SESTO SENSO 2 robotic focusing motor-
USER MANUAL

PrimaLuceLab iSrl SESTO SENSO 2 user manual
English
WARNING
If improperly handled, SESTO SENSO 2 may damage. So please follow the instructions below:
•Do not disassemble
•Do not open, damage or subject to electric shock or excessive impact any part of SESTO SENSO 2. Do not drop.
•Do not short the electronic elements
•Do not expose at temperatures below -20°C and above +60°C
•Do not burn or incinerate any component.
•Do not expose to rain or other atmospheric effect related to water
•Do not bend, modify or force any part of SESTO SENSO 2
Index
Components Identification 2
Contents of the package 2
Technical specifications 3
Installing SESTO SENSO 2 on the telescope’s focuser 4
Controlling SESTO SENSO 2 with EAGLE or computer with Windows OS 6
Controlling SESTO SENSO 2 with Virtual HandPad 12
SESTO SENSO 2 Advanced Settings 15
Controlling SESTO SENSO 2 with ASCOM drivers and third party softwares 17
INFORMATION TO USERS 21
page 1
QUALITY CONTROL
Each SESTO SENSO 2 unit, after created in our laboratories, it’s tested by PrimaLuceLab technical experts to check all components.
We verify mechanics and electronics. In case you check any malfunction, please contact us immediately (+ 39-0434-1696106 or
[email protected]). Do not try to disassemble, repair or modify yourself SESTO SENSO 2, without our written approval, in
order not to loose the Producer Warrantee.

PrimaLuceLab iSrl SESTO SENSO 2 user manual
Components Identification
Contents of the package
•SESTO SENSO 2 robotic focusing motor
•5 bushings
•Allen keys with grub screws
•Power cable for cigarette plug
•USB-C to USB cable
•Quick Start guide
page 2

PrimaLuceLab iSrl SESTO SENSO 2 user manual
Technical specifications
page 3
CAUTION
In order to correctly use SESTO SENSO 2, you have to connect it to your telescope’s focuser. The installation procedure
changes based on the telescope’s focuser so please refer to the next paragraphs. But if you want, you can proceed with
the SESTO SENSO 2 first use also without having the focuser not installed on the telescope’s focuser.
NOTE
In order to proceed with installation you have to download the SESTO SENSO 2 drivers and softwares package from our
website:
www.primalucelab.com/astronomy/downloads
Save the package (it’s in zip format) in the EAGLE or computer you want to use to control the SESTO SENSO 2 and unzip
it with the proper unzip software (if you haven’t an unzip software, you can use https://www.winzip.com).
Power
12V
Power consumption @ 12V
800mA max
Working temperature
-20°C / +60°C
Control with:
USB
WiFi
Resolution
0,7 microns per step
Temperature probe
Internal to read motor temperature (in the package)
External for focus temperature compensation (optional)
Provided software
Driver for Windows 64 bits (compatible with Windows Vista, 7, 8 and 10)
FOCUSER Manager for control with Windows operative system
ASCOM driver for control from external software (tested with ASCOM platform 6.4)
SESTO SENSO 2 Virtual HandPad for WiFi control
Weight
380 grams

PrimaLuceLab iSrl SESTO SENSO 2 user manual
Installing SESTO SENSO 2 on the telescope’s focuser
In order to connect SESTO SENSO2 to the focuser of your telescope, remove the manual focus micrometric knob by un-
screwing the screw normally present on the knurled knob. After pulling it out, you also need to disconnect the coarse fo-
cuser knob, by means of an allen screw on the knob. On some plastic-covered focusers, you need to remove the plastic to
access the disassembly screw. Connect one of the bushings you find in the SESTO SENSO 2 box (based on the diameter
that fits your focuser) to the small focuser shaft of your focuser.
Now you can connect SESTO SENSO 2 to your focuser by paying attention to centering the micrometric pin with the pre-
assembled bushing on SESTO SENSO 2, until it stops. By using the provided allen screw, lock the 2 grub screws that fix
the pre-assembled bushing on SESTO SENSO 2 to the bushing you just installed on your focuser's shaft.
page 4
NOTE
in order to work, SESTO
SENSO 2 requires your
focuser to have the micro
metric knob.

PrimaLuceLab iSrl SESTO SENSO 2 user manual
Then, by using the provided allen screw, please fix the screws that fix the outer ring of SESTO SENSO 2 to your focuser.
Finally, use the allen screw to lock the 3 small grub screws fix the outer ring of SESTO SENSO 2 to your focuser.
page 5
NOTE: After installing SESTO SENSO 2 on your focuser, check the smoothness of the movement keeping SESTO SENSO
2 powered off and then manually moving the focus knob of your focuser. The presence of SESTO SENSO 2 will make the
movement harder (since the motor is connected) but the motion must still be uniform. If you notice an uneven move-
ment, repeat the installation procedure.
NOTE: SESTO SENSO 2 connects to several focusers that may have different machining and tolerances precisions. Fo-
cusing accuracy, especially when using automatic focusing procedures, depends on the focuser mechanics and not only
strictly on SESTO SENSO 2. If your focuser has an important backlash, you can adjust the backlash parameter in the
software.

