PROPOINT 9011495 Manuel utilisateur

V1.0 9011495
Please read and understand all instructions before use. Retain this manual for future reference.
.

9011495 Pen-Probe-Style Autoranging Digital Multimeter V1.0
2 For technical questions call 1-800-665-8685
Display 3-1/2 digit LCD with a maximum reading of 1,999
Polarity Auto polarity indication
Over-range Indication "OL" shown on the display
Sampling Rate 3 times per second
Power Single standard 9V battery
Low Battery Indication is displayed when the battery voltage drops
below the operating voltage
Auto Power Off If the meter is not operated for about 15 minutes, it
will turn off automatically and stay in Sleep mode.
Operating Temperature
0°C to 40°C, < 75%RH
Storage Temperature -20°C to 60°C, < 85%RH
Accessories 9V battery, owner's manual
FUNCTION
RANGE RESOLUTION
DC Voltage 200mV ± (0.5% + 2)
2V - 20V - 200V ± (0.7% + 2)
300V ± (0.8% + 2)
Input impedance: about 10M
Max. permitted input voltage: 300V DC
AC Voltage 2V ± (0.8% + 3)
20V - 200V ± (1.2% + 3)
300V ± (1.5% + 3)
Input impedance: about 10M
Frequency: 40Hz - 400Hz
Max. permitted input voltage: 300V AC

V1.0 Pen-Probe-Style Autoranging Digital Multimeter 9011495
Visit www.princessauto.com for more information 3
DC Current 20mA ± (1.2% + 3)
200mA
Max. permitted input current: 200mA DC, overcurrent will
blow the fuse
AC Current 20mA ± (1.5% + 5)
200mA
Frequency: 40Hz - 400Hz
Max. permitted input current: 200mA AC, overcurrent will
blow the fuse
Resistance 200 ± (1.2% + 3)
2k , 20k , 200k , 2M ± (1.0% + 2)
20M ± (2.0% + 2)
Diode test Open circuit voltage: approximately 1.5V
Test current: approximately 0.5mA
Audible
continuity Built-in buzzer sounds if resistance is less than 50 .
Built-in buzzer might sound if resistance is between 50 and
120 .
Built-in buzzer does not sound if resistance is greater
than 120 .
Please familiarize yourself with the hazard notices found in this manual.
A notice is an alert that there is a possibility of property damage, injury
or death if certain instructions are not followed.
DANGER! This notice indicates an immediate and specific hazard that
will result in severe personal injury or death if the proper
precautions are not taken.
WARNING! This notice indicates a specific hazard or unsafe practice
that could result in severe personal injury or death if the
proper precautions are not taken.
CAUTION! This notice indicates a potentially hazardous situation that
may result in minor or moderate injury if proper practices are
not taken.

9011495 Pen-Probe-Style Autoranging Digital Multimeter V1.0
4 For technical questions call 1-800-665-8685
NOTICE! This notice indicates that a specific hazard or unsafe
practice will result in equipment or property damage, but
not personal injury.
This compact digital multimeter is used for measuring DC and AC
voltage, DC and AC current, resistance, diode, continuity, and logic level.
This meter was designed for the homeowner, hobbyist, and professional
needing to make electrical and electronic equipment measurements.
WARNING! Read and understand all instructions before using this
tool. Keep this manual for the safety warnings and precautions,
operating, inspection and maintenance instructions. When using
this tool, basic precautions should always be followed to reduce
the risk of personal injury and/or damage to the equipment. Note
that when this manual refers to a part number, it refers to the
parts list included. Before allowing someone else to use this tool,
make sure they are aware of all safety information.
1. Keep your work area clean and well lit. Cluttered and dark areas
invite accidents.
2. Operate in a safe work environment. Do not use machines or air
tools in damp or wet locations. Do not expose to rain.
3. Keep children, bystanders and visitors away from the work area. Do
not let them handle tools or extension cords. No one should be in
the work area if they are not wearing suitable protective equipment.
4. Store unused equipment. When not in use, tools must be stored in
a dry location to prevent rust. Always lock up tools and keep them
out of reach of children.
1. Dress properly, wear protective equipment.
2. Do not over reach; keep proper footing and balance at all times.
Proper footing and balance enables better control of the tool in
unexpected situations.

