ProMinent DULCODOS Manuel utilisateur

DULCODOS® Pool
DSPa, R01, C01, V01, B01
Assembly and operating instructions
A1114
Original Operating Instructions (2006/42/EC)Part number 985541 BA DD 020 05/12 EN
Please carefully read these operating instructions before use! · Do not discard!
The operator shall be liable for any damage caused by installation or operating errors!
Technical changes reserved.

985541, 1, en_GB
© 2012
ProMinent Dosiertechnik GmbH
Im Schuhmachergewann 5 - 11
69123 Heidelberg
Telephone: +49 6221 842-0
Fax: +49 6221 842-419
email: [email protected]
Internet: www.prominent.com
2

In order to make it easier to read, this document uses the male
form in grammatical structures but with an implied neutral sense. It
is aimed equally at both men and women. We kindly ask female
readers for their understanding in this simplification of the text.
Read the following supplementary information in its entirety!
The following are highlighted separately in the document:
nEnumerated lists
Instructions
ðResults of the instructions
Information
This provides important information relating to the cor‐
rect operation of the system or is intended to make
your work easier.
Safety information
Safety information are provided with detailed descriptions of the
endangering situation, see
Ä Chapter 3.2 ‘Explanation of the
safety information’ on page 10
General non-discriminatory approach
Supplementary information
Supplemental instructions
3

Table of contents
1Identity code.......................................................................... 5
2 About this product................................................................. 7
2.1 Overview of equipment................................................. 7
3 Safety and responsibility....................................................... 9
3.1 Users' qualifications...................................................... 9
3.2 Explanation of the safety information.......................... 10
3.3 General Safety Information......................................... 11
3.4 Correct and proper use............................................... 12
4 Storage and transport......................................................... 14
5Assembly............................................................................ 15
5.1 Wall mounting............................................................. 15
5.2 Fit the antikink device for the bleed line...................... 16
5.3 Hydraulic installation................................................... 17
5.3.1 Metering system...................................................... 18
5.3.2 Sensors.................................................................... 20
5.4 Electrical installation................................................... 21
6 Start up............................................................................... 22
6.1 Priming and bleeding.................................................. 23
6.2 Adjust the flow sensor switching point........................ 23
6.3 Calibration................................................................... 23
7 Maintenance....................................................................... 29
7.1 Maintenance work....................................................... 29
7.2 Troubleshooting.......................................................... 31
7.3 Disposal of used parts................................................ 31
8 Technical data..................................................................... 32
9 Systems.............................................................................. 34
9.1 Spare parts and accessories...................................... 34
9.2 EC Declaration of Conformity..................................... 35
10 Index................................................................................... 37
Table of contents
4

1 Identity code
DSPa DULCODOS® Pool
Measured variable:
R01 Redox (D1C)
C01 Free chlorine (D1C)
V01 Total chlorine (D1C)
B01 Bromine (D1C)
Hardware auxiliary functions:
0 Standard
Software auxiliary functions:
0 none
Communication interfaces:
0 none
Electrical connection:
A 230 V, 50/60 Hz, European standard plug
B 230 V, 50/60 Hz, Swiss plug
Sensor equipment:
0 with sensors
2 Measured variable R01 without sensors
3 Measured variable C01 without sensors
4 Measured variable V01 without sensors
5 Measured variable B01 without sensors
Version:
0 with logo
1 without logo
Language**:
A Swedish H Swiss
D German I Italian
E English N Dutch
F French P Polish
G Czech S Spanish
Metering pumps for acid / alkali:
0 without metering pumps
Multifunctional valve for acid/alkali pump:
0 none
1with MFV (only for Beta®)
Metering pumps for disinfection:
0 without metering pumps
Identity code
5

DSPa DULCODOS® Pool
10.8 l/h DULCO®flex for up to 45/10
m3/h circulation HB/FB*
21.6 l/h DULCO®flex for up to
100/20 m3/h circulation HB/FB*
32.4 l/h DULCO®flex for up to
140/30 m3/h circulation HB/FB*
41.8 l/h alpha for up to 100/20 m3/h
circulation HB/FB*
53.5 l/h alpha for up to 200/40 m3/h
circulation HB/FB*
60.9 l/h Beta®flex for up to 50/10
m3/h circulation HB/FB*
72.1 l/h Beta®flex for up to 125/25
m3/h circulation HB/FB*
83.9 l/h Beta®flex for up to 225/45
m3/h circulation HB/FB*
Multifunctional valve for disinfec‐
tion pump
0 none
1with MFV (only for Beta® and
alpha)
Assembly
0 supplied loose without
assembly plate
1 assembled on a base plate
Certification
0 with CE mark
* Calculated for 12 % sodium-calcium hypochlorite:
nHB = Indoor swimming pool
nFB = Outdoor swimming pool
** Other languages upon request
Identity code
6

