PICOTE Sentinel Guard 2.0 Mode d’emploi

I
N
S
T
R
U
C
T
I
O
N
S
Operating & Safety Manual
Sentinel Guard 2.0
These instrucons are for your personal safety. Always ensure that
you have read and understood these instrucons before using the
machinery. SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE.
We now have resellers in the U.S., Europe & Australasia.
Locate your reseller at picotesolutions.com

2
TOPIC PAGE/S
SAFETY INFORMATION & SYMBOLS 3
OVERVIEW 5
FEATURES 6
FUNCTIONS & USAGE 8
CHANGING SETTINGS & SMS COMMANDS 9
MAINTENANCE & SPARE PARTS 11
WARRANTY POLICY & PROCEDURE 12
To watch practical demonstration videos, or to download an electronic copy of these In-
structions, please visit www.picotesolutions.com. Please note that videos are not intend-
ed as a replacement or alternative to this operating and safety manual, but only as an
additional learning tool.
TABLE OF CONTENTS

3
SAFETY INFORMATION
This section contains important safety information. Failure to
comply could result in serious injury or death.
Safety Symbols
Safety symbols are used throughout this manual to draw attention to potential hazards.
Personal Protective Equipment (PPE)
Always use Personal Protective Equipment which is needed on a working site where the
Sentinel Guard 2.0 is being deployed.
Danger risk of serious injury, follow instructions.
SAVE ALL WARNINGS AND INSTRUCTIONS FOR FUTURE REFERENCE
TRANSPORT
Sennel Guard 2.0should be transported in car or other vehicle secured so that any sudden movements caused by hard
braking or accident are prevented. Always tranport Sennel inside the vehicle.
STORAGE
Sennel Guard 2.0 should be strored under cover in condensaon frost free environment. It is recemmended that Sen-
nel units are stored indoors protected from rain and sunlight and in and constant ambient temperature.
If Sennel will be stored in colder environment than +10 oC (50 oF ), the machine should be stood at room temperature
for 24hours before use.
DISPOSAL
Sennel Guard 2.0 can be disposed in Europe at Waste Electrical and Electronic Equipment (WEEE) collecon points.
Always follow the local waste handling rules and regulaon.
ENVIRONMENTAL
Operaonal Ambient Temperature Range: -10...50 oC (14...122 oF) frost and condensaon free
Storage Ambient Temperature Range: -20...60 oC (-4...140 oF) frost and condensaon free
Maximum Humidity: 95% non-condensing

4
Always read all safety warnings and instrucons. Failure to follow warnings and instrucons may result in electric
shock, re and/or serious injury.
GENERAL MACHINE SAFETY WARNING
SAVE ALL WARNINGS AND INSTRUCTIONS FOR FUTURE REFERENCE
SAFETY REQUIREMENTS
1. Always follow the instrucons in the Picote Soluons manual.
2. Before each use inspect the Sennel Guard 2.0 carefully for any potenal break or damage. Change damaged
sensors immediately.
3. When in use, it is very important that the Sennel Guard 2.0 is stable and on an even surface at all mes.
4. Do not open the lid of the Sennel Guard aer the SIM card has been placed inside.
5. If the working environment is extremely hot and humid, or badly polluted by conducve dust, use a GFCI-enabled
power outlet to ensure the safety of the operator.
6. Always check the internet connecon quality prior to use the Sennel Guard 2.0.
7. Only use the Sennel Guard 2.0 with the accessories and spare parts oered by Picote Soluons. Accessories and
spare parts should only be used in the manner intended and as described by Picote Soluons.
This secon contains important safety informaon. Failure to comply could result in serious injury or death.
This secon contains important safety informaon. Failure to comply could result in serious injury or death.

5
TECHNICAL DATA
Size
(mm/inches)
Air Pressure connectors Power
Supply Monitoring
Weight
(kg/lbs)
IP Rang
287x205x180
11”x8”x7”
2
110-230V / 50-60Hz
400V / 50-60Hz
5.8 / 12.8 67 sealed closed
INTENDED USE
This machine is intended for the following uses;
1. Monitoring pressure of the linings.
2. Monitoring power supply.
3. Monitoring water level in pumping staons.
4. Monitoring temperature.
Sennel 2.0 has a built in remote alarm feature. This allows it to send an alert message to a mobile phone
in cases of power outage, uctuaon of the pressure outside the limits or water level in a pumping staon
rise too high. The alerts will be sent by calling, text messages via the GSM network and email. User can
also check the situaon in working site in-me by logging on website hps://phoenix.onos..
GENERAL INFORMATION

