CONVERTS 12 VOLT DC – 230 VOLT AC
POWERS HOUSEHOLD APPLIANCES
FROM A 12 VOLT BATTERY
POWER INVERTER
P/No.s IMW300, IMW600, IMW1000, IMW2000

WARNING
•
For use with negatively earthed vehicles & systems only.
•
For indoor use out of weather only.
•
Internally bonded for safety, battery DC negative to case & AC socket earth .
•
Hazardous voltage inside - do not attempt to open or repair.
•
Do not use if damaged.
•
Read operating manual before using or making any connections.
•
Only connect 230V AC appliances that are in safe condition.
•
It is recommended that a type ‘A’ portable residual current device (RCD)
be used for added output protection.
•
For independent use, do not connect to buildings.
FEATURES
•
Peak Power Technology runs appliances with high start up loads.
•
•
Built in safety protection against AC power overload and low battery.
•
Heavy Duty power leads for direct battery connection.
•
Approved AS/NZS power outlet sockets.
•
Twin power outlet sockets (except IMW300).
• 5V DC 2.1A USB power socket.
• Axial cooling fan.
• Temperature controlled automatic cooling fan (except IMW300).
2

P/No. IMW300 IMW600 IMW1000 IMW2000
SPECIFICATIONS:
Input 12V Battery/Vehicle (11–15V DC)
Input Current: (Max DC Amps) 32A 63A 104A 208A
Input Standby Current (+/-5%) 400mA 400mA 600mA 600mA
Output 230 Volt AC, 50Hz (Modified Sine Wave)
Continuous Output Power (Watt) 300W 600W 1000W 2000W
Peak Output Power (Watts) 600W 1200W 2000W 4000W
USB Output 5V DC 2.1A Max.
Efficiency 85%
Low Battery Alarm/Shutdown Alarm 10.2–10.8 Volt/Shutdown 9.2–9.8 Volt
Cooling Fan By Load Automatic temperature controlled
Thermal Shutdown 65˚ (+/-5˚ C)
Replacement Fuse Standard Auto Blade Fuse
Fuse Quantity & Size 1 x 40A 2 x 40A 3 x 40A 7 x 35A
Fuse Location External Internal* Internal* Internal*
Connection Cable 3mm2/900mm 6mm2/900mm 16mm2/1100mm 25mm2/1100mm
Dimensions (cm) 20.1 x 10.2 x 6.3 22.6 x 16.2 x 7.3 26.1 x 16.2 x 7.3 37.2 x 21.7 x 10.0
Weight 0.8kg 1.41kg 2.0kg 4.18kg
Approvals Electrical safety (AS/NZS4763:2011), EMC
3

WHAT IS AN INVERTER?
Inverters are designed for powering household appliances from a battery or vehicle. They are
electronic devices that convert (12V DC) battery power to (230V AC) mains power.
Inverters are compact and often lightweight making them an ideal source of portable mains power.
Thanks to their portability they are commonly used in cars, caravans, motor homes, boats, 4WD’s
and utility vehicles.
Using an inverter with standard household appliances is a much cheaper option than purchasing
specialised 12V appliances for times when power is not available.
These are two different types of inverters, modified sine wave and pure sine wave. The difference
between the two is how close the output replicates mains power.
ed sine wave and pure
sine wave inverters.
Logically it follows that the process used in a pure sine wave inverter is more complex than a
modified sine wave inverter and subsequently they are lot more expensive.
ed sine wave and hence they are
more common.
Pure sine wave inverters are reserved for use on medical equipment and sensitive electrical
appliances.
Inverters are available with different power output levels to suit the type of appliances to be
powered. Small inverters are designed for powering one small low power electrical or electronic
appliance. Larger inverters can be used to power multiple small appliances or one larger appliance.
cient method for running appliances with very high power
requirements such as electric heaters, stoves, kettles and air conditioners. This is due to their
high current draw and battery consumption.
0
100
200
300
400
-400
-300
-200
-100
0
100
200
300
400
-400
-300
-200
-100
0
100
200
300
400
-400
-300
-200
-100
MAINS POWER (SINE WAVE) MODIFIED SINE WAVE PURE SINE WAVE
4

