Pollmeier SE Touch-to-open Manuel utilisateur

Instruction manual
Electric glass door lock
Touch-to-open

Operating instructions draft | 09-2017_v1
OPERATING INSTRUCTIONS
Touch to open electric glass door lock

1
Content
1 General
1.1 Performance Description as per the Building Product Ordinance
1.2 EC Declaration of Conformity
2
3
4
2 Description of the Electric Glass Door Lock
2.1 Technical Data
2.2 Function
5
6
6 Removal & Disposal 19
7 Approved Handles 19
4 Installation
4.1 Installation of the Door Hinges
4.2 Installing the Glass Door Lock
10
12
13
5 Operation and Maintenance
5.1 Troubleshooting
5.2 Emergency Release
5.3 Cleaning
5.4 Replacing the Batteries
14
15
16
17
17
3 Security
3.1 Intended Use
3.2 Unintended Use
8
8
9

2
OPERATING INSTRUCTIONS
Touch to open electric glass door lock
1 General
Please read through these operating instructions carefully before fitting or using the
product. They contain important instructions on safety which help to avoid risks, errors and
malfunctions. Keep the instructions in a safe place.
The manufacturer's warranty is voided in any case of change, extension and modification
(mechanical or electrical) of the electric glass door lock, opening the casing, or damage
caused by use of force.
The scope of supply includes:
• the electric glass door lock
• four AA Mignon alkaline batteries (1.5 V)
• three M5 x 16 countersunk screws with 3mm hexagon socket
• a design trim panel for the inside of the hinge
• a design trim panel for the outside of the hinge
• two office hinges with hinge pins
• two cover caps with clamping plates
• two frame parts
• four M6 x 20 countersunk screws with 4mm hexagon socket

3
1.1 Declaration of Performance
Declaration of Performance as per Annex III of (EU)
Ordinance no. 305/2011 (Building Product Ordinance)
1. Type:
2. Intended use:
3. Manufacturer:
4. Authorised representative:
5. System for evaluation and verification
of performance:
6. Harmonised standard:
7. Declared performance:
Electric glass door lock
Touch to open - EGS1
Motorised actuation of the latch in
single-leaf, interior glass doors
Baugruppentechnik Pollmeier GmbH,
Hövelrieger Str. 26, D-33161 Hövelhof
. / .
4
EN 14846:2008
Feature Performance
Use category:
Continuous operability and load on latch
Door mass and closing force
Suitability for use in fire protection/smoke protection doors
Security
Corrosion resistance, temperature, humidity
Protection and drill open resistance
Protection of electrical function
Protection against electrical manipulation
N/A*
S
N/A*
0
None
0
0
0
1
8. Legally binding declaration
The performance of the above mentioned product as per no. 1 complies with the declared
performance as per no. 7. The manufacturer stated above is exclusively responsible for
creating this declaration in compliance with (EU) Ordinance no. 305/2011.
* Deviates from the standard as a glass door lock
Hövelhof, 1 June 2017

4
1.2 EC Declaration of Conformity
EC Declaration of Conformity BGP 09-2017
pursuant to the EC Machinery Directive 2006/42/EC
to which this Declaration relates, complies with all applicable provisions of EC Directive
2006/42/EC – Machinery Directive.
The machine also complies with the provisions of EU Directive 2004/108/EC - Electroma-
gnetic Compatibility - and adheres to the protection objectives of the Low Voltage Directive
2006/95/EC as per Annex I, no. 1.5.1 of Machinery Directive 2006/42/EC.
The technical documentation exists in full; the operating instructions which belong to the
machine exist in the original version.
The authorised representative for compiling the technical documentation is:
Development Department, Baugruppentechnik Pollmeier GmbH, Hövelrieger Strasse 26,
33161 Hövelhof, Germany
Designation:
Type:
Serial number:
Touch to open electric
glass door lock - EGS1
See product label
Baugruppentechnik Pollmeier GmbH, Hövelrieger Str. 26, 33161 Hövelhof, Germany,
hereby declares in sole responsibility that the following machine
OPERATING INSTRUCTIONS
Touch to open electric glass door lock
Hövelhof, 1 June 2017

62
129 15
5
Outside of the hinge door lock dimensions:
Inside of the hinge door lock dimensions:
Weight:
Protection class:
Power supply:
Width: 145mm / depth: 15mm / height: 62mm
Width: 129mm / depth: 15mm / height: 62mm
500g incl. batteries / 600g without batteries
IP 20
4 x AA Mignon alkaline batteries (1.5V)
2.1 Technical Data
Electric glass door lock
Outside of the hinge
Electric glass door lock
Inside of the hinge
62
28
145 15
10,4
8,8
Battery compartment
On/off switchEmergency release
Emergency release catch

