TABLE OF CONTENTS
Product Overview
Safety Precautions ........................................................ 1
Introduction................................................................... 1
Price Web Server Features ............................................ 1
Package/Component Identification................................ 2
Web-Master........................................................... 2
Web Additional....................................................... 3
PRTU IP Switch ..................................................... 3
Installation & Mounting Instructions
Location........................................................................ 4
Mounting....................................................................... 5
Wiring ........................................................................... 6
BACnet MS/TP Wiring ........................................... 6
24VAC Power Wiring.............................................. 7
Network Connections ............................................ 8
Setup
Web Server Setup......................................................... 9
Creating Graphics ....................................................... 21
Creating Dashboards .................................................. 25
Tool Bar ...................................................................... 29
Creating a Trend Log................................................... 30
Viewing a Trend Log.................................................... 34
Exporting a Trend Log ................................................. 36
Creating Alarms........................................................... 37
Creating Runtimes....................................................... 41
Viewing Runtimes........................................................ 44
BACnet Router Configuration
PRTU-BAC_RTR (BACnet Router Configuration .......... 46
IP Router Configuration
IP Setup (LAN Integration) ........................................... 47
PRUT-IP-RTR (IP Router Configuration) ....................... 48
Appendix A
IT Request and Information Form ................................ 50
Hardware Specifications.............................................. 51

1
priceindustries.com |WEB SERVER - Manual
WEB SERVER
PRODUCT OVERVIEW
Safety Precautions
Short circuit or incorrect wiring may
permanently damage the controls or
other equipment. Ensure proper wiring
practices are followed. If a control failure
could lead to personal and/or property
damage, the installer must add safety/
interlock devices to protect against
these events.
Introduction
The Price Web Server is a complete BACnet front-end solution for small to medium
sized networks. The Price Web Server hosts all web pages containing graphics and
BACnet points reported by the system controllers.
The Price Web Server is accessed from any computer or smart device (tablet or
mobile phone) on the local network using a web browser. Remote access is possible
from across the globe with the use of Port Forwarding on the computer network.
Contained within the webserver are pre-loaded templates with graphics and points
lists for the popular Price controls. Changes to the graphics or the creation of new
custom graphics are supported from within the web interface.
Price Web Server can be ordered as PRTU-Front-End, which contains all of the parts
required to network all of the controls, connect them to the web server, and then
interface them to the building LAN system at a single point.
Price Web Server Features
Features of the Web Server include:
• Accessibility from any web browser on a laptop, smart phone, or tablet.
• Animated graphics
• Pre-loaded templates for Price controls
• Drag and drop setup, no programming required
• Multiple simultaneous users
• Support for Email alerts based on user-defined conditions

2WEB SERVER - Manual |priceindustries.com
WEB SERVER
Product overview
Package/Component Identification
Web-Master
Each PRTU ships with the following
items:
This package contains all the
components required for the Web
Server graphics, the parts to connect
to a single PRTU (Price Rooftop Unit
Controller) system, and those required
to connect the system to the building
computer network.
Components:
250000-920 - Price Web Server
1. PRTU-WEB
2. NETC2 cable
(to connect to PRTU-IP-RTR)
3. DIN rail
4. USB drive with manual and setup
videos
5. Price Electronics flat head
screwdriver (0.1” tip)
6. NECT12 cable
250000-931 - PRTU Bacnet Router
1. PRTU-BAC-RTR
2. NETC2 cable
(to connect to PRTU-IP-RTR)
3. DIN rail
250000-932 - PRTU IP Router
1. PRTU-IP-RTR
2. NETC12 cable
(laptop setup connection)
3. DIN rail
250000-920 - PRICE WEB SERVER
1. PRTU-WEB 3. DIN RAIL2. NETC2 CABLE
5. PRICE ELECTRONICS FLAT
HEAD SCREWDRIVER
4. USB DRIVE
250000-931 - PRTU BACNET ROUTER
1. PRTU-BAC-RTR 3. DIN RAIL2. NETC2 CABLE
250000-932 - PRTU IP ROUTER
1. PRTU-IP-RTR 3. DIN RAIL2. NETC12 CABLE
6. NETC12 CABLE

3
priceindustries.com |WEB SERVER - Manual
WEB SERVER
PRODUCT OVERVIEW
250000-933 - PRTU IP SWITCH
1. PRTU-IP-SWITCH
3. DIN RAIL
2. NETC2 CABLE
Package/Component Identification
Web Additional
The WEB-ADDITIONAL package is used
to connect additional PRTU systems to
the WEB-MASTER system.
Components:
250000-931 - PRTU Bacnet Router
1. PRTU-BAC-RTR
2. NETC2 cable
(to connect to PRTU-IP-RTR)
3. DIN Rail
PRTU IP Switch
The IP-SWITCH is required if there
are more than 3 PRTU systems being
connected to the Web Server. This
component is used to expand the “LAN”
port on the IP-RTR, allowing a further
3 PRTU systems to be connected.
See the example layout section of this
manual for further detail.
Examples:
• 1-3 PRTU Systems:
No IP Switch required
• 4-6 PRTU Systems:
Qty: 1 IP Switch required
• 7-9 PRTU Systems:
Qty: 2 IP Switch required
Components:
250000-933 - PRTU IP Switch
1. PRTU-IP-SWITCH
2. NETC2 cable
(to connect to PRTU-IP-RTR)
3. DIN rail
Please ensure you have all components
before proceeding. Inspect components
for shipping damage. Do not install
components that appear damaged.
Contact your local PRICE Sales Rep for
quick ship replacements.
As always, for the latest information and
video please visit priceindustries.com.
250000-931 - PRTU BACNET ROUTER
1. PRTU-BAC-RTR
3. DIN RAIL
2. NETC2 CABLE