5
CONNECTIONS / CONTROLS & ACCESSORIES
After unpacking your inverter take a moment to check that you have all the correct accessories for
your model and familiarise yourself with the connections and controls.
P/No. IMW300
FRONT
AC OUTPUT
SOCKET FUSE FANDC TERMINALS
REAR
CHASSIS GND
P/No. IMW1000 & IMW2000
Supplied:
• Operating instructions
• tted with ring terminal (1100mm)
• tted with ring terminal (1100mm)
FRONT
AC OUTPUT
SOCKETS
POWER ON
IMW1000 shown
IMW2000 is slightly different SWITCH
DC TERMINALSPOWER & FAULT
LIGHTS
REAR
CHASSIS GND
P/No. IMW600
Supplied:
• Operating instructions
• tted with battery clips (900mm)
• tted with battery clips (900mm)
FAN FAN
POWER ON
SWITCH
POWER & FAULT
LIGHTS
FRONT
AC OUTPUT
SOCKETS
POWER ON
USB
SOCKET
USB
SOCKET
USB
SOCKETSWITCH
FANDC TERMINALSPOWER & FAULT
LIGHTS
REAR
CHASSIS GND
FAN

6
PLACEMENT / LOCATION / MOUNTING OF INVERTER
Caution:
•
•
Batteries should be mounted in a separate well-vented enclosure.
•
For vehicle or camping use the inverter must be protected from rain, water or moisture.
Projecta inverters are designed for indoor, out of weather use only. For best performance the
inverter must be used or mounted in a cool, dry, clean and well-ventilated area.
For best TV / Radio reception keep inverter as far away from TV’s, radios, antenna cables and
antennas as possible.
All models are supplied with mounting brackets. If used in mobile applications such as 4WD,
Caravan, Motor home or boat the inverter should be mounted to a suitable horizontal or vertical
panel, with at least 50cm clearance from the rear panel of the inverter to provide good ventilation
for the cooling fan.
SUITABLE
POWER SOURCE:
In order to operate the inverter and supply power to an appliance a suitable 12V DC power supply is
required. This can be a vehicle or caravan battery, portable power pack or an independent 12V lead
acid battery. For most applications, a deep cycle battery is recommended for best performance.
The size of the battery used will determine how long the inverter will supply power to an appliance
and how well the inverter will perform. Most batteries are marked with their size in Amp hours (Ah)
or Cold Cranking Amps (CCA).
Because 12 Volt inverters are capable of drawing high currents the inverter should only be
connected to a suitable size battery. Connection to an undersized battery could damage the battery
and will result in the inverter shutting down within a short period due to low battery voltage.
The amount of power drawn from the battery is proportional to the inverter load.
P/No. IMW300 IMW600 IMW1000 IMW2000
Minimum Recommended
Battery Size
24Ah
(200CCA)
50Ah
(400CCA)
75Ah
(550CCA)
85Ah
(600CCA)
Run time with maximum
load & minium battery size
40min 30min 15min 5min
Run time for a 100 Watt globe
with minimum battery size
2 hours 4 hours 6 hours 7 hours
Ideal battery size 50-70Ah 50-130Ah 75-250Ah 84-400Ah

CONNECTION TO POWER SOURCE & EARTHING
Caution:
•
Even though the inverter is powered from a battery, it still produces Dangerous High Voltage
AC power and has the potential to fatally injure if incorrectly installed or used.
•
Before making any connections ensure inverter is switched off and has no AC appliances
plugged into the AC output sockets.
•
Ensure vehicle / system is a negative earthed or negative ground system only.
•
Double check battery negative and positive posts before making any connection, a wrong
connection (Reverse polarity) will cause the fuse/s to blow and may damage the inverter.
•
when the inverter has not been used for some time. This spark is caused by the inverter’s large
capacitors charging quickly. To minimise this, make the last connection quickly and completely.
•
•
Batteries can be dangerous, follow all battery manufacturer’s instructions and warnings.
•
Projecta inverters are designed FOR INDEPENDENT USE ONLY. That is, they cannot be
connected to household wiring whether the building is connected to the electricity grid or not.
•
Never operate the inverter without the DC negative input connected direct to the battery and
never install a fuse, circuit breaker or battery switch in the negative supply line.
P/No. IMW300, IMW600, IMW1000 & IMW2000
These inverters can be connected to a power source on a temporary basis with the supplied
DC leads (see the section Temporary Connection) or hard wired for a permanent installation
with suitably sized cable and hardware for your application (see the section Hard Wired
Connection). Regardless of which connection method is used it may be advantageous to earth
the inverter case, see the section on External Earthing for more details.
7

