QuietCool IT-AF-SMT Manuel utilisateur

OWNER’S GUIDE
SMART ATTIC FAN CONTROL
IT-AF-SMT

1-888-QUIETCOOL
2
CONTENTS
1. SYSTEM OVERVIEW . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
1.1 Introduction . . . . . . . . . . . . . . . . . . . . . . . . 3
1.2 Features . . . . . . . . . . . . . . . . . . . . . . . . . . .3
1.3 KeySpecications...................3
1.4 Warnings . . . . . . . . . . . . . . . . . . . . . . . . . . 3
2. INSTALLATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
2.1 Installing the Hub . . . . . . . . . . . . . . . . . . . 4
3. WIRING . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
3.1 One Speed Wiring . . . . . . . . . . . . . . . . . . . 4
3.2 Two Speed Wiring . . . . . . . . . . . . . . . . . . . 5
3.3 Three Speed Wiring . . . . . . . . . . . . . . . . . .6
3.4 Smart Control Hub - LED Indicators . . . . . 7
4. SYSTEM OPERATING INSTRUCTIONS . . . . . . . . . . . . .8
4.1 Download Smart Control App . . . . . . . . . .8
4.2 Operating the Smart Control App . . . . . . 8
4.3 Frequently Asked Questions . . . . . . . . . . .16
4.4 Safety . . . . . . . . . . . . . . . . . . . . . . . . . . . . .16
WARRANTY. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .19
QC MANUFACTURING, INC.
26040 YNEZ ROAD
TEMECULA, CA 92591
PHONE 1-888-QUIETCOOL
WEBSITE WWW.QUIETCOOLSYSTEMS.COM

QUIETCOOLSYSTEMS.COM
3
1. SYSTEM OVERVIEW
1.1 INTRODUCTION
CONGRATULATIONS
on the purchase of your new QuietCool Smart Attic Fan Control!
The QuietCool Smart Attic Fan Control is the smartest way to
control your QuietCool Advanced Attic Fans!
The QuietCool Smart Attic Fan Control allows users to control their
attic fan, activate smart mode, and adjust the settings of their attic
fan from our innovative phone app.
1.2 FEATURES
Smart Mode with temperature and humidity settings to keep
your attic at the optimum temperature and humidity level
Set countdown time for your QuietCool attic fan (up to 12 hours)
Adjust speed setting for your QuietCool attic fan
Integratedrefusethatautomaticallyshutsofffanatover182ºF
WELCOME INSTALLATION WIRING OPERATION WARRANTY
1.3 KEY SPECIFICATIONS
IT-AF-SMT Hub
Voltage: 120V
Frequency: 60Hz
Motor load: 1HP, 735W (Max)
UL Rated Operating Temp: 14°F - 149°F
Thelistingofthisproductallowsittobeinstalledinconned
spaces with temperatures that exceed 120° F.
1.4 WARNINGS
CAUTION: Automatically started device. To reduce the risk
of injury, disconnect from power supply before servicing. For
residential use only.

1-888-QUIETCOOL
4
2. INSTALLATION
2.1 INSTALLING THE HUB
IMPORTANT: If you are installing the Hub onto an existing fan, be sure to shut off the power
before attempting installation. If you are installing the Hub onto a new fan, perform all
installation steps before plugging in the fan.
1. Open up the thermostat on your attic fan. Unwire the power cord and remove the plastic
connector.Unwirethemotorwiresandremovethemetalconnectorandexfrom
the thermostat.
2. AttachthemetalconnectorandextooneoftheknockoutsontheIT-AF-SMThub.Attach
the plastic power cord bushing in another knockout on the hub.
3. WIRING
NOTE: Wiring Diagrams are for examples ONLY. Wiring should be done by an
experienced electrician.
3.1 ONE SPEED WIRING
1. Using a wire nut, connect the black wire from the power cord to the black wire from the Hub.
2. Connect the white wire from the power cord and the white wire on the fan to the white wire
from the Hub.
3. Connect the black wire from the fan to the blue wire on the Hub.
4. Cap the red wire on the Hub. Cap the yellow wire from the Hub.
5. Ground the green wire from the fan and the green wire from the power cord to the ground
screw in the Hub.
Figure 3.1A

QUIETCOOLSYSTEMS.COM
5
6. Set the dip switch positions inside the Hub as shown in the Figure 3.1A.
7. Power-on the Hub. The Power LED indicator will be lit.
8. Press the Test button to make sure the fan works. The Test LED indicator will blink three times
every two seconds indicating 1-speed and the fan will be on. Press the Test button again and
the fan should shut off and the LED will be off.
9. If the fan doesn’t operate as described in step 9, please check the dip switch position.
3.2 TWO SPEED WIRING
1. Using a wire nut, connect the black wire from the power source to the black wire from
the Hub.
2. Connect the white wire from the power source and the white wire on the fan to the white
wire from the Hub.
3. Connect the black wire from the fan to the blue wire on the Hub.
4. Connect the red wire from the fan to the red wire on the Hub.
5. Cap the yellow wire from the Hub.
6. Ground the green wire from the fan and the green wire from the power cord to the ground
screw in the Hub.
7. Set the dip switch positions inside the Hub as shown in the Figure 3.2A.
8. Power-on the Hub. The Power LED indicator will be lit.
9. Press the Test button to make sure the fan works. The Test LED indicator will blink three
times every two seconds indicating 2-speed and the fan will be on high. Press the Test button
again and the fan will switch to low speed and the Test LED indicator will blink once every
two seconds. Press the Test button again and the fan should shut off and the LED will be off.
10. If the fan doesn’t operate as described in step 9, please check the dip switch position/wiring.
Figure 3.2A
WELCOME INSTALLATION WIRING OPERATION WARRANTY

