PVI MTRX Manuel utilisateur

Digital Tuner Streamer
This Manual Apply to the MTRX 4/8 Tuner To IPTV Systems
On 8 Tuners Systems, The inputs are all assigned to the 8 Tuners Only and no asi
Web-NMS Version: 1.03
Software: 1.00
Hardware: 0.40

4 in 1 IRD User’s Manual
DIRECTORY
Chapter 1 Product Outline ............................................................................1
1.1 Outline ....................................................................................................................1
1.2 Features..................................................................................................................1
1.3 Specifications .........................................................................................................2
1.4 Principle Chart........................................................................................................4
1.5 Appearance and description...................................................................................4
Chapter 2 Installation Guide .........................................................................6
2.1 Acquisition Check...................................................................................................6
2.2 Installation Preparation...........................................................................................6
2.3 Wire’s Connection ..................................................................................................8
2.4 Signal Cable Connection........................................................................................9
Chapter 3 Operation ....................................................................................11
3.1 LCD Menu Class Tree..........................................................................................11
3.2 General Setting.....................................................................................................14
Chapter 4 Web-based NMS Management ..................................................23
4.1 login......................................................................................................................23
4.2 Operation..............................................................................................................24
Chapter 5 Troubleshooting...............................Error! Bookmark not defined.
Chapter 6 Packing List ......................................Error! Bookmark not defined.

1 / 38
Chapter 1 Product Outline
1.1 Outline
MTRX IRD is PVI’s new design which integrates demodulation (DVB-C, T/T2, S/S2
optional), de-scrambler and multiplexing in one case to convert RFsignals into TS output.
It is a 1-U case which supports 4 tuner inputs, 1 ASI and 4 IP inputs. The 4 CAMs/CIs
accompanied can descramble the programs input from encrypted RF, ASI and IP. The
CAM requires NO unsightly external power cords, cables, or additional remote control
device.
To meet customers’ various requirements, MTRX is also designed to de-mux programs
from any input, and output TS over 48 SPTS.
1.2 Features
4 Tuner inputs (DVB-C, T/T2, S/S2 Optional)
1 ASI & 4 IP (UDP) input for de-mux
One CAM can decrypt multiple programs from Tuners/ASI/IP
IP (48 SPTS) over UDP and RTP/RTSP output;
4 groups of independent ASI out for tuner/IP passthrough (one-to-one)
Support maximum 128 PID mapping per input
LCD display, Remote control and Firmware, web NMS management
Updates via web
Best quality and breakthrough price

2 / 38
1.3 Specifications

4-in-1 IRD User’s Manual
3 / 38
Input
4x RF (DVB-C, T/T2, S/S2 optional), F type
1×ASI input for de-mux, BNC interface
4xIP input for de-mux (UDP)
Tuner Section
DVB-C
Standard
J.83A(DVB-C), J.83B,
J.83C
Input Frequency
47 MHz~860 MHz
Constellation
16/32/64/128/256 QAM
DVB-T/T2
Input Frequency
44MHz ~1002 MHz
Bandwidth
6/7/8 M
DVB-S
Input Frequency
950-2150MHz
Symbol rate
2-45Msps
Signal Strength
- 65- -25dBm
Constellation
1/2, 2/3, 3/4, 5/6, 7/8
QPSK
DVB-S2
Input
Frequency
950-2150MHz
Symbol rate
QPSK 1~45Mbauds;
8PSK 2~30Mbauds
Code rate
1/2, 3/5, 2/3, 3/4, 4/5, 5/6,
8/9, 9/10
Constellation
QPSK, 8PSK
Output
IP
48*SPTS over UDP, RTP/RTSP.
1000M Base-T Ethernet interface
(unicast / multicast)
ASI
4 groups BNC interface
System
Local interface
LCD + control buttons
Remote
management
Web NMS Management
Language
English
General
Power supply
AC 100V~240V
Dimensions
482*400*44.5mm
Weight
3 kgs
Operation
temperature
0~45℃

4-in-1 IRD User’s Manual
4 / 38
1.4 Principle Chart
IP (48 SPTS) Out
ASI Out 4
4 x CAM/CI
ASI Out 1
ASI Out 2
ASI Out 3
MUX
SAT RF 1
IP 1
SAT RF 2
IP 2
SAT RF 3
IP 3
SAT RF 4
IP 4
ASI
choose 4 channels from all inputs to descramble
CI 1 & 2 are designed to descramble tuner 1/2, ASI or IP 1-4.
CI 3 & 4 are designed to descramble tuner 3/4, ASI or IP 1-4.
1.5 Appearance and description
1
LCD Display
2
Indicators Area (Lock 1-4: they light up when the tuner signal
are properly connected. Descram 1-4: they light up when the
CI cards are properly inserted.
3
Up/Down/Left/Right Buttons
Enter Key for confirmation
Menu Key for backward
Lock Key
Rear Panel Illustration

