pleasant hearth ZCB100 Manuel utilisateur

1
INSTALLER: Leave this manual with the appliance.
CONSUMER: Retain this manual for future reference.
IMZCB - 2022-11-18
Zero Clearance Blower
MODEL #: ZCB100
Questions, problems, missing parts?
Before returning to your retailer, call our call our customer service depart-
ment at 1-877-447-4768, 8:30 a.m. – 4:30 p.m., CST, Monday – Friday or
IMPORTANT INSTRUCTIONS
PLEASE READ THIS MANUAL BEFORE INSTALLING AND USING APPLIANCE
WARNING: IF THE INFORMATION IN THIS MANUAL IS NOT
FOLLOWED EXACTLY, A FIRE OR EXPLOSION MAY RESULT
CAUSING PROPERTY DAMAGE, PERSONAL INJURY OR LOSS OF
LIFE.
WARNING: THIS PRODUCT IS ONLY FOR USE WITH MODELS
SPECIFIED IN THIS MANUAL BY THE MANFACTURER. ANY OTHER
USAGE OR INSTALLATION NOT SPECIFIED IN THIS MANUAL IS
PROHIBITED.
WARNING
This Product can expose you to chemicals including Diisononyl phthalate (DINP) which is known
to the State of California to cause cancer and Di-isodecyl phthalates (DIDP) which is known to the
State of California to cause developmental harm.
For more information go to www.p65Warnings.ca.gov


3
PACKAGE CONTENTS
PREPARATION
PARTS LIST
Before beginning assembly of product, make sure all parts are present.
Compare parts with package contents list and diagram under. If any part is
missing or damaged, do not attempt to assemble, install or operate the product.
Contact our Technical Service Department at 1-877-447-4768.
Before beginning assembly of product, make sure all parts are present. Com-
pare parts with package contents list and hardware contents above. If any part is
missing or damaged, do not attempt to assemble the product. Contact customer
service for replacement parts.
Estimated Assembly Time: 15 minutes
Tools Required for Assembly: Phillips screwdriver (not included).
A
B
REF # PART # DESCRIPTION QUANTITY
A XB002-01Q Blower 1
B M4.2×8 Screw 4

4
WARNING: This appliance is equipped with a three-prong (grounding) plug for
your protection against shock hazard and must be plugged directly into a properly
grounded three-prong receptacle.
1. Read all instructions before using this appliance.
2. If possible always unplug this appliance when not in use.
3. Do not operate any appliance with a damaged cord or plug or after the ap-
pliance malfunctions, has been dropped or damaged in any manner.
4. Undernocircumstancesshouldthisappliancebemodied.Partshavingto
be removed for servicing must be replaced prior to operating this appliance
again.
5. Do not use outdoors.
6. Do not run the cord under carpeting. Do not cover the cord with throw rugs,
runnersorthelike.Arrangecordawayfromtrafcareasandwhereitwill
not be tripped over.
7. To disconnect this appliance, make sure the log set is off and then remove
plug from outlet.
8. Connect to properly grounded outlets only.
9. This appliance, when installed, must be electrically grounded in accor-
dance with local codes, with the current USA installations, or in the ab-
sence of local codes, the National Electric Code, ANSI/NFPA No. 70.
10. Use this appliance only as described in this manual. Any other use not
recommendedbythemanufacturermaycausere,electricshockorinjury
to persons.
11. Installationandrepairshouldbedonebyaqualiedserviceperson.The
appliance should be inspected before use and at least annually by a pro-
fessional service person. More frequent cleaning may be required due to
excessive lint from carpeting, bedding material, etc.
SAFETY INFORMATION SAVE THESE INSTRUCTIONS

5
NOTE: If you are installing the zero clearance blower on models PHZCI28NG, PHZCI28LP, PHZCI32NG,
PHZCI32LP, please proceed to page 5.
NOTE: If you are installing the zero clearance blower on PHZC32C, PHZC36C, and PHZC42C models, refer
to the installation instructions provided with the kit for electrical wiring requirements, or the blower installation
section. The rebox must be connected to a main power supply at the time of the rebox installation. The
electrical connections must be made before the rebox is framed and enclosed in the nished walls. For the
most convenient installation, install the blower PRIOR to the installation of the vent-free heater. As long as
electrical connections have been installed at the time of the rebox installation, the blower can be installed
later. Please refer to your rebox owners manual for more information about the electrical connection.
NOTE: If an electrical connection has NOT been installed in the rebox, the blower CANNOT be
installed.
WARNING!
Electrical connections should only be per-
formed by a qualied, licensed electrician.
Main power must be off when connecting to
the main electrical power supply or perform-
ing service.
The blower, when installed, must be elec-
trically grounded in accordance with local
codes or in the absence of local codes, with
the National Electrical Code ANSI/NFPA 70.
ZCB100 Blower Kit
Blower Mounting Bracket
Lower Grill Assembly
(4) #8 Sheet Metal Screws
(4) Sheet Metal Screws
Included in Blower Kit)(
Electrical Box: (Electricity
and outlet must be installed
prior to installing the blower.
Installing a single pole switch
is recommended.) Plug
blower in here
Figure 15 - Blower Installation
Blower Installation Instructions:
1. Lower the bottom grill assembly and remove
the blower mounting bracket attached to the
inner back wall of the rebox with a #2 phillips
screw driver.
2. Attach the blower to the bracket with the (4)
sheet metal screws included in the blower kit
as shown in Figure 15.
3. Re-install the bracket insuring the blower
outlet is pointed upward.
4. Plug in the cord to the properly grounded
3-prong receptacle.
WARNING!
Never use an extension cord to power the blower.
POWER CORD
MOTOR
BLACK
GREEN
WHITE
IF ANY ORIGINAL WIRING SUPPLIED
WITH THIS HEATER MUST BE REPLACED,
IT MUST BE TYPE AWG 105C WIRE OR ITS
EQUIVALENT EXCEPT AS INDICATED.
EARTH (SHELL)
PLEASANT HEARTH ZERO CLEARANCE FIREBOX BLOWER INSTALLATION INSTRUCTIONS
PHZC32C, PHZC36C, or
PHZC42C zero clearance rebox