V1.0 Pen-Probe-Style Autoranging Digital Multimeter 9011495
Visit www.princessauto.com for more information 5
3. Stay alert, watch what you are doing and use your common sense.
Do not operate any machine or tool when you are tired, under the
influence of drugs, alcohol or medications.
This meter has been designed according to IEC-61010 concerning
electronic measuring instruments with a measurement category III (CAT
III 300V) and pollution degree 2. Measuring Category III (CAT III) is for
measurement performed on circuits directly connected to low voltage
installation (for example, measurements on household appliances,
portable tools, and similar equipment). Do not use this meter for
measurements within Measurement Category IV.
WARNING! To avoid possible electric shock or personal injury,
follow these guidelines:
1. Ensure that the batteries are correctly placed in the battery case
and connected properly.
2. Do not operate the meter with the battery cover or portions of the
case removed or loosened.
3. Do not use the meter if it is damaged. Before you use the meter,
inspect the case. Inspect the test leads for damaged insulation or
exposed metal. Check test lead continuity. Damaged leads should
be replaced.
4. Do not use the meter if it operates abnormally. Protection may be
impaired. When in doubt, have the meter serviced an authorized
service center.
5. Do not operate the meter around explosive gas, vapor, or dust.
6. Do not apply a voltage or current higher that the selected range’s
upper limit between terminals.
7. Before use, verify the meter’s operation by measuring a known voltage.
8. When measuring current, turn off power to the circuit before
connecting the meter to the circuit. Remember to place the meter
in series with the circuit.
9. Use caution when working above 30V AC rms, 42V peak, or 60V
DC. Such voltages pose a shock hazard.

9011495 Pen-Probe-Style Autoranging Digital Multimeter V1.0
6 For technical questions call 1-800-665-8685
10. Do not touch any naked conductor with hand or skin and do not
ground yourself.
11. Connect the black test lead before connecting the red test lead. When
disconnecting test leads, always disconnect the red test lead first.
12. Remove the test leads from the meter before opening the battery
cover or the case.
13. Replace the battery as soon as the low battery indicator appears
on the LCD display.
CAUTION! To avoid possible damage to the meter or to the
equipment under test, follow these guidelines:
1. Disconnect circuit power and discharge all capacitors before
measuring resistance or continuity.
2. Select the proper function and range for your measurement.
3. Before measuring current, turn off the power to the circuit before
connecting the meter to the circuit.
4. Before rotating the range switch to change functions, disconnect
the test leads from the circuit under test.
5. Remove the test leads from the meter before opening the battery
cover or the case.
6. When finished measuring, switch off the power. Be sure to remove
the batteries when storing for long periods to avoid leakage
problems.
7. Do not use or store this instrument in a place of direct sunlight,
high temperature and high humidity.
1. Carefully remove the parts and accessories from the box.
2. Make sure that all items listed in the parts lists are included.
3. Inspect the parts carefully to make sure the tool was not damaged
while shipping.
4. Do not discard the packaging material until you have carefully
inspected and satisfactorily operated the tool.

V1.0 Pen-Probe-Style Autoranging Digital Multimeter 9011495
Visit www.princessauto.com for more information 7
WARNING! If any part is missing, do not operate the tool until the
missing parts are replaced. Failure to do so could result in
serious personal injury.
1. Display
2. Button
To enable the
flashlight function,
press and hold down
this button. To turn off
the flashlight, release
the button.
3. Button
To hold the present
reading on the display,
press this button. will appear on the display as an indicator. To
exit the hold mode, press this button again. will no longer appear
on the display. This button can also be used to wake the meter
from sleep mode.
4. Function Switch
Used to select the required function or range, as well as turn off the
meter. To preserve battery life, set this switch to the “OFF” position
when the meter is not is use.
5. Test Probe
Input probe (positive polarity) for the following tests: voltage,
current (< 200mA), resistance, and diode.
6. Flashlight LED
Used for illumination.

