Postium OBM-P180 Guide de démarrage rapide

Operational Instructions
OBM-P180
OBM-P210
OBM-P240
OBM-P310
OBM-P420
OBM-P460
OBM-P550
User Manual
06. 2017
OBM P Series
True Dual Monitoring Solutions

Table of Contents
1. Precaution
2. Main Features
3. Location and Function of Parts and Controls
Front Panel
Rear Panel
4. Using the Menu
5. Adjustment Using the Menus
6. OSD Menu
Operations Status Menu
Color Temp/Color Space/Gamma Menu
Zebra/Focus Menu
User Conguration Menu
Remote Menu
Security Menu
7. PBP Mode
8. Other Functions
9. Available Signal Formats
10. Product Specications
3
5
6
8
10
11
13
14
16
15
20
21
22
24
26
28
O
BM-P Ser
i
es
2
True Dua
l
Monitoring So
l
ution
s
Picture B
y
Pictur
e

OBM-P Ser
i
e
s
3
True Dua
l
Monitoring So
l
ution
s
Picture B
y
Pictur
e
1. Precaution
Always use set voltage.
AC 100 ~ 230V, 50/60Hz
DC 12V(OBM-P180/P210/P240) or DC 24V(OBM-P310)
All these instrucons should be read and understood before operang the unit.
If liquid is spilled on or impacts this product, please disconnect the product immediately and seek profession-
al help before connued use.
Unplug the unit from the wall outlet if it is not to be used for several days or more.
Keep unit in a well-venlated place to prevent overheang.
Do not install the product near any heat-generang equipment. Also, keep the product out of direct sunlight
or dusty areas.
Protect the power cord from being walked on or pinched parcularly at plugs, convenience receptacles, and
the point where they exit from the apparatus.
When using other DC 12V(OBM-P180/P210/P240) or DC 24V(OBM-P310) adapters instead of the standard
adapter provided by the manufacturer, please check the proper load capacity or current capacity and use an
adapter with stable voltage.
Do not overload AC outlets or extension cords. Overloading can cause fire or electric shock.
A very small proporon of pixels may be stuck, either always off (black), always on (red, green, or blue), or
flashing. In addion, over a long period of use, because of the physical characteriscs of the liquid crystal
display, such stuck pixels may appear spontaneously. These problems are not a malfuncon.
If a fixed picture such as a frame of a divided picture or me code, or a sll picture is displayed for a long me,
an image may remain on the screen and be superimposed as a ghosng image.
The permanent burn-in may occur for LCD panel if sll images are displayed in the same posion on the
screen connuously, or repeatedly over extended periods.
To reduce the risk of burn-in,
a. Turn off the character displays.
b. Turn off the power when not in use.
c. Turn off the power if the monitor is not to be used for a prolonged period of me.

O
BM-P Ser
i
e
s
4
True Dua
l
Monitoring So
l
ution
s
Picture B
y
Pictur
e
Do not aempt to service the product yourself. Removing covers can expose you to high voltage and other
dangerous condions. Request a qualified service person to perform servicing.
When the product needs replacement parts, make sure that the service person uses replacement parts
specified by the manufacturer, or those with the same characteriscs and performance as the original parts.
Use of unauthorized parts may result in fire, electric shock and/or other danger.
Only clean the product with a noncommercial, mild and neutral detergent.
Do not throw away the carton and packing materials. When transporng the product, make use of its original
packaging for safer carriage.
FCC (Federal Communications Commission)
This equipment has been tested and found to comply with the limits for class A digital device, pursuant
to part 15 of the FCC Rules. These limits are designed to provide reasonable protecon against harmful
interference when the equipment is operated in a commercial environment. This equipment generates,
uses, and can radiate radio frequency energy, and if not installed and used in accordance with the
instrucon manual, may cause harmful interference to radio communicaons. Operaon of this
equipment in a residenal area is likely to cause harmful interference in which case the user will be
required to correct the interference at his own expense.
Warning!! : Changes or modificaons not expressly approved by the manufacturer could void the
user’s authority to operate the equipment.
Disposal of Old Electrical & Electronic Equipment
(Applicable in the European Union and other European countries
with separate collecon systems)
This symbol on the product or on its packing indicates that this product shall not be treated as
household waste. Instead it shall be handed over to the applicable collecon point for the recycling of
electrical and electronic equipment. By ensuring this product is disposed of correctly, you will help
prevent potenal negave consequence for the environment and human health, which could otherwise
be caused by inappropriate waste handling of this product. The recycling of materials will help to
conserve natural resources.
!