4-in-1 IRD User’s Manual
5 / 38
1
CAM/CI Slots 1 & 2 (Applied to descramble tuner 1 & 2, ASI input
and IP input 1 to 4)
2
Tuner Input 1 & 2
3
CAM/CI Slots 3 & 4 (Applied to descramble tuner 3 & 4, ASI input
and IP input 1 to 4)
4
Tuner Input 3 & 4
5
ASI output groups 1-4
6
ASI input port for de-mux
7
NMS Port (connect to PC for device management)
8
DATA Port (for IP stream input & output, 1000M)
9
Power switch/Fuse/Socket/Grounding Wire

4-in-1 IRD User’s Manual
6 / 38
Chapter 2 Installation Guide
2.1 Acquisition Check
When user opens the package of the device, it is necessary to check items according
to packing list. Normally it should include the following items:
MTRX 4-in-1 IRD 1pcs
Power Cord 1pcs
If any item ismissing or mismatching with the list above, please contact our company.
2.2 Installation Preparation
When users install device, please follow the below steps. The details of installation
will be described at the rest part of this chapter. Users can also refer rear panel chart
during the installation.
The main content of this chapter including:
Checking the possible device missing or damage during the transportation
Preparing relevant environment for installation
Installing modulator
Connecting signal cables
Connecting communication port (if it is necessary)
2.2.1 Device's Installation Flow Chart Illustrated as following:
Connecting
Grouding
Wire and
Power
Cord
Acquisition
Check Fixing
Device Setting
Parameter Running
Device
Connecting
Signal Wire
2.2.2 Environment Requirement

4-in-1 IRD User’s Manual
7 / 38
Item
Requirement
Machine Hall Space
When user installs machine frame array in one
machine hall, the distance between 2 rows of machine
frames should be 1.2~1.5m and the distance against
wall should be no less than 0.8m.
Machine Hall Floor
Electric Isolation, Dust Free
Volume resistivity of ground anti-static material:
1X107~1X1010,Grounding current limiting
resistance: 1M (Floor bearing should be greater than
450Kg/㎡)
Environment
Temperature
5~40℃(sustainable ),0~45℃(short time),
installing air-conditioning is recommended
Relative Humidity
20%~80% sustainable 10%~90% short time
Pressure
86~105KPa
Door & Window
Installing rubber strip for sealing door-gaps and dual
level glasses for window
Wall
It can be covered with wallpaper, or brightness less
paint.
Fire Protection
Fire alarm system and extinguisher
Power
Requiring device power, air-conditioning power and
lighting power are independent to each other. Device
power requires AC power 100-240V 50-60Hz. Please
carefully check before running.
2.2.3 Grounding Requirement
All function modules’ good grounding is the basis of reliability and stability of
devices. Also, they are the most important guarantee of lightning arresting and
interference rejection. Therefore, the system must follow this rule.
Coaxial cables outer conductor and isolation layer should keep proper electric
conducting with the metal housing of device.

4-in-1 IRD User’s Manual
8 / 38
Grounding conductor must adopt copper conductor in order to reduce high
frequency impedance, and the grounding wire must be as thick and short as
possible.
Users should make sure the 2 ends of grounding wire well electric conducted and
be antirust.
It is prohibited to use any other device as part of grounding electric circuit
The area of the conduction between grounding wire and device’s frame should
be no less than 25mm2.
2.2.4 Frame Grounding
All the machine frames should be connected with protective copper strip. The
grounding wire should be as short as possible and avoid circling. The area of the
conduction between grounding wire and grounding strip should be no less than
25mm2.
2.2.5 Device Grounding
Connecting the device’s grounding rod to frame’s grounding pole with copper wire.
2.3 Wire’s Connection
The grounding wire conductive screw is located at the right end of rear panel, and the
power switch, fuse, power supply socket is just beside ,whose order goes like this,
power switch is on the left ,power supply socket is on the right and the fuse is just
between them.
Connecting Power Cord
User can insert one end into power supply socket, while insert the other end to
AC power.
Connecting Grounding Wire
When the device solely connects to protective ground, it should adopt
independent way, say, share the same ground with other devices. When the
device adopts united way, the grounding resistance should be smaller than 1Ω.
Caution:
Before connecting power cord to MTRX IRD, user should set the power switch
Table des matières