Princess 352103 Manuel utilisateur

EN Instruction manual
Air conditioner
01.352103.02.001

PARTS DESCRIPTION

Instruction manual
3
SAFETY
• Please read this user’s manual carefully to
ensure proper use, maintenance and
installation.
• By ignoring the safety instructions the
manufacturer cannot be held responsible for
the damage.
• The appliance is for indoor use only.
• Do not use the unit on a socket that is
damaged or that has not been installed
correctly.
• Do not use the unit:
– near a source of fire.
– in an area where oil is likely to splash.
– in an area exposed to direct sunlight.
– in an area where water is likely to
splash.
– near a bath, a shower or a swimming
pool.
• Never insert your fingers or objects into the
air outlet. Take special care to warn children
of these dangers.
• Keep the unit upright during transport and
storage.
• Before cleaning the unit, always turn off or
disconnect the power supply.
• Always turn off and disconnect the power
supply before moving the unit.
• WARNING: To avoid the risk of fire, do
not cover the unit.
• All the unit sockets must comply with the
local electric safety requirements. If
necessary please check.
• If the supply cord is damaged, it must be
replaced by the manufacturer, its service
agent or similarly qualified persons in order
to avoid a hazard.
• If the supply cord is damaged, it must be
replaced by the manufacturer, service agent
or qualified person(s) in order to avoid a
hazard.
• This appliance can be used by children aged
8 years and above, persons with reduced
physical, sensory, and mental capabilities or
persons with a lack of experience and
knowledge if they have been given correct
supervision or instruction concerning the use
of the appliance in a safe way and
understand the hazards involved. Children
should not play with the appliance. Cleaning
and user maintenance should not be carried
out by children without supervision.
EN

Instruction manual
4
• This appliance is only to be used for household
purposes and only for the purpose it is made
for.
• Notes:
– In the case of any damage, please
disconnect the power supply and contact
the dealer or a designated repair shop.
– In any case, the power cord shall be firmly
grounded.
– To avoid the possibility of danger, if the
power cord is damaged, please disconnect
the power supply. It must be replaced by the
dealer or a designated repair shop.
Warning
• Please use the recommended defrosting and
cleaning process from the manufacturer only.
Do not accelerate the defrosting or cleaning
process in any other way.
• The appliance shall be stored in a room without
continuously operating ignition sources (for
example: open flames , an operating gas
appliance or an operating electric heater).
• Do not pierce or burn.
• Be aware that refrigerants may not contain an
odor.
• The appliance should be installed, operated and
stored in a room with a floor area larger than X
m2. (X=4 for 5000Btu/h, 7000Btu/h, 8000Btu/h;
X=7.7 for 9000Btu/h. 10000Btu/h, 10500Btu/h)
• Only contact an authorized service technician
for repair or maintenance of this unit.
• Do not pull , deform or modify the power supply
cord or immerse in water . Pulling or misuse of
the power supply cord could result in damage to
the unit and cause an electrical shock.
• Compliance with national gas regulations
should be observed.
• Keep ventilation openings clear of obstructions.
• Any person who is involved with working on or
opening a refrigerant circuit should hold a
current valid certificate from an industry
accredited assessment authority which
authorizes their competence to handle
refrigerants safely in accordance with an
industry recognized assessment specification.
• Servicing should only be performed as
recommended by the equipment manufacturer.
Maintenance and repair requiring the assistance
of other skilled personnel should be carried out
under the supervision of a person(s) competent
in the use of flammable refrigerants.

Instruction manual
5
• Do not stop the unit by pulling out the power
plug whilst in operation as this may cause
an electric shock or fire due to heat
generation unless strange sounds are heard
or if strange smells or smoke appear from
the unit.
Specific information regarding appliances with R 290 refrigerant gas.
• Thoroughly read all of the warnings.
• When defrosting and cleaning the
appliance , do not use any tools other than
those recommended by the manufacturing
company.
• The appliance should not be stored in a
room with continuously operating ignition
sources (for example: open flames , an
operating gas appliance or an operating
electric heater).
• Do not puncture and do not burn.
• Appliance shall be installed, operated and
stored in a room with a floor area larger than
X m2. (X=4 for 5000Btu/h, 7000Btu/h,
8000Btu/h; X=7.7 for 9000Btu/h. 10000Btu/
h, 10500Btu/h)
• This appliance contains Y g (see rating label
back of unit ) of R290 refrigerant gas.
• R290 is a refrigerant gas that complies with
the European directives on the environment.
Do not puncture any part of the refrigerant
circuit.
• If the appliance is installed, operated or
stored in a non-ventilated area, the room
must be designed to prevent to the
accumulation of refrigerant leaks that could
result in a fire risk or explosion due to
ignition of the refrigerant caused by electric
heaters, stoves, or other sources of ignition.
• The appliance must be stored in such a way
as to prevent mechanical failure.
• Individuals who operate or work on the
refrigerant circuit must have the appropriate
certification issued by an accredited
organization that ensures competence in
handling refrigerants according to a specific
evaluation recognized by associations in the
industry.
• Repairs must be performed based on the
recommendation from the manufacturing
company. Maintenance and repairs that
require the assistance of other qualified
personnel must be performed under the
EN