O
BM-P Serie
s
5
T
rue Dua
l
Monitoring So
l
utions
Picture B
y
Pictur
e
2. Main Features
The OBM P series incorporates the dual scaler, which enables to display the two different SDI signals on the
screen. And, the OBM P series can display Waveform and Vector Scope on the two different SDI videos
respecvely, which is very useful and convenient for dual monitoring. Posum’s OBM P series offers the
superior picture quality and wide viewing angle, and includes an array of professional features and the
advanced audio & video signal analysis funcons. The OBM P series is equipped with various I/O interfaces
such as 3G-SDI, HDMI, Component, Composite.
· 3G/HD/SD-SDI 2 Channel
· PBP(Picture-by-Picture) Funcon
· 1:1 Scan in PBP Mode
· Color Sengs Adjustable to Either of Two Images in PBP Mode
· Dual Waveform Monitor & Vector Scope
· HDR(High Dynamic Range) Display supporng PQ EOTF(ST 2084), Hybrid Log Gamma, S-Log3
· 3D-LUT for Accurate Color Reproducon
· 1.064 Billion Colors
· Camera Log Conversion
· Camera Log Mapped SDI Loopout
· Custom 3D LUT File Import Through USB
· Gamma Selecon (1.0 ~ 3.0)
· Color Temperature(3200K, 5500K, 6500K, 9300K, USER 1/2/3, DCI-P3)
· Compare Color Sengs (Side by Side, Wipe Posion)
· Monitor Control via Ethernet, RS-422
· Zero Scan / Over Scan / 1:1 Scan
· Easy Firmware Update by USB
· Fast Mode
· Focus Assist
· Zebra
· HDR Waveform
· De-embedded 8~16ch Audio Level Meter
· Remote Control via GPI(RJ-45) Port
· White Internal Paerns Display for Color Test
· 3 Color TALLY Lamp
· Rack & VESA Mount (Opon)
· Closed Capon(608, 708)
· System Data Copy
· Key Lock & Password Lock
· Aspect
· Freeze
· H/V Delay
· Blue/Mono Only
· Time Code Display
· IMD

O
BM-P Serie
s
6
T
rue Dua
l
Monitoring So
l
ution
s
Picture B
y
Pictur
e
3. Location and Function of Parts and Controls
Front Panel
A : Input select Buons/Lamp
Press to monitor the signal input to each connector.
[SDI] Buon/Lamp
- Press the buon to select SDI input.
- The mode changes in the order of [3G SDI-1], [3G SDI-2]
[ANALOG] Buon/Lamp
- Press the buon to select Analog input.
- The mode changes in the order of [COMPOSITE], [COMPONENT].
[HDMI] Buon/Lamp
- Press the buon to select HDMI input.
[PBP] Buon/Lamp
- Press the buon to select the PBP(Picture-by-Picture) funcon.
B : F1 ~ F5 Buon/Lamp
Press to adjust or turn on/off the assigned funcon.
The following funcons are assigned at the factory.
[F1]: Color Space Compare
[F2]: H/V Delay
[F3]: Color Temp
[F4]: Audio Level Meter
[F5]: Time Code
C : Funcon Buon/Lamp
Press to adjust or turn/off each funcon.
[SCAN] Buon - Press the buon to adjust the scan mode. (Zero Scan, 1:1 Scan, Over Scan).
[ASPECT] Buon
- Press the buon to select the Aspect Rao of the signal.
- Mode changes in the order of [16:9] [4:3] [2.35;1] [1.85:1] [15:9] [16:10] [AUTO].
[MARKER] Buon - Press the buon to acvate and deacvate the Marker.
[BLUE ONLY] Buon
- Press the buon to acvate and deacvate the Blue Only funcon.
- You may remove R(red) and G(green) from the input signal and play the screen only with B(blue) signal.
This funcon is convenient to adjust Chroma and Phase and to observe the signal noise.
- The buon may be pressed twice to change the screen to MONO mode.
(This mode uses only Luminance value)
[Screen Select] Buon
- Press the buon to select the le side or the right side screen in P&P Mode.
- [Le Side], [Right Side], [All] are selected in order.
D : Rotary encoder
[BRIGHT] knob
Press this knob to display the adjustment screen and adjust the picture brightness. Press again to hide the
adjustment screen. Turn the knob right to increase the brightness and turn le to decrease it.
[CONTRAST] knob
Press this knob to display the adjustment screen and adjust the picture contrast. Press again to hide the
adjustment screen. Turn the knob right to increase the contrast and turn le to decrease it.
**If you push and hold the knob for a second, the seng values of the know are inialized.
AB C D E F G