6
3 Security
3.1 Intended Use
– The lock is designed for occasional use in private interior rooms by persons who handle
the technology carefully.
– The lock is exclusively designed for installation in single-leaf glass room doors in conjuncti-
on with a wooden or aluminium frame.
– The door weight must not exceed 60 kg.
– Only use design trim panels licensed by Baugruppentechnik Pollmeier GmbH in conjuncti-
on with the electric glass door lock as the function cannot otherwise be guaranteed (see
section 7).
– The glass door lock may only be used with 8mm ESG panels.
– Only use the lock in undamaged condition without defects. Exclusively use the supplied
batteries, or equivalent (type AA 1.5 V Mignon alkaline batteries).
The A-rated emitted sound pressure level is less than or equal to 70 dB(A). There is no risk
from noise.
The maximum effective value of the weighted acceleration to which the entire body is
exposed is less than 0.5 m/s². The overall vibration value to which the upper body limbs are
exposed is less than 2.5 m/s². Thus, there is no risk due to vibration.
2.3 Function
When the glass door is closed, the latch is pulled out of the lock by the magnetic strike
plate and snaps into place in the strike plate.
When the contact surfaces are actuated, the locking part (latch) on the lock is electrically
retracted. The motor overcomes the magnetic attraction force and pulls the latch out of
the strike plate. The door can be open by pushing or pulling.
OPERATING INSTRUCTIONS
Touch to open electric glass door lock

7
Caution! Use of the electric glass door lock in doors that are located on an
identified escape and emergency route or in smoke or fire protection doors is
not intended and not permitted!
Caution! Do not use the electric glass door lock for frequently used doors in
public buildings or rooms to which access needs to be secure.
Caution! Do not use the lock in saunas or steam rooms!
Caution! One-sided handle installation is forbidden. Always fit a handle on each
side of the door!
Caution! No not insert objects into the lock's openings! Do not force open the
lock case!
Any use of the electric glass door lock other than the intended use will void your warranty.
Baugruppentechnik Pollmeier GmbH accepts no liability for any damage caused in this way.
For this reason, you must comply with the following directions:
3.2 Unintended Use

8
OPERATING INSTRUCTIONS
Touch to open electric glass door lock
4.1 Installation of the Door Hinges
1. Insert the frame parts "A" into the intended bore holes in the frame. A uniform distance of
4mm should be set between the hinge and frame part. Fix the frame parts in the door frame
hinge using the screws.
2. Insert the glass drilling protective sleeves "B" into the glass drilling holes of the door leaf.
Position clamping plate "C" and sash hinge "D" on each side above the glass drilling protec-
tive sleeves on the door leaf. The counterbores on the clamping plate must face outwardly.
Consider whether the door is mounted DIN R or DIN L. Insert the attachment screws "E"
through the clamping plate and door leaf and screw to the sash hinge. Tighten the screws
with a torque of 14Nm once you have aligned the sash hinge at a right angle to the glass
edge.
3. Lift the door leaf with sash hinges onto the frame parts mounted on the frame and fix in
place using the hinge pins "F". The groove on the hinge pin must be completely inserted at
Before fitting, check all parts for completeness and signs of damage. If you see any damage
that could impair the lock's functionality, do not fit the lock under any circumstances! Fitting
must be performed by a skilled person.
A: Frame part
B: Glass drilling protective
sleeves
C: Clamping plate
D: Sash hinge
E: Attachment screws
F: Hinge pin
G: Grub screw
H: Cover cap
A
F
G
B
E
H
C
D
the height of the grub screw in the sash hinge. Use the grub screws to secure the hinge pins
against sliding out.
4. Remove the protective films from the adhesive strips on the inside of the cover caps "H"
and stick the cover caps to the middle of the clamping plates.
Autres manuels pour SE Touch-to-open
1
Ce manuel convient aux modèles suivants
1
Table des matières
Autres manuels Pollmeier Système de sécurité
Manuels Système de sécurité populaires d'autres marques

EDM
EDM Solution 6+6 Wireless-AE Manuel utilisateur

Highway Safety Group
Highway Safety Group EA401 Manuel utilisateur

Siren
Siren LED GSM Manuel utilisateur

Detection Systems
Detection Systems 7090i Instructions de montage

Se-Kure Controls
Se-Kure Controls MicroMini SK-4841 Manuel utilisateur

Siemens
Siemens FDM273 Manuel utilisateur