4WEB SERVER - Manual |priceindustries.com
WEB SERVER
INSTALLATION & MOUNTING INSTRUCTIONS
Location
The PRTU-Front-End components should be mounted in an accessible location close to a network connection. Price suggests
mounting these components in the network or server room.
The WEB-SERVER, PRTU-IP-RTR, PRTU-BAC-RTR, and PRTU-IP-SWITCH (if applicable) should all be mounted together.
MOUNTING DETAILS
MOUNT TOGETHER IN SERVER ROOM
LONG-DISTANCE MS/TP CONNECTION
(SEE WIRING SECTION)
MOUNT PRTU / ZONE CONTROLLERS IN THEIR ZONES
PRTU-IP-RTR PRTU-BAC-RTR WEB-SERVER PRTU-IP-SWITCH

5
priceindustries.com |WEB SERVER - Manual
WEB SERVER
INSTALLATION & MOUNTING INSTRUCTIONS
Mounting
Use the included DIN rail to securely mount the PRTU-Front-
End components.
1. The Price Web Server MUST be mounted in an enclosure
2. Using 3 screws (by others) mount the DIN rail horizontally
to a secure, accessible surface.
3. Hang the Price Web Server onto the DIN rail using the
TOP white clips.
4. Using the Price Electronics screwdriver, gently pull down
on the BLACK clip, while pushing gently on the WEB-
SERVER towards the DIN rail. The Price Web Server
should click securely into place.
5. Use the mounting clips on the rear of the BAC-RTR, IP-
RTR, or IP-SWITCH to mount the components to the din
rail. Slip the top clip behind the DIN rail flange, then use
steady pressure to push the component down then back
towards the DIN rail to secure.
6. The same section of DIN rail can be used to mount
multiple components.
FRONT VIEW OF WEB-SERVER MOUNTED ON DIN RAIL
Page 8of 32
INSTALLATION AND MOUNTING
PRTU CONTROLLER
To mount the PRTU controller use the included 11” piece of DIN rail. The PRTU must NOT be installed
outdoors or inside the RTU. Mount the PRTU in the PLENUM space. Ideally near the main ductwork
discharge/return of the RTU just above the ceiling tiles.
1. Using 3 screws (by others) mount the DIN rail horizontally to a secure, accessible surface
2. Hang the PRTU controller onto the DIN rail using the TOP white clips
3. Using the Price Electronics screwdriver, gently pull down on the BLACK clip, while pushing gently
on the PRTU towards the DIN rail.
4. The PRTU should click securely into place.
5. To remove, repeat above steps in reverse
DIN Rail
Back view of PRTU
Front view of PRTU mounted on DIN Rail
BACK VIEW OF WEB-SERVER
REAR VIEW OF IP-RTR AND BAC-RTR
SAMPLE FRONT-END MOUNTING ON DIN RAIL

6WEB SERVER - Manual |priceindustries.com
WEB SERVER
INSTALLATION & MOUNTING INSTRUCTIONS
Wiring
BACnet MS/TP Wiring
Connect the BACnet MS/TP wires between the BAC-RTR(s) and their respective PRTU systems. Each system requires its own
BAC-RTR to avoid MAC address collisions.
For example, a building with 3 PRTU systems would require 3 total BAC-RTRs.
TWISTED-PAIR NETWORK CABLE (OR CAT-5).
USE 35’ PROVIDED WITH PRTU OR CABLE BY
OTHERS FOR LONG RUNS.
NETC35 CABLE (35 FOOT CAT-5 CABLE
W/ RJ-45 PLUGS) PROVIDED WITH PIC
CONNECT AS SHOWN:
+ (ORANGE/WHITE)
- (ORANGE)
SC NETCOM (BROWNS)
NOTE: TERMINAL ORDER IS DIFFERENT
ON BAC-RTR AND PRTU
PRTU-BAC-RTR
PRTU
WIRING DETAIL

7
priceindustries.com |WEB SERVER - Manual
WEB SERVER
INSTALLATION & MOUNTING INSTRUCTIONS
Wiring Continued...
24VAC Power Wiring
All components of the PRTU-Front-End package are powered by 24VAC.
WEB-SERVER BAC-RTR, IP-RTR, IP-SWITCH
24VAC HOT
COMMON
Power requirements are as follows:
• PRTU-WEB: 6VA
• BAC-RTR: 6VA
• IP-RTR: 6VA
• IP-SWITCH: 6VA
24VAC power typically from
transformer by others.
WIRING DETAILS
24VAC Polarity is critical.
HOT/Common may NOT be
swapped between devices.

8WEB SERVER - Manual |priceindustries.com
WEB SERVER
INSTALLATION & MOUNTING INSTRUCTIONS
Wiring Continued...
Network Connections
Once the BAC-RTRs have been networked to the PRTU/PIC/Prodigy controllers and the FRONT-END components have been
powered up, the IP networks can be connected and tied into the building LAN.
1. Connect the Price Web Server to one of the four “LAN” ports on the IP-RTR using the included 2 foot cable.
2. Connect the BAC-RTRs to the “LAN” ports on the IP-RTR using their included 2 foot cables.
a. If required (> 3 BAC-RTRs), the IP-SWITCH is used to expand the “LAN” ports on the IP-RTR
3. Connect the “WAN” port of the IP-RTR to the building LAN system.
NOTE: WAN port is set to DHCP by default
WEB-MASTER PACKAGE
IP-RTR
WEB-SERVER BAC-RTR BAC-RTR BAC-RTR BAC-RTR
IP-SWITCH
(ONLY REQUIRED IF > 3 BAC-RTRS)
TO BUILDING LAN