9011495 Pen-Probe-Style Autoranging Digital Multimeter V1.0
8 For technical questions call 1-800-665-8685
7. Button
Used to switch the meter between:
• DC voltage and AC voltage measurements
• DC current and AC current measurements
• Diode and continuity tests
8. Button
To turn on or off the backlight, press and hold down this button for
about 1 second. The backlight will turn off automatically about 15
seconds after being turned on.
9. Probe of the Black Test Lead (Negative Polarity)
10. Black Test Lead
1. Set the function switch to the position.
2. Press the button to select DC voltage measurement.
Appears on the display.
3. Connect the test probe and the black test lead across the source
or circuit to be measured.
4. The display shows the reading and the polarity of the test probe
connection.
1. Set the function switch to the position.
2. Press the button to select AC voltage measurement.
Appears on the display.
3. Connect the test probe and the black test lead across the source
or circuit to be measured.
4. The display shows the reading.
1. Set the function switch to the position.
2. Press the button to select DC current measurement.
Appears on the display.

V1.0 Pen-Probe-Style Autoranging Digital Multimeter 9011495
Visit www.princessauto.com for more information 9
3. Connect the test probe and the black test lead in series with the
circuit to be measured.
4. The display shows the reading and the polarity of the test
probe connection.
1. Set the function switch to the position.
2. Press the button to select AC voltage measurement.
Appears on the display.
3. Connect the test probe and the black test lead in series with the
circuit to be measured.
4. The display shows the reading.
1. Make sure the load to be tested is without power and all capacitors
are fully discharged.
2. Set the function switch to the position.
3. Connect the test probe and the black test lead across the load to
be measured.
4. The display shows the reading.
IMPORTANT! If the resistance is more than 1M, it may take
several seconds to stabilize the reading. This is normal for high
resistance measurements.
IMPORTANT! If the probes are open, overload indication will be
shown on the display.
1. Set the function switch to the position.
2. Press the button until appears on the display.
3. Connect the test probe to the anode of the diode and the black test
lead to the cathode of the diode being measured.
4. Read the approximate forward voltage drop of the diode on
the display.

9011495 Pen-Probe-Style Autoranging Digital Multimeter V1.0
10 For technical questions call 1-800-665-8685
1. Turn off the power to the circuit under test, and then discharge all
capacitors and inductors.
2. Set the function switch to the position.
3. Press the button until appears on the display.
4. Connect the test probe and the black test lead across the circuit
being measured.
5. If the resistance of the circuit is less than 50 , the built-in buzzer
will sound.
1. Set the function switch to the position.
2. Connect the black test lead to the ground terminal of the circuit to
be measured and the test probe to the required test point of
the circuit.
3. If the level of the test point is more than or equal to 2.3 ± 0.2V, the
display will show “HI ” and the voltage value. The meter will sound
discontinuously.
4. If the level of the test point is less than or equal to 0.8 ± 0.2V, the
display will show “LO ” and the voltage value. The meter will
sound continuously.
5. If the probes are open, the display will show a TTL logic levels
approximate mid value (1.0 to 1.4V).
CAUTION! Before attempting to open the case of the instrument,
be sure to disconnect the test lead and the test probe from any
energized circuits to avoid shock hazard.
When appears on the display, the battery is low and should be
replaced immediately. To replace the battery, follow these steps:
1. Remove the screws from the battery cover, and then remove the
battery cover.
2. Replace the old battery with new battery of the same type (9V).
3. Reinstall the battery cover and the screws.
Table des matières
Langues :
Autres manuels PROPOINT Multimètre
Manuels Multimètre populaires d'autres marques

Gossen MetraWatt
Gossen MetraWatt METRAmax 6 Manuel utilisateur

PeakTech
PeakTech 4000 Manuel d'utilisation et d'entretien

YOKOGAWA
YOKOGAWA 90050B Manuel utilisateur

Gossen MetraWatt
Gossen MetraWatt METRALINE DMM16 Manuel utilisateur

Fluke
Fluke 8846A Manuel d'utilisation et d'entretien

Tempo Communications
Tempo Communications MM200 Manuel utilisateur