2 About this product
DULCODOS® Pool metering systems are specifically designed for
the treatment of swimming pool water. Ready mounted, fully-wired
and ready for use, they provide disinfection using chlorine or bro‐
mine.
DULCODOS® Pool metering systems are equipped with all neces‐
sary components mounted on a plate.
nSensors
nController
nMetering pumps
2.1 Overview of equipment
A1115
13.
12.
11.
10.
9.
8.
7.
6.
5.
4.
3.
2.
1.
Fig. 1: Overview of equipment based on the example DULCODOS® Pool metering system R01 (with all
options and metering pump Beta® or DF2a)
1. Redox controller
2. Flow sensor
3. Redox sensor*
4. Flow module with flow sensor
5. Ball valve, inlet side
6. Disinfectant injection valve
7. Sampling tap
8. Metering pump Beta® disinfectant
9 Cable disinfectant level switch (only
with metering pump )
10. Suction assembly disinfectant
11. Metering pump DF2a disinfectant
12. Dirt filter
13. Ball valve, outlet side
Not shown
in figure
Disinfectant multifunctional valve
* To be fitted by the customer. These
components are ready for subsequent
installation, but are supplied sepa‐
rately to avoid damage in transit.
Components P01
About this product
7

2.
1.
4.
A1116
3.
Fig. 2: Control elements for the example DULCODOS® Pool
metering system R01 (with all options and metering pumps Beta®)
The following are used as control elements:
1. Controller keys and display
2. Flow meter (by scale)
3 Stroke adjustment dial of the metering pump (con‐
cealed with the alpha pump)
4. Ball valve, in-line probe housing, inlet side
(Not shown in
figure)
Multifunctional valve
Control elements e.g. R01
About this product
8

3 Safety and responsibility
3.1 Users' qualifications
WARNING!
Danger of injury with inadequately qualified personnel!
The operator of the plant / device is responsible for
ensuring that the qualifications are fulfilled.
If inadequately qualified personnel work on the unit or
loiter in the hazard zone of the unit, this could result in
dangers that could cause serious injuries and material
damage.
– All work on the unit should therefore only be con‐
ducted by qualified personnel.
–Unqualified personnel should be kept away from
the hazard zone
Training Definition
Instructed personnel An instructed person is deemed to be a person who has been instructed and,
if required, trained in the tasks assigned to him/her and possible dangers that
could result from improper behaviour, as well as having been instructed in the
required protective equipment and protective measures.
Trained user A trained user is a person who fulfils the requirements made of an instructed
person and who has also received additional training specific to the system
from ProMinent or another authorised distribution partner.
Trained qualified per‐
sonnel
A qualified employee is deemed to be a person who is able to assess the
tasks assigned to him and recognize possible hazards based on his/her
training, knowledge and experience, as well as knowledge of pertinent regula‐
tions. The assessment of a person's technical training can also be based on
several years of work in the relevant field.
Electrician Electricians are deemed to be people, who are able to complete work on elec‐
trical systems and recognize and avoid possible hazards independently based
on his/her technical training and experience, as well as knowledge of pertinent
standards and regulations.
Electricians should be specifically trained for the working environment in
which the are employed and know the relevant standards and regulations.
Electricians must comply with the provisions of the applicable statutory direc‐
tives on accident prevention.
Customer Service depart‐
ment
Customer Service department refers to service technicians, who have
received proven training and have been authorised by ProMinent to work on
the system.
Note for the system operator
The pertinent accident prevention regulations, as well
as all other generally acknowledged safety regulations,
must be adhered to!
Safety and responsibility
9

3.2 Explanation of the safety information
These operating instructions provide information on the technical
data and functions of the product. These operating instructions pro‐
vide detailed safety information and are provided as clear step-by-
step instructions.
The safety information and notes are categorised according to the
following scheme. A number of different symbols are used to
denote different situations. The symbols shown here serve only as
examples.
DANGER!
Nature and source of the danger
Consequence: Fatal or very serious injuries.
Measure to be taken to avoid this danger
Danger!
–Denotes an immediate threatening danger. If this is
disregarded, it will result in fatal or very serious
injuries.
WARNING!
Nature and source of the danger
Possible consequence: Fatal or very serious injuries.
Measure to be taken to avoid this danger
Warning!
–Denotes a possibly hazardous situation. If this is
disregarded, it could result in fatal or very serious
injuries.
CAUTION!
Nature and source of the danger
Possible consequence: Slight or minor injuries, mate‐
rial damage.
Measure to be taken to avoid this danger
Caution!
–Denotes a possibly hazardous situation. If this is
disregarded, it could result in slight or minor inju‐
ries. May also be used as a warning about material
damage.
NOTICE!
Nature and source of the danger
Damage to the product or its surroundings
Measure to be taken to avoid this danger
Note!
–Denotes a possibly damaging situation. If this is
disregarded, the product or an object in its vicinity
could be damaged.
Introduction
Safety and responsibility
10
Table des matières
Autres manuels ProMinent Filtre de piscine
Manuels Filtre de piscine populaires d'autres marques

JUWEL Aquarium
JUWEL Aquarium EccoSkim Manuel utilisateur

POLYGROUP LIMITED
POLYGROUP LIMITED SFS600 Filter System with F600C Pump Manuel utilisateur

Pentair Pool Products
Pentair Pool Products Filter CFW Series Manuel utilisateur

Oase
Oase Skimmer 250 Manuel utilisateur

Oase
Oase CrystalSkim 350 Manuel utilisateur

AquaScape
AquaScape 43021 Instructions d'utilisation