Preco PreView CD6102 Manuel utilisateur

PreView®Display
CD6102 / CD6102 OC / CD6102-2
Operating Manual
www.preco.com




Contents
Operator Display Description..........................................1
Display Unit Function .....................................................2
Mounting Instructions ....................................................2
Troubleshooting.............................................................3
Specifications................................................................4
Warranty Information.....................................................5
PreView®Add-on Options: ..............................................6

PATENTS
Patented under one or more of the following U.S. Patents:
5345471, 5523760, 5457394, 5465094, 5512834, 5521600, 5682164, 5630216,
5510800, 5661490, 5609059, 5774091, 5757320, 5581256, 5832772, 5519400,
5767953, 5767627, 5589838, 5563605, 5661385, 5517198, 5610611, 5883591,
5805110, 5754144, 7088284, and 7215278.
Other patents have been applied for.
TRADEMARKS
The names of actual companies and products mentioned herein may be the trademarks of their
respective owners. Any rights not expressly granted herein are reserved.

+1.866.977.7326 www.preco.com 3700046C
Copyright 2016
Page 1
Operator Display Description
CD6102–the CD6102 operator display family is a Common Display used
with all the PreView® CAN based sensors. This display provides the vehicle
operator with a visual indication of a detected object. The display unit also
contains a buzzer to provide an audible alert that will increase in rate as an
object becomes closer, providing the operator with another cue that an
object is being detected.
A switch is provided on the front panel of the display allowing the vehicle
operator the ability to adjust the buzzer volume to three different levels or to
provide an alarm acknowledge and silence the buzzer.
CD6102-2 –is a CD6102 display factory configured for a two sensor
PreView® system.
CD6102 OC –is a CD6102 display sealed for an open cab application.
This display does not contain a switch to adjust the volume.
The operator display continuously monitors communication from the
PreView® sensor and in the event of a system failure or malfunction, will
notify the operator with a fault indication.
The PreView®system is a blind spot collision warning system
designed to supplement other safety practices and/or devices.
The machine operator is always the first line of defense when
safely operating a vehicle.

+1.866.977.7326 www.preco.com 3700046C
Copyright 2016
Page 2
Display Unit Function
Item
Description
Status LED
Illuminates green continuously after power is applied to the system. The
status will change from green to red if a system malfunction occurs.
Range
Indications
Illuminates to give operator a relative distance measurement to the closest
detected object. LED’s operate from the left to right, with a closer object
resulting in more LED’s illuminated.
Display Buzzer
Sounds audible tones to alert operator of obstacles. The speaker pulse
rate will increase as the vehicle gets closer to an object.
Volume
Control/Ack
Switch*
This momentary push button switch allows three different buzzer volume
levels to be selected. It can also be configured as an acknowledge switch
to silence the buzzer using the Service Tool.
Table 1. Operator Display Description
*CD6102 OC display does not contain a Volume Control / Ack Switch
Mounting Instructions
Display Unit Installation
The display unit should be mounted where the vehicle operator can easily
view it while backing. The ideal location for this is on the dash positioned by
either windshield pillar. This will allow the operator view of the display while
also looking out one of the side mirrors.
The PreView® display unit comes equipped with a mounting bracket and
hardware. If desired, the display unit can be mounted to the display bracket
with the supplied hardware. This bracket can then be mounted in the
vehicle cab as desired.
The display receives power from the sensor. See installation guide and
supplied manuals for more information.
Display Buzzer
Volume Control/
Ack Switch*
Status LED
Range Indications
5 Zones
LED #5
LED #1

+1.866.977.7326 www.preco.com 3700046C
Copyright 2016
Page 3
Troubleshooting
Display Status LED is not illuminated.
Verify that DC power (9-33V) is applied to the sensor.
Verify that the cable between the sensor and display is connected.
Display Status LED is RED.
Check connection between display and sensor.
Display Status LED is RED and one Yellow LED is illuminated.
LED Error Code
Possible Reason
LED #5 on
No communication with any sensor(s)
LED #4 on
Built in Self Test Error –Contact Factory
LED #3 on
Missing sensor(s)
All 5 Yellow LEDs on
Blockage Error*
All the display LED’s are illuminated when sensor is mounted.
Verify the sensor is pointing outward from the vehicle in an open
area with no obstructions. This may require removing the mounting
screws and lifting the sensor out away from the rear of the vehicle.
If the display LED’s are not active when moved away from the
vehicle, but are active when mounted, then the sensors mounting
position will have to be moved.
Sensor is detecting the ground, indicated by a few of the display LED’s
being lit.
In an open field, either move the sensor up higher or slightly angle
the sensor upward 5 to 10 degrees. The minimum recommended
mounting height is 24 inches.
*Blockage Error only reported by Sentry sensors.
For questions, call +1.844.787.2327 toll free in the USA. Call
+1.208.323.1000 or send a fax request to +1.208.323.1034 for outside
the USA, or submit an online request at www.preco.com/contact-us/
A safety specialist will respond within 24 hours.

+1.866.977.7326 www.preco.com 3700046C
Copyright 2016
Page 4
Specifications
DISPLAY SPECIFICATIONS (Typical)
Housing Material: Polycarbonate/ABS alloy
Dimensions: 1.00”H x 2.25"W x 2.00"D (2.5cm x 5.7cm x 5.1cm)
Weight: 0.25 lb. (0.11 kg)
Mounting: User dependent
ELECTRICAL SPECIFICATIONS
Power supplied by sensor
OPERATING CHARACTERISTICS
Warning Ranges: 5 zones
COMMUNICATION
Physical Layer: CAN 2.0B, 250 KB/s
Protocol Layer: SAE J1939 Extended
Data Update Rate: 70 ms
PRODUCT MANUFACTURED IN THE USA
PIN
SIGNAL NAME
1
CAN HIGH
2
CAN LOW
3
-
4
-
5
POWER
6
GROUND
7
-
8
-
MATING END VIEW
CONNECTOR PIN OUT
1
8
7
Ce manuel convient aux modèles suivants
2
Table des matières
Autres manuels Preco Moniteur