Instruction manual
6
supervision of an individual specified in the use
of flammable refrigerants.
Batteries
• Do not expose the battery to high temperatures
or direct sunlight. Never throw batteries into the
fire. There is a danger of explosion!
• Keep batteries away from children. Batteries are
not a toy!
• Do not open the batteries by force.
• Avoid contact with metallic objects.(Rings, nails,
screws et cetera) there is a danger of short-
circuiting!
• As a result of a short-circuit batteries may heat
up consider-ably or even catch fire. this may
result in burns.
• For your safety the battery poles should be
covered with adhesive strips during transport.
• Do not touch a ruptured and/or leaking battery.
If the liquid from the battery gets into your eyes,
rinse your eyes as soon as possible with clean
water, without rubbing your eyes. Immediately
go to the hospital. If it is not treated properly, it
can cause eye problems.
Refrigerant
(CE) N 842/2006: This unit contains the refrigerant R290. The amount of
refrigerant is less than 1kg, and is in a closed cooling circuit. The coolant
does have zero ozone depletion potential, but is a so-called greenhouse
gases under the Kyoto Protocol and may thus contribute to global
warming, if it is released to the atmosphere. Therefore only trained
technicians with refrigerant certificate make a filling or emptying. Your
appliance does not have be refilled with refrigerant if used properly and
has an undamaged coolant circuit. GWP: R290: 3
PARTS DESCRIPTION
1. Air inlet 8. Hose connector (window end)
2. Air filter 9. Hot-air exhaust hose
3. Control panel 10. Hose connector (Air conditioner end)
4. Power cord 11. Windows slider kit + fixing plugs
5. Air outlet 12. Remote control
6. Castor 13. Batteries
7. Drainage hole

Instruction manual
7
FUNCTION OF CONTROL PANEL
1. Power (on/off) button
2. Temperature buttons
3. Mode button
4. Fan speed adjustment button
5. Timer (on/off) button
EN

Instruction manual
8
REMOTE CONTROL
1. Temperature up button
2. Mode button
3. Fan speed adjustment button
4. Timer (on/off) button
5. Temperature down button
6. Power (on/off) button
BEFORE THE FIRST USE
Before starting operations in this section:
• Find a place where there is power supply nearby.
• Install the exhaust hose and adjust the window position well.
• The supplied small white clips must be mounted on the window kit.
• Insert the power cord into a grounded AC220~240V/50Hz socket.
• Press the power button to turn on the air-conditioner.
• Set the temperature range: 16°C-31°C.
• Check whether the exhaust hose has been mounted properly.
• When using functions on cooling and dehumidifying, allow at least 3
minutes between powering off and powering on.
USE
Cooling operation

Instruction manual
9
• Press the “Mode“ button till the “Cool“ icon appears.
• Press the or button to select a desired room
temperature.
• Allow around 5 minutes for the cooling to start.
• Press the “fan speed” button to adjust airflow.
Dehumidifying operation
• Press the “Mode“ button until the “dehumidify indicator lamp“
blinks.
• The temperature will automatically be selected.
• The fan speed will automatically be selected.
Timer operation
Timer ON setting
• When the air-conditioner is OFF, press the “Timer“ button and
select a desired ON time and adjust using the temperature
buttons.
• The ON time can be adjusted to anytime in 0-24 hours.
Timer OFF setting
• When the air-conditioner ON, press “Timer“ button and select a
desired OFF time through the temperature buttons.
• The OFF time can be adjusted to anytime in 0-24 hours.
Drainage
• After a lengthy operation and before storage, you will need to
drain the water that has been collected. Please prepare a
suitable location or tray to collect the water and remove the
rubber stop from the drainage hole at the bottom of the unit. The
water will then begin to drain. After this has stopped, you can
insert the drain stop.
Internal Tank Water Full Alarm Function
• The inner water tank in the air-conditioner has one water level
safety switch that controls the water level. When the water level
reaches an anticipated height, the water full indicator lamp lights
up. Follow above steps to drain the water.
INSTALLATION
• The air-conditioner should be installed on a flat and stable
surface. Do not block the air outlet and allow at least 30cm
around the unit.
• Socket wiring should be in accordance with the local electric
safety requirements.
EN

Instruction manual
10
Exhaust Hose Installation
• Twist both ends of the hot-air exhaust hose(9) into the hose connector
window end(8) and the hose connector air conditioner end(10).
• Insert the hose connector air conditioned end(10) into the openings at
the back of the air conditioner.
• Fix the hose connector window end(8) to the nearest windowsill.
Window Slider Kit Installation
• Adjust the width (picture 1) or height (picture 2) of the windows
slider(11) to fit the window opening and fixate the position of the
windows slider(11) with the fixing plugs.
• Slide the window up to the slider.
Ce manuel convient aux modèles suivants
1
Table des matières
Autres manuels Princess Climatiseur

Princess
Princess Smart 01.358640.02.001 Manuel utilisateur

Princess
Princess Smart Air Conditioner 9000 Manuel utilisateur

Princess
Princess Smart Air Conditioner 9000 Manuel utilisateur

Princess
Princess 352712 Manuel utilisateur

Princess
Princess Smart Air Conditioner 12000 Manuel utilisateur

Princess
Princess 01.352718.01.001 Manuel utilisateur