1-888-QUIETCOOL
6
3.3 THREE SPEED WIRING
1. Using a wire nut, connect the black wire from the power cord and the black wire from the fan
to the black wire from the Hub.
2. Connect the white wire from the power cord and the white wire on the fan to the white wire from
the Hub.
3. Connect the red wire from the fan to the red wire on the Hub.
4. Connect the yellow wire from the fan to the yellow wire on the Hub.
5. Connect the blue wire from the fan to the blue wire on the Hub.
6. Ground the green wire from the fan and the green wire from the power cord to the ground
screw in the Hub.
7. Set the dip switch positions inside the Hub as shown in Figure 3.3A.
8. Power-on the Hub. The Power LED indicator will be lit.
9. Press the Test button to make sure the fan works. The Test LED indicator will blink three times every
two seconds indicating 3-speed and the fan will be on high. Press the Test button again and the
fan will switch to medium speed and the LED will blink twice every two seconds. Press the Test
button again and the fan will switch to low speed and the LED will blink once every two seconds.
Press the Test button again and the fan should shut off and the LED will be off.
10. If the fan doesn’t operate as described in step 9, please check the dip switch position/wiring.
Figure 3.3A

QUIETCOOLSYSTEMS.COM
7
3.4 SMART CONTROL HUB - LED INDICATORS
• POWER Indicator
• The Power LED indicator will always be lit when the Hub is connected to Power.
• If this LED is not lit, check the power source.
• Temp and Hum | Timer Indicator
• This LED indicator will light up as shown below:
• Blinking: Timer Mode Active
• Solid: Smart Mode Active
• Test Indicator
• The Test LED indicator will light up as shown below when the Test button is
pressed:
• Two Speed Fan: blink three times every 2 seconds on HIGH, blink
once every 2 seconds on LOW
• Three Speed Fan: blink three times every 2 seconds on HIGH, blink
twice every 2 seconds on MED, blink once every 2 seconds on LOW
• Pair Indicator
• The Pair LED indicator will blink when making pair operations. Please see
SETTING UP YOUR FAN on page 12 for details on pairing.
• The indicator will be lit up solid when a device is connected via Bluetooth.
• The indicator will not be lit when no pairing operations are being made or no
device is connected.
WELCOME INSTALLATION WIRING OPERATION WARRANTY

1-888-QUIETCOOL
8
4. SYSTEM OPERATING INSTRUCTIONS
4.1 DOWNLOADING THE QUIETCOOL SMART CONTROL APP
Download the QuietCool Smart Control App onto your iOS or
Android device.
Scan the QR code above or visit QuietCoolSystems.com/smart-control/
and click the link to download the app to your device.
4.2 OPERATING THE QUIETCOOL SMART CONTROL APP
HOME PAGE
This is the home page of the app and is presented as
soon as the app is opened.
If you have not yet paired your phone to your Hub, it
will state SETUP REQUIRED.
If you have paired your phone to your Hub, it will
show a picture of the fan as well as the name of
your fan.
FAN SETUP PAGE
Thispageisusedtosetupthefanforthersttime.
You can quickly change the Fan Name, check if the
speeds are set properly, change the Fan Model,
enter the Serial Number and adjust the Climate
Settings & Presets.
These settings can be accessed again after setup
is done by clicking the Settings button on the Fan
Control Page.

QUIETCOOLSYSTEMS.COM
9
FAN CONTROL PAGE
This page is accessed when you tap on your fan
from the Home Page.
On this page you can see the current conditions in
your attic, activate the different modes of the fan,
and get to the Fan Settings page.
FAN SETTINGS PAGE
This page is used to adjust the settings of the fan.
You can quickly change the Fan Name, check if the
speeds are set properly, change the Fan Model,
enter the Serial Number and adjust the Climate
Settings & Presets.
You can also enter Pair Mode for remote pairing
of devices, perform a Firmware Update, as well as
reset all settings to factory defaults.
WELCOME INSTALLATION WIRING OPERATION WARRANTY

1-888-QUIETCOOL
10
SETTING UP YOUR FAN
Once your attic fan has power, open up the QuietCool
Smart Control app. You will be taken to the Home Page.
You should see your attic fan show up in the list of available
fans.
A message indicates that setup is required. Press and hold
the Pair button on the Hub until the LED indicator begins
to blink.
NOTE: You will need to initiate this Pairing process
on each device you want to use to control your attic
fan. Once the initial device is paired, you can use the
“Enter Pair Mode” function from the app described
on page 16. This will prevent you from having to
access the Hub physically in the attic in order to
perform pairing operations.
Tap on the fan to start the setup process. Once you tap on
the fan, you will be taken to the Fan Setup page.
On this page, you will be able to change the following
settings:
• Fan Name
• Fan Model
• Serial Number
The Speeds Available section will tell you if you have
connected the fan and set your dip switch properly.
Makesurethatthisnumbermatchesthespecicationof
the fan you purchased.
In this example, we are setting up an AFG SMT PRO-2.0
which is a 2-speed fan.
The QuietCool Smart Attic Fan Control has an innovative
Smart mode that allows the fan to adjust the speed based
on the temperature and humidity conditions in your attic.
Tap Climate Settings & Presets to adjust these settings.
Within this mode there are two standard presets, Summer
and Winter. You can modify these presets and add your
own custom presets to allow quick setting changes on
they.
Autres manuels pour IT-AF-SMT
3
Table des matières
Autres manuels QuietCool Contrôleurs