Phymetrix POA200 Manuel utilisateur

I
Read this manual before using the analyzer. For personal and system
safety, and for optimum product performance, make sure you
thoroughly understand the contents before installing, using, or
maintaining this analyzer.
Please visit our website www.phymetrix.ca for other products that
may be applicable to your needs. Every effort has been made to ensure
accuracy in the contents of this manual. Should there be any doubts to
the accuracy of the content please contact the manufacturer. The
contents of this manual are subject to change without notice.
The instructions, procedures, drawings, specifications and concepts
contained in this manual are the property of Phymetrix Ltd., and shall
not be used as the basis for the manufacture or sale of apparatus or
services, or reproduced or copied or transmitted in any form or by any
means without written permission.

II
Warranty
While the Phymetrix’s instrument has no problem in materials and
workmanship, the manufacturer shall have the right to make the
decision to repair or replace the analyzer. The battery is not within the
scope of this quality assurance. This warranty is effective from the
date of delivery to the original purchaser. If Phymetrix determines that
the equipment was defective, the warranty period is:
• one year from delivery for electronic or mechanical failures
If Phymetrix determines that the equipment was damaged by misuse,
improper installation, the use of unauthorized replacement parts, or
operating conditions outside the guidelines specified, the repairs are
not covered under this warranty.
Normal wear and tear, parts damaged by abuse, misuse, negligence or
accidents are specifically excluded from the warranty. Purchaser
acknowledges that in accepting and using this analyzer,
notwithstanding any contrary term or provision in the purchaser's
purchase order or otherwise, the only warranty extended by Phymetrix

III
is the express warranty contained herein. Purchaser further
acknowledges that there are no other warranties expressed or implied,
including without limitation, the warranty of merchantability or fitness
for a particular purpose; that there are no warranties which extend
beyond the description of the face hereof; that no oral warranties,
representations, or guarantees of any kind have been made by
Phymetrix, its distributors or the agents of either of them, that in any
way alter the terms of this warranty; that Phymetrix and its
distributors shall in no event be liable for any consequential or
incidental damages, including but not limited to injury to the person or
property of the purchaser or others, and from other losses or expenses
incurred by the purchaser arising from the use, operation, storage or
maintenance of the product covered by the warranty; that Phymetrix’s
liability under this warranty is restricted to repair or replacement of
defective parts at Phymetrix sole option; and that Phymetrix neither
assumes nor authorizes any other person to assume for it any other
warranty. The warranty shall be void if serial numbers affixed to the
products are removed, obliterated or defaced.

IV
Return Policy / Procedures
If equipment malfunction is suspected or it is determined that the
analyzer needs recalibration, please contact York Instrument, who is
Phymetrix’s general agent in China.
Communicate the instrument model number, serial number,
application including oxygen concentration range being measured, and
the details of the problem.
If the analyzer needs factory service you will be issued a RMA and
shipping instructions.
The factory will diagnose the equipment and upon determining the
problem will notify you whether the terms of the warranty cover the
required repair. If the costs are not covered you will need to approve
the estimated cost in order to proceed with the repair.

I
Contents
1 Introduction..................................................................................1
1.1 Panel description......................................................................... 5
1.2 Introduction of displays ..............................................................8
1.3 Function ....................................................................................13
1.4 Calibration.................................................................................13
2 Specifications...............................................................................17
3 Instrument instructions.................................................................18
3.1 Instructions.................................................................................18
3.2 Using the analyzer.....................................................................19
3.3 Powering up the analyzer..........................................................20
3.4 Ranging.....................................................................................21
3.5 Calibration.................................................................................22
3.6 Valves........................................................................................ 23
3.7 Sensor life .............................................................................24
3.8 Sample Line Connection........................................................... 25
3.9 Date storage ..............................................................................26
3.10 Battery charging and discharging............................................27

II
3.11 Safety…………………………………………………..……. 27
4 Calibration Troubleshooting………………………….………….28
5 Maintenance&Sensor Replacement.............................................30
6 Troubleshooting........................................................................... 33
7 Safety of the analyzer ................................................................. 36
8 Safety of sensor............................................................................38
9 Glossary of Terms........................................................................ 42

1
1 Introduction
POA200 portable oxygen analyzer can capture single data points and
also can monitor data continuously, and applicabl in all occasions
when an accurate oxygen concentration measurement is required. It is
widely used in many different sectors of the economy. Such as
combustion efficiency analysis , gas blending, breathing apparatus,
compost monitoring and food storage monitoring, etc.
Standard equipment includes:
POA 200 Portable Analyzer
Stainless Steel Quick Disconnect