PrimaLuceLab iSrl SESTO SENSO 2 user manual
Controlling SESTO SENSO 2 with EAGLE or computer with Windows OS
SESTO SENSO 2 can be controlled with the EAGLE or any external computer that comes with Windows operative system
(at least version 7 64 bits). In the SESTO SENSO 2 package you can find a 12V power cable with cigarette plug and a PC
connection cable for USB port. Connect the USB-C cable to the USB port of your EAGLE or personal computer. You will see
the PWR LED on (this means SESTO SENSO 2 is powe-
red) and, after a few seconds the Wi-Fi LED will be on
too and this means that also the SESTO SENSO 2 WiFi
connection is ready to be used.
When you connect it to USB port of the EAGLE or of an
external computer, SESTO SENSO 2 should be automa-
tically detected and Windows should automatically
install the new driver. In order to check this, please go
to Control Panel and then choose Device Manager. You
should see the SESTO SENSO 2 listed under “Ports
(COM & LPT)” and described as “Silicon Labs
CP210x” (in order to check, you can disconnect and
then reconnect the SESTO SENSO 2 USB cable and see
how Windows lists it).
If you can’t find it, Windows is not able to automatically install the SESTO SENSO 2 driver. In order to do this, please follow
this procedure:
1) go to "Device Manager”
2) locate "CP2102N USB to UART Bridge Controller" under "Other devices”
3) make a mouse right-click and select "Update Driver Software”
4) select the second option “Browse my computer for driver software” in order to install the driver from a specific folder
5) select the folder where you saved the content of the SESTO SENSO 2 software package you downloaded from our
website
www.primalucelab.com/astronomy/downloads
Please remember to unzip the file you downloaded before starting the installation of the SESTO SENSO 2.
6) at the end of the procedure, a message will appear indicating the correct installation.
Now, under “COM and LPT devices”, you will see a new COM port (in this example COM16) which is the one used by your
computer to communicate with SESTO SENSO 2.
page 6
NOTE
If the driver is not correctly installed in your Windows operative system, SESTO SENSO 2 won’t be able to connect to
your EAGLE or external computer and it won’t work. So please check that the COM driver is correctly installed before
proceeding to the next step.

PrimaLuceLab iSrl SESTO SENSO 2 user manual
SESTO SENSO 2 is supplied with a complete Windows software
“FOCUSER Manager” (included in the file that you download
from the download section of our website) that allows you to
control the SESTO SENSO 2 and manage all its functions. Make
a double click on FOCUSERManagerSetup.exe file to start in-
stallation. Click OK to proceed. In the first window that opens,
please select your language and click the “OK” button to start
the installation.
Then, in the next window, click the “Next” button.
Select the folder where you want to install FOCUSER Manager
software (if you want to change the default one, you can click
on the Browse button and choose for a different folder). Then
click on the “Install” button to start installation.
At the end of installation process, please click on “Close” button to finish. Now you will find the FOCUSER Manager soft-
ware among the softwares installed in your EAGLE or Windows computer. If you leaved the default folder, it will be loca-
ted in “C:\Program Files (x86)\FOCUSER manager” folder.
page 7

PrimaLuceLab iSrl SESTO SENSO 2 user manual
Having connected SESTO SENSO 2 to a USB port of your EAGLE or Windows computer and powered with an external po-
wer source (a 12V battery by using the supplied cigarette plug cable, a 12V AC adapter with at least 1A and Ø5.5/2.5mm
connector or the EAGLE power cable to power it through the EAGLE), pleas select “FOCUSER Manager” software to start it
and you will see this interface:
On the left, select the COM port number your compu-
ter assigned to the SESTO SENSO 2 and click on the
“Open/Close” button. You will see the lights on the
right become green. If you connected also the optional
temperature sensor, you will get the green light also in
correspondence to the “External temperature” row.
page 8
What happens if I can’t connect by pressing the “Open/Close” button?
At this stage, if you can’t connect to SESTO SENSO 2 by pressing the “Open/Close” button, please check the COM port
number that your EAGLE or personal computer assigned to the SESTO SENSO 2. In order to do that, please go to Control
Panel -> Device Manager and search for the SESTO SENSO 2 COM port number. This is the number you have to select in
the FOCUSER Manager software, before starting the connection.
NOTE on internal temperature values
Here you can read the internal motor temperature, it’s normal
to see values from 10 to 50 °C.

PrimaLuceLab iSrl SESTO SENSO 2 user manual
Before moving SESTO SENSO 2, you have to start the
calibration. Please click on the CALIBRATION button and
you will see a new window. Move by hand the focuser
position to the innermost position of your focuser then:
1. press the “Init Calibration” button to start calibration
2. then press the “Set ZERO position” button in order to
set the 0 value of your calibration.
3. click the “Move out (!CAUTION!)” button: this will start
moving your focuser to the outer position. This will
move the focuser.
4. When your focuser is close to the outermost position,
click the “ Stop Motor and Set max limit” button. At-
tention: please remember to stop the motor BEFORE
it will reach the end of draw tube travel or you may
cause problems to the focuser or to the SESTO SEN-
SO 2 motor.
page 9
Autres manuels pour SESTO SENSO 2
2
Table des matières
Autres manuels PrimaLuceLab Moteur