8
TEMPORARY CONNECTION:
•
Connect the ring terminal on the negative lead (Black) to the negative (Black) DC terminal on
the back of the inverter.
•
Connect the battery clip (Black) or ring terminal (IMW1000, IMW2000) on the other end of the lead
to the negative DC supply or (-) battery terminal.
•
Connect the ring terminal on the positive lead (Red) to the positive (Red) DC terminal on the
back of the inverter.
•
Connect the battery clip (Red) or ring terminal (IMW1000, IMW2000) on the other end of the lead
to the positive DC supply or (+) battery terminal.
CHASSIS GND
INPUT POS.
INPUT NEG.
+
–

“HARD WIRED” CONNECTION
When mounting the inverter in a vehicle, caravan, boat or cabin it may be preferable to use
longer DC battery cables than those supplied, so that the inverter can be placed in a more
convenient, cooler or more protected location.
If longer cables are required only use suitably insulated automotive battery cable according to the
following table (Note: B&S = AWG)
P/No. IMW300 IMW600 IMW1000 IMW2000
Up to 2m 8 B&S
(8mm2)
6 B&S
(14mm2)
3 B&S
(26mm2)
2 B&S
(35mm2)
3m 8 B&S
(8mm2)
3 B&S
(26mm2)
2 B&S
(32mm2)
0 B&S
(49mm2)
4m 6 B&S
(14mm2)
2 B&S
(32mm2)
0 B&S
(49mm2)
00 B&S
(64mm2)
6m 3 B&S
(26mm2)
0 B&S
(49mm2)
00 B&S
(64mm2)
Not
Recommended
• It is recommended that a circuit breaker or high current fuse be placed in the DC positive (+) line
close to the battery.
P/No. IMW300 IMW600 IMW1000 IMW2000
Fuse or Circuit
Breakers size (+) Only
40AMP 100AMP 150AMP 250AMP
(or 2 x 150AMP
in parallel)
• It is recommended that a heavy duty battery switch with a current rating higher than the fuse
tted in the DC positive (+) line close to the battery to allow the supply to the
inverter to be switched off, this can also be achieved by using a circuit breaker which has
a trip facility.
• Positive and Negative cables should be run close together to reduce cable inductance, and be
protected from damage by corrugated conduit.
CORRUGATED CONDUIT
IMW300 shown
SWITCH
FUSE
9

EXTERNAL EARTHING: (OPTIONAL)
Projecta inverters have been internally bonded for safety, by connecting the AC socket/s earth pin to
the inverter case and to the DC negative supply input. Because of this most installations do not
require the inverter to be earthed. However if the inverter is used in a stationary land based
application or if the inverter is causing interference with TV sets or radios it is recommended that an
external earth connection is made by one of the following methods:
.
•
External Earthing Stationary Applications – Connect an earth wire (Preferably solid Green
or Green with Yellow stripe) from the external earth connection (Chassis GND) on the rear of the
inverter to a metal stake or pipe that is driven into the ground at least 1.2m.
•
External Earthing Mobile Applications – Connect an earth wire (Preferably solid Green or Green
with Yellow stripe) from the external earth connection (Chassis GND) on the rear of the inverter to
the chassis of the vehicle or ground wires in a boat.
EARTH STAKE 1.2M
IMW300 shown
IMW300 shown
CHASSIS CONNECTION
10
Ce manuel convient aux modèles suivants
3
Autres manuels Projecta Onduleur

Projecta
Projecta SC300D Manuel utilisateur

Projecta
Projecta PW150 Manuel utilisateur

Projecta
Projecta IP150 Manuel utilisateur

Projecta
Projecta IP2000 Manuel utilisateur

Projecta
Projecta IM300 Manuel utilisateur

Projecta
Projecta SC110 Manuel utilisateur

Projecta
Projecta IP3000 Manuel utilisateur

Projecta
Projecta PW500 Manuel utilisateur