O
BM-P Serie
s
7
T
rue Dua
l
Monitoring So
l
utions
P
icture B
y
Pictur
e
[CHROMA] knob
Press this knob to display the adjustment screen and adjust the color intensity. Press again to hide the
adjustment screen. Turn the knob right to increase the color intensity and turn le to decrease it.
[APERTURE] knob
Press this knob to display the adjustment screen and adjust the picture sharpness. Press again to hide
the adjustment screen. Turn the knob right to make the picture sharper and turn it le to make the
picture soer.
E : Menu Operaon Buons
Displays or sets the on-screen menu.
[MENU/RETURN]
- Acvates and deacvates the display of the Main Menu.
- When the on-screen menu is not displayed, if this buon is pressed the main menu is displayed.
When the menu is displayed, press the buon to return to the previous menu.
[SELECT/VOLUME] knob (Menu selecon control)
- When the menu is displayed, turn the knob to select a menu item or seng value, and then press the
knob to confirm the seng.
- If the menu is not displayed and this knob is pressed, the adjustment screen of [VOLUME] is displayed
to adjust the audio volume.
- Press this knob to change the modes in the order of [Focus Frequency] [Zebra Level] [Line Posion]
[Variable Marker] and adjust each mode’s value.
[Focus Frequency]: When Focus Assist funcon is acvated, this mode is displayed.
[Zebra Level]: When Zebra funcon is acvated, this mode is displayed.
[Line Posion]: When WFM/Vector funcon and Line Select funcon is acvated, this mode is displayed.
[Variable Marker]:
When Marker funcon is acvated and Aspect Marker is set Variable, this mode is displayed.
[Wipe Posion] : When [Wipe] is set to on, this mode is displayed.
F : (Standby) switch and indicator
- Press to turn the power on when this monitor is in standby mode. Aer being turned on, the monitor
performs inializaon and the indicator flashes in green.
- Press the switch again for a second to set the monitor in standby mode. Then, the indicator flashes in
orange and then turns red. The indicator in orange means that the monitor goes into the standby
mode.
When the indicator flashes in orange, this buon doesn’t work.
G : (headphone) jack & Speaker and USB connector
Headphone jack & Speaker
- The audio signal which is selected using the input select buon is output in stereo sound.
- When SDI signals are input, the audio signals of the channels selected with SDI Audio Seng in the User
Configuraon menu are output.
- When the headphones are connected to the jack, audio signals will not be output.
[USB] Connector
- To update CPU, GPU, FPGA program.
- To connect the monitor with the Color Calibraon program provided by the manufacturer and perform
the color calibraon.
- To connect the monitor with the control program provided by the manufacturer and control funcons
remotely.
- Custom 3D LUT File Import via USB memory sck or pc(*.cube, 33^3, 65^3)