6
SIM CARD
Ensure that the supply voltage is correct. The voltage of the power source must match the value given on the name-
plate of the machine within the tolerances of ±10 %. Machines with a 230V plate can be used in 220V mains and
110V machines in the 120V grid.
The machine has been double sealed according to European standards. The power source has to be grounded.
To begin using the Sennel 2.0 device, connect it to a mains power socket using the provided cable.
Always connect the power supply provided to the Sennel 2.0 unit. The unit has a back-up baery as well, but it is
only intended as a back-up for pressure measurement and to send alarm messages in the event of power failure, and
is NOT a substute for the mains power supply.
VOLTAGE & POWER SUPPLY
Sennel Guard uses a Mini sized SIM card. The SIM card slot is found under the lid. Once the SIM card has been in-
serted inside, the lid should be closed at all mes. Before inserng the SIM card into the Sennel Guard 2.0, the PIN
code lock must be turned o. This can be done by inserng the SIM card into a mobile phone and turning the PIN
code lock o.
It is recommended to use subscripon based SIM cards and not prepaid SIM cards. Prepaid SIM cards might run out
of credit or be closed down inconspicuously.
Step 1. Open Sennel Guard 2.0 lid.
Step 2. Turn the SIM card PIN code lock o with your mobile phone.
NOTE! Sennel Guard 2.0 uses Mini sized SIM card. Use adapter to make your SIM card larger if needed.

7
CONNECTORS
There are three dierent types of connectors in the Sennel Guard 2.0 device: pressure, water, and power. The pres-
sure connectors and water sensor connector are located on the le side of the Sennel 2.0 unit. The power supply
connector is located on the right side of Sennel unit.
When connecng the power supply connector or the water sensor connector, push the connector to the socket, and
screw the threaded nut all the way in. The power and water sensor connectors have a groove and cannot be connec-
ted if misaligned. The power and water sensor connectors have protecve covers that are meant to be used when
the connector is not in use.
START UP
To begin using the Sennel Guard 2.0 device, connect it to a mains power socket using the provided cable.
Always connect the power supply provided to the Sennel Guard 2.0unit. The unit has a back-up baery as well,
but it is only intended as a back-up for pressure measurement and to send alarm messages in the event of power
failure, and is NOT a substute for the mains power supply.
Step 3. Push the SIM card into the slot as shown below. Check that SIM card is properly locked into
the slot. Close the lid and test that you can connect to your Sennel Guard 2.0 unit in hps://
phoenix.onos..

8
STEP 1. Open a web browser on your computer and go to hps://phoenix.onos.
LOGGIN INTO THE SENTINEL 2.0
STEP 2. Insert the username and password that were provided with the device.
STEP 3. Click on the Home buon.
STEP 4. Click on the Phoenix you want to control.
STEP 5. You will now see the main view of your Sennel Guard 2.0.

9
STEP 1. Log into your Sennel Guard 2.0 as per secon Logging into the Phoenix.
STEP 2. In the boom le corner you will nd a panel tled ADD ALERT ADDRESS.
STEP 3. To add a phone number, insert the phone number with the country code.
STEP 4. Aer typing phone number, click ADD. To add an email address, insert the email address.
STEP 5. Verify that the alert addresses are now listed in the ALERT ADDRESSES panel above.

10
STEP 1. Log into your Sennel Guard 2.0 as per secon Logging into the Phoenix.
STEP 2. In the boom le corner you will nd a panel tled REMOVE ALERT ADDRESS.
STEP 3. To remove a phone number, insert the phone number with the country code.
STEP 4. To remove an email address, insert the email address.
STEP 5. Verify that the alert address you removed is no longer listed in the ALERT ADDRESSES panel.
Ce manuel convient aux modèles suivants
4
Table des matières
Manuels Système de sécurité populaires d'autres marques

EDM
EDM Solution 6+6 Wireless-AE Manuel utilisateur

Highway Safety Group
Highway Safety Group EA401 Manuel utilisateur

Siren
Siren LED GSM Manuel utilisateur

Detection Systems
Detection Systems 7090i Instructions de montage

Se-Kure Controls
Se-Kure Controls MicroMini SK-4841 Manuel utilisateur

Siemens
Siemens FDM273 Manuel utilisateur