6
1. Remove top grill (if frame is not already removed).
Screws
2
3. Assemble the zero clearance blower and the
removed bracket together by screwing x4 screws into
the top of the bracket.
CAUTION: Label all wires prior to disconnection when servicing controls. Wiring errors can cause
improper and dangerous operation. Verify proper operation after servicing.
NOTE: If any of the original wire as supplied with the appliance must be replaced, it must be replaced with a
wire of at least an equal temperature rating.
NOTE: The rebox must be connected to a main power supply at the time of the rebox installation. If an elec-
trical connection has not been installed in the rebox, the blower will NOT be able to be installed. Please refer
to your rebox owners manual for more information about the electrical connection.
If you are installing the zero clearance blower on models: PHZCI28LP / PHZCI28NG / PHZCI32LP /
PHZCI32NG, please follow the instructions below.
2. Remove bracket from top vent by unscrewing x4
screws. Set these screws aside to use again later.
3
1
AA
ZCB100 Blower kit
Hardware Used
AA M4. 2x8 Screws x 4
PLEASANT HEARTH GAS FIREPLACE INSERT BLOWER INSTALLATION INSTRUCTIONS
NOTE: If an electrical connection has NOT been installed in the rebox, the blower CANNOT be
installed.

7
BLOWER MOUNTING LOCATION
5
4. Reinsert the blower and bracket assembly
into the top vent and screw in the 4 previously
removed screws into the back of the replace
cabinet. Screws
4
5. Route the blower cord through the race way.
Electrical Box: (Electricity and outlet must be
installed prior to installing the blower. Installing a
single pole switch is recommended.) Plug blower
in here.
BLOWER MOUNTING LOCATION
6
6. Reassemble top grill (if frame is not already
removed).
INSTALLATION
BLOWER BLACK
WHITE
GREEN
BLOWER WIRING DIAGRAM
Install a NEMA 5-15R
receptacle for power supply
IF ANY ORIGINAL WIRING SUPPLIED
WITH THIS HEATER MUST BE
REPLACED, IT MUST BE TYP AWG
105C WIRE OR ITS EQUIVALENT
EXCEPT AS INDICATED.
raceway
FOR ALL FIREBOXES: PHZC32C, PHZC36C, PHZC42C or PHZCI28LP, PHZCI28NG,
PHZCI32LP, PHZCI32NG:
7. To use the blower, plug it in. If you've installed a single pole switch, ip the switch to turn
it on. If you don't have the switch, as soon as it is plugged in, it will begin to blow.
8. To shut off the blower, ip the switch to off. Or, if you don't have a switch, unplug the unit.

8
MAINTENANCE OF MOTORS
Always disconnect the appliance from the main power supply and allow it to cool
before any servicing operation. The motor used on the blower is pre-lubricated
for extended bearing life and requires no further lubrication. However, periodic
cleaning/vacuuming of the appliance around the air intake and exhaust, as well
as the blower is recommended. For heavy or continuous use, periodic cleaning
must be done more frequently. If the heater blows alternating cold and warm
air, check the blower for free movement and for debris restricting air ow. If the
blower does not move freely, the unit must be turned off and the blower replaced
immediately in order to prevent further damage to the unit.
WARNING: Make sure all power to the appliance is turned OFF
before proceeding.
Printed in China
Troubleshooting
PROBLEM POSSIBLE CAUSE CORRECTIVE ACTION
Blower is not
spinning.
Blower is
making a loud
noise.
1. There is no power to
the blower.
2. Blower motor is bad.
1. Blower housing or
blades are dirty.
2. Blower rotation is
blocked.
3. Defective blower.
1. Clean blower and blower
housing.
2. Verify wiring is not in blower
path.
3. Replace blower.
1. Remove and change "Replace
blower" to #1.
2. Replace blower.
This product includes a warranty against any defect in materials and
workmanship for a period of one (1) year from the date of retail sale. Contact our
Consumer Warranty Dept. for more information (800) 776-9425.

9
MAINTENANCE OF MOTORS
Printed in China
33
blower
blower
blowers
blower
This limited warranty is extended to the original retail purchaser of this blower and warrants against any
1
1
one
one
years
years
TO REGISTER THE WARRANTY ON YOUR BLOWER, PLEASE FILL OUT THE CARD COMPLETELY
OR REGISTER ONLINE AT www.ghpgroupinc.com
blower

10
34
GHP Group, Inc.
6440 W Howard St
Niles, IL 60714-3302
Tel: (877) 447-4768
www.ghpgroupinc.com
GHP Group, Inc.
6440 W Howard St
Niles, IL 60714-3302
Autres manuels pour ZCB100