn Select automatic / manual (press
E Alarm reset
F Select temperature level (day/night
G Temperature display

GENERAL INFORMATION
LCD symbols
ICON STEADY BLINKING
Current temperature Fault code
Time/temperature
Current day of the week Change day of the week
Domestic hot water
enabled
Domestic hot water
requested
Heating enabled Heating requested
Manual mode
Burner on
Heating program Change heating program
Storage tank program Change storage tank
program
Current room set point Temporary change room
set point
Outside temperature
System pressure
Set time and day of
the week
Set day temperature
Set night temperature
Heating temperature Set heating temperature
Domestic hot water
temperature
Set domestic hot water
temperature
kd value
Current temperature
level = day
Current temperature
level = night
Fault, no more attempts
left for restoring
Fault - restore attempts
available
Fault requiring technical
service
Night level
Day level

CONTENTS
1. How to use this instruction booklet ………...…………….………………..…1
2. General instructions.………………………………………………………...…..2
3. Main features…………………………………………………………..………...3
4. Installation….……………………………………………………………..……...4
5. Configurating operating parameters………..………………………………….8
6. Disabling thermo-regulation…………………………………………………..12
7. Boiler configuration (TSP)…… ………………………………………….…...13
8. Selecting operating mode……………….…………………………………….14
9. Setting up clock and temperature…..………………………………………..17
9.1. Setting up clock…………………………………………………………18
9.2. Setting up room DAY temperature……………………………….......20
9.3. Setting up room NIGHT temperature…………………………….......21
9.4. Setting up HEATING temperature…………………………………….22
9.5. Setting up DOMESTIC HOT WATER temperature ………………...23
9.6. Setting up outside probe KD value…………………………….……..24
10.Setting up clock and temperatures…………………………………………..26
10.1. MANUAL operation……………………………………………………..27
10.2. AUTOMATIC operation…………………………………………...……28
11.Weekly heating program………………………………………………..…….29
11.1. Display heating program………………………………………….……30
11.2. Change heating program………………………………………...…….31
12.Weekly storage tank program……………………………………………..…32
12.1. Display storage tank program…………………………………….......33
12.2. Change storage tank program……………………………………......34
13.Temporary change room temperature set point……………………………35
14.Fault signalling…………………………………………………………………36
14.1. Restorable faults………………………………………………………..36
14.2. Not restorable faults ……………………………………………….......37
15.Display values………………………………………………………………....38
15.1. Display set room temperature…………………………………….......39
15.2. Display temperature domestic hot water probe……………….…….39
15.3. Display temperature delivery probe ………………………………….40
15.4. Display temperature outside probe…………………………….……..40
16.Reset of default values …………………………………………………........41
17.Complete resetting………………………………………………………….…43
18.Room anti-freeze function…………………………………………………….44

INSTALLER INSTRUCTIONS
1
1. How to use this instruction book et
This booklet is divided into two sections, each of which having its own
addressee:
•
Insta er section, this gives instructions regarding the accurate
installation and configuration of the remote control device.
•
User section, this gives detailed instructions regarding the steps to
carry out in order to personalize the functioning of the EASYREMOTE
remote control device.
Some hints
•
When a numeric value is blinking you can change it by turning button
.
•
The value as changed by turning button will be automatically
stored when the blinking stops.
The use of the symbol shows the impossibility to dispose
this product as domestic waste.
The correct disposal of this product helps to prevent
potential negative consequences for the environment and
human health.

INSTALLER INSTRUCTIONS
2
2. Genera instructions
•
Carefully read this manual because it will give you important
instructions regarding the safety of use, installation and maintenance.
•
The system must be implemented in compliance with the safety
regulations in force.
•
After unpacking and before installing check that the product is intact.
•
This device is to be used only for the use it has been designed for: any
different use is improper.
•
In case of repair contact only technical service centers authorized by
the manufacturer.
•
Non-compliance with the above may endanger the safety of the
device.
•
If the device is installed to control a low temperature zone, this zone
must be equipped with a low temperature safety thermostat
surveying it.
•
The manufacturer cannot be held liable for any damages resulting
from bad operation, extraordinary events, configuration errors or
improper, wrong and unreasonable use of the device.
•
The manufacturer reserves the right to eventually make changes to
the device and whatever else appears necessary for the continual
improvement thereof.

INSTALLER INSTRUCTIONS
3
3. Main features
The EASYREMOTE remote control device has been designed to
guarantee ideal temperature conditions at any moment of the day
offering the possibility to set the boiler from remote.
The programming of the EASYREMOTE remote control device is
extremely easy a large LCD-display makes it possible to check and
change the set values at any time.
The EASYREMOTE remote control device is electrically connected to
the boiler by means of two nonpolarized conductors.
They give it the necessary supply to operate and constitute also the
communication between the two devices.
After installing it is immediately ready to run with its memorized
standard program.
This program can be changed according to the needs of the user.
Table des matières
Autres manuels Radiant Télécommande
Manuels Télécommande populaires d'autres marques

Panasonic
Panasonic EUR7622KB0 Manuel utilisateur

Bang & Olufsen
Bang & Olufsen Beo4 Manuel utilisateur

Sunwave Tech.
Sunwave Tech. RemoteComm SRC-7000 Manuel utilisateur

Multiplex
Multiplex PROFI TX 9 Manuel utilisateur

One Remote
One Remote RMB4 Manuel utilisateur

FUTABA
FUTABA 9ZAP - PART2 Manuel utilisateur