O
BM-P Serie
s
8
T
rue Dua
l
Monitoring So
l
ution
s
P
icture B
y
Picture
Rear Panel
A : SDI IN (SDI Input) connectors (BNC)
Input connectors for SDI signals. For details, see “Connecng the SDI Signals” (page 26).
B : SDI OUT (SDI Output) connectors (BNC)
Output connectors for SDI signals.
Each connector outputs the signal which is input to the corresponding SDI IN connector.
**Note - Output is acvated only when the power is on. Output is not acvated in standby mode.
C : HDMI input connectors
Input connectors for HDMI signals.
D : Analog input connectors
Input connectors for analog signals (CVBS, Component).
E : PARALLEL REMOTE connector(RJ-45, 8-pin)
Forms a parallel switch and controls the monitor externally.
**Note - For safety, do not connect the connector for peripheral device wiring that might have excessive
voltage to this port. Follow the instrucons about this port.
[Pin Assignment]
Funcons can be changed in [Remote] secon of the menu.
18
Pin Number Funcon
SDI
HDMI
Analog
PBP
1:1 Scan
Aspect
Power
GND
1
2
3
4
5
6
7
8
A
BCDFEH
G
AUDIO
IN
HDMI-IN
Y(CVBS1)
Pb Pr
Ethernet
REMOTE
RS422 IN
RS422 OUT
IN
OUT
SDI-1 SDI-2

O
BM-P Ser
i
e
s
9
True Dua
l
Monitoring So
l
ution
s
Picture B
y
Pictur
e
DC IN Socket
1 : GND
4 : +12V
4
12
3
DC IN Socket
1 : GND
4 : +24V
4
12
3
F : SERIAL REMOTE IN/OUT connector (RJ-45)
Used for the future funcon expansion.
Connects the monitor to the control program provided by the manufacturer by using RS-422/485
communicaon or the external UMD(IMD) equipment and controls the monitor.
G : LAN(10/100) IN/OUT connector
Used for the future funcon expansion.
Connects to the LAN (10/100) connector of the network by using 10BASE-T/100BASE-TX LAN cable.
A daisy chain connecon using the LAN input/output connectors enables the control of mulple monitors in
sequence.
H : AUDIO IN connector (Stereo mini jack)
Connector for analog audio input.
Analog input can be selected with SDI Audio Seng in User Configuraon menu.
I : DC IN terminal
Connects the DC power supply to the monitor.
- OBM-P180 / 210 / 240 : 12V
- OBM-P310: 24V
Make sure to use DC 12V power supply for OBM-P180/210/240 and DC 24V power supply for OBM-P310.
OBM-P180/210/240 OBM-P310
J : AC IN terminal
AC power input connector.
Connects the provided AC power cord.

O
BM-P Ser
i
e
s
10
True Dua
l
Monitoring So
l
ution
s
Picture B
y
Pictur
e
4. Using the Menu
2. Turn SELECT/VOLUME knob to select a menu,
then press the knob.
The menu icon presently selected is shown highlighted.
This monitor is equipped with an OSD menu to make various adjustments and sengs such as picture control,
input seng, set seng change, etc.
1. Press the MENU buon.
The menu appears.
The menu presently selected is shown in gray.
3. Select an item.
Turn SELECT/VOLUME knob to select the item, then press the knob.
The item to be changed is shown highlighted, and the sub menu is displayed on the right.
4. Make the seng or adjustment on an item.
How to change the adjustment level:
To increase the level, turn the SELECT/VOLUME knob right.
To decrease the level, turn the SELECT/VOLUME knob le.
How to change the seng:
Turn the SELECT/VOLUME knob to change the seng, then press the knob to confirm the seng.
**Note - An item displayed in gray cannot be accessed. The item is accessible if it is displayed in white.
To return the display to the previous screen
Press the MENU buon.
To clear the menu
Press the MENU buon.
Ce manuel convient aux modèles suivants
6
Table des matières

















