Pylon Technologies BP Series Manuel utilisateur

1
BP Series
Lithium-Iron Phosphate Battery Backup
Product Manual
Information Version: 1.0
Pylon Technologies Co., Ltd.
No. 73, Lane 887, Zu Chongzhi Road, Zhangjiang Hi-Tech Park
Pudong, Shanghai 201203, China
Zip Code: 201203
Phone: 021-51317699
Fax: 021-51317698
URL: http://www.pylontech.com.cn
E-mail: service@pylontech.com.

2
LEGAL NOTICES
Copyright of Pylon Technologies Co., Ltd. Enjoin from abstracted reproduced or translated
by any unit or individual in any way without the written permission.
Rights Reserved.
The trademarks of Pylon Technologies Co., Ltd are
and . The names and logos of products from Pylontech are exclusive
belongs to Pylon Technologies Co., Ltd, proprietary marks or registered trademarks. Other
products or company names mentioned in this manual may be belonging to trademarks of
their respective owners or tradenames. Without the prior written consent of the Pylontech
or third party trademarks or owners of tradenames, this manual does not confer the
license or right by the reader to use any mark appeared on this manual in any way.
This product accord with the design requirements of environmental protection and
personal security, product storage, using and disposal should be in accordance with
product manuals, relevant contract and national laws.
When required product updates or technical changes, you can visit website of Pylontech
for the latest information, URL: http://www.pylontech.com.cn, without notice if the product
improvements or technical change in other way.
Information Version: V1.0
Information Number: MKT-BPSC1-201201

3
Introduction
Manual Explains
BP series (V1.3) lithium iron phosphate battery is power module for backup system and
energy storage system. In backup power system, the main power provides energy for
equipment and charging the battery; when power off, battery provides energy. While in
energy storage system, battery charging or discharging can be managed by system,
users can choose energy from solar panel, main power or battery, it saves energy cost.
BP series Product Manual exposited the basic processes and methods of the device,
includes structure, parameters, installation and operation. The main content following:
Chapter
Abstract
Chapter 1 Introduction
Main application and features of BP48100
Chapter 2 Structure and
Parameters
External structure, panel description, management module
parameters and others
Chapter 3 Installation and
Collocation
Product installation, network usage and requires attention in
installation process of BP48100
Chapter 4 Maintenance and
Troubleshooting
Common operating state descriptions and Troubleshooting of
BP48100
Safety Instructions
This device only be installed, operated and maintained by people who professional trained
and qualified. In the process of installation, operation and maintenance, local safety
regulations and related procedures must be complied, or it may cause injury or equipment
damage. Safety precautions mentioned in manual only as a supplement for local safety
regulations. Pylontech does not assume any responsibility for breaching common security
operation or equipment safety standards.
Symbols
The following format described some contents need attention for BP series
Note: If warning ignored, the product may malfunction.

4
Catalogue
1 INTRODUCTION...............................................................................................................................1
1.1 Introduction.......................................................................................................................... 1
1.2 Product Features................................................................................................................ 1
2 STRUCTURE AND PARAMETER................................................................................................. 3
2.1 Equipment Structure.......................................................................................................... 3
2.1.1 Equipment Model............................................................................................................... 3
2.1.2 Equipment Front Interface Instruction............................................................................ 4
2.2 Battery Management System(BMS).......................................................................... 7
2.2.1 Voltage Protection.............................................................................................................. 7
2.2.2 Current Protection.............................................................................................................. 7
2.2.3 Additional Protection Features.........................................................................................7
2.3 Charge Parameters............................................................................................................8
2.4 Discharge Parameters....................................................................................................... 8
3 INSTALLATION AND CONFIGURATION....................................................................................9
3.1 Installation Preparation......................................................................................................9
3.1.1 Environmental Requirements........................................................................................ 10
3.1.2 Tools and Information...................................................................................................... 11
3.1.3 Technical Preparation...................................................................................................... 11
3.1.4 Unpacking......................................................................................................................... 12
3.1.5 Project Coordination........................................................................................................12
3.2 Equipment Installation..................................................................................................... 13
3.2.1 Mechanical Installation....................................................................................................13
3.2.2 Electrical Installation........................................................................................................14
4 USING, MAINTENANCE AND TROUBLESHOOTING............................................................19
4.1 Alarm Description and Processing................................................................................ 19
4.1.1 The Alarm and Countermeasure Influence System Output..................................19
4.1.2 The Alarm and Countermeasure do not Influence System Output..................... 19
4.2 Common Fault Analysis and Solutions.........................................................................20

5
Catalogue of Diagrams
Figure 2-1 Sketch of BP series Product Front Interface................................................. 4
Figure 3-1 Schematic of Installation Process:.............................................................. 10
Figure 3-2: Schematic of Device Fixed to the Cabinet................................................14
Figure 3-3 Multiple Batteries in Parallel Power Line Connection Diagram:.............15
Figure 3-4 Connection Diagram Interface between Battery and Load Equipment of
DC Backup Power..............................................................................................................16
Figure 3-5 Battery and Switch Power Connection Diagram.......................................16
Figure 3-6 Cascading of Multiple Batteries in Parallel Network Schematic.............17

6
Catalogue of Table
Table2-1 BP series Equipment Model............................................................................3
Table 2-2 Definition of RS232 Port Pin.........................................................................5
Table 2-3 ADD Switch......................................................................................................5
Table 2-4 LED Indicators Instructions...........................................................................6
Table 2-5 Charging Parameters.....................................................................................8
Table 2-6 Discharging Parameters................................................................................8
Table 3-1 Tools and Meters.......................................................................................... 11
Table 3-2 Installation Steps.......................................................................................... 13
Table 4-1 Major Alarm and Protection........................................................................ 19
Table 4-2 Secondary Alarm.......................................................................................... 20
Table 4-3 Common Faults and Solutions...................................................................20

1
1Introduction
1.1 Introduction
BP series lithium iron phosphate battery are new energy storage products
developed and produced by Pylontech according to market demand, it can be used
to provide reliable power for various types of equipment and solar systems. BP
series are especially suitable for application scene of high temperature, limited
installation space, light load-bearing and long cycle life.
BP series has built-in BMS battery management system, which can manage and
monitor cell information including voltage, current and capacity. What’s more, BMS
can balance cells charging and discharging and extend cycle life. Multiple batteries
can be connected for larger capacity in parallel for longer duration backup
requirements.
1.2 Product Features
BP series product from Pylontech is using lithium iron phosphate as cathode
material, with BMS for effective management of cells. The module has following
characteristics:
New: Updated the MCU and AFE chips, has stronger anti short circuit and
reversed connection function. It will lower the fuse or MOSFET failure;
New: 1 group can maximum 16 batteries connected in;
New: More memory capacity, now it is 12288 records (before was only 4096
records).
The whole module is non-toxic, non-polluting and environmentally friendly;
Cathode material is made from LiFePO4 which has safety performance and long
cycle life;
Battery management system (BMS) has protection function for over-discharge,

2
over-charge, over-current and high/low temperature;
The system can automatically manage charge and discharge state and balance
current and voltage of each cell;
The centralized monitoring module is intelligent designed with three remote
functions of test, signal and control;
Flexible configuration achieved that several battery modules can be in parallel for
expanding capacity and backup duration;
Adopted self-cooling mode rapidly reduced system entire noise;
Battery has less self-discharge, without charge up to 10 months; no memory effect,
can be floating charge and discharge;
Working temperature range is from -10 ℃to 50 ℃, with excellent discharge
performance and cycle life in high temperature;
Small size and light weight, standard of 19-inch embedded designed module is
comfortable for installation and maintenance;

3
2Structure and Parameter
2.1 Equipment Structure
2.1.1 Equipment Model
BP4850
BP48100

4
Table2-1 BP Series Equipment Model
Product
Series
Model
Rated
Voltage
Rated
Capacity
Size
Weight
BP Series
BP4850
48V
50Ah
442×380×88.5mm
24kg
BP Series
BP48100
48V
100Ah
442×385×176mm
45kg
2.1.2 Equipment Front Interface Instruction
This section details the front panel of the interface functions.
Figure 2-1 Sketch of BP series Product Front Interface
Power Port (1)
Power cord connection: the same function of two power interface in parallel.
Each interface from top to bottom is anode and cathode. For each single cell,
any interface can achieve charging and discharging function.
Reset (2)
Shut down button: When the battery is in storage, transportation and other
non-using state, press the button to shutdown. If there is no external load or
external power supply for 10 hours, it will automatically shutdown.
Communication Interface (3, 4, 5, 6)
Dry Contact (DO).
RS232 port (No. 4, Figure 2-1): The interface is for the local network
management, but can also be the docking tube interface of network with ONU
equipment from ZTE.
Ce manuel convient aux modèles suivants
2
Table des matières