Qvis DoorProtect Manuel utilisateur

DoorProtect User Manual
Updated June 30, 2020
DoorProtect is a wireless door and window opening detector designed for
indoor use. It can operate up to 7 years from a pre-installed battery and capable
to detect more than one million openings. DoorProtect has a socket for
connecting an external detector.
The functional element of DoorProtect is a sealed contact reed relay. It consists of
ferromagnetic contacts placed in a bulb that form a continuous circuit under the effect
of a constant magnet.
DoorProtect operates within the Ajax security system, connecting via the
protected radio protocol. Communication range is up to 1,200 m in the
line of sight. Using the or integration modules,
DoorProtect can be used as part of third party security systems.
The detector is set up via for iOS, Android, macOS and Windows. The
app noties user of all events through push notications, SMS and calls (if
activated).
Jeweller
uartBridge ocBridge Plus
Ajax apps

The Ajax security system is self-sustaining, but the user can connect it to the
central monitoring station of a private security company.
Functional Elements
Operating Principle
Buy opening detector DoorProtect
1. DoorProtect
2. Big magnet
3. Small magnet
4. LED indicator
5. SmartBracket attachment panel (perforated part is required for actuating
the tamper in case of any attempt to dismantle the detector. Don’t break it
out!)
6. External detector connection socket
7. QR code
8. Device switch
9. Tamper button

DoorProtect consists of two parts: the detector with a sealed contact reed relay,
and the constant magnet. Attach the detector to the door frame, while the
magnet can be attached to the moving wing or sliding part of the door. If the
sealed contact reed relay is within the coverage area of the magnetic eld, it
closes the circuit, which means thatthe detector is closed. The opening of the
door pushes out the magnet from the sealed contact reed relay and opensing
the circuit In such a way, the detector recognizes the opening.
A small magnet works at a distance of 1 cm, and the big one — up to 2 cm.
After actuation, DoorProtect immediately transmits the alarm signal to the hub,
activating the sirensand notifying the user and security company.
Pairinging the Detector
Before starting pairing:
Only users with administor rights can add the device to the hub.
How to pair the detector with the hub:
1. Following the hub instruction recommendations, install the on your
smartphone. Create an account, add the hub to the app, and create at least
one room.
Ajax app
2. Switch on the hub and check the internet connection (via Ethernet cable
and/or GSM network).
3. Make sure that the hub is disarmed and does not update by checking its
status in the app.
1. Select theAdd Device option in the Ajax app.

For detection and pairing to occur, the detector should be located within the
coverage area of the wireless network of the hub (at a single protected object).
The request for connection to the hub is transmitted for a short period of time at
the moment of switching on the device.
2. Name the device, scan/write manually the QR Code (located on the body
and packaging), and select the location room.
3. SelectAdd— the countdown will begin.
4. Switch on the device.

If pairing with the hub failed, switch off the detector for 5 seconds and retry it.
If the detector has paired with the hub,it will appear in the list of devices in the
Ajax app. The update of the detectors statuses in the list depends on the
detector ping interval set in the hub settings. he default value is 36 seconds.
Connecting to Third-Party Systems
To connect the detector to a third-party security central unit using the
or integration modules, follow the recommendations in the user
manual of the respective device.
States
uartBridge
ocBridge Plus
1. Devices
2. DoorProtect

Parameter Value
Temperature
The temperature of the detector. The
temperature is measured on the processor and
changes gradually
Jeweller Signal Strength The signal strength between the hub and the
detector
Connection The connection status between the hub and the
detector
Battery Charge The battery level of the detector, displayed in
increments of 25%
Lid The tamper state, which reacts to detachment
or damaging of the detector body
Delay When Entering, sec The delay time when entering
Delay When Leaving, sec The delay time when exiting
Routed Through Rex Indicates if the detector is routed through a
radio signal range extender
Primary Detector The primary detector status
Secondary Detector The status of the external detector connected
to DoorProtect
Always Active If active, the detector is always in the armed
mode
Firmware The detector rmware version
Device ID The device identier

Setting Up
Setting Value
First eld The detector name, can be edited
1. Devices
2. DoorProtect
3. Settings

Room Selecting the virtual room to which the device is
assigned
Delay When Entering, sec Setting the delay time when entering
Delay When Leaving, sec Setting the delay time on exit
Delays in night mode Delay turned on when using night mode
Arm in Night Mode If active, the detector will switch to the armed
mode when using the night mode
Primary Detector If active, DoorProtect primarily reacts to
opening/closing
External Сontact Enabled If active, the detector registers external detector
alarms
Always active If active, the detector always registers
opening/closing
Activate the siren if the door or window is open If active, and are
activated when the opening detected
Activate the siren if an external contact opened If active, HomeSiren and StreetSiren are
activated during an external detector alarm
Jeweller Signal Strength Test Switches the detector to the signal strength test
mode
Detection Zone Test Switches the detector to the detection area test
Attenuation Test
Switches the detector to the signal attenuation
test mode (available for detectors with
rmware version 3.50 and later)
User Guide Opens the detector User Guide
Unpair Device Disconnects the detector from the hub and
deletes its settings
Indication
Event Indication Note
Switching on the detector Lights up green for about one
second
Detector connecting to the
, and Lights up for a few seconds
HomeSiren StreetSiren
hub ocBridge Plus
uartBridge

Alarm / tamper activation Lights up green for about one
second
Alarm is sent once in 5
seconds
Battery needs replacing
During the alarm, it slowly
lights up green and slowly
goes out
Replacement of the detector
battery is described in the
manual
Functionality Testing
The Ajax security system allows conducting tests for checking the functionality
of connected devices.
The tests do not start immediately but within 36 seconds by default. The
starting time depends on the ping interval (the paragraph on “Jeweller” settings
in hub settings).
Installing the Detector
Selecting the location
Location of DoorProtect is determined by its remoteness from the hub and
presence of any obstacles between the devices hindering the radio signal
transmission: walls, inserted oors, large objects located within the room.
Check the signal level at the installation location
If the signal level is low (one bar), we cannot guarantee stable operation of the
security system. Take all possible measures to improve the quality of the signal!
As a minimum, move the device — even 20 cm shift can signicantly improve
the quality of the reception.
Battery Replacement
Jeweller Signal Strength Test
Detection Zone Test
Attenuation Test

If, after moving, the device still has a low or unstable signal strength, use the
.
The detector is located either inside or outside of the door case (window frame):
When installing the detector in the perpendicular planes (inside the case/frame),
use the small magnet. The distance between the magnet and detector should
not exceed 1 cm.
When positioning the parts of DoorProtect in the same plane, use the big
magnet. Its actuation threshold — 2 cm.
Attach the magnet to the moving part of the door (window) to the right of the
detector. If necessary, the detector may be overturned or positioned horizontally.
Installing the detector
Before installing the detector, make sure that you have selected the optimal
location and it complies with the guidelines of this manual!
ReX radio signal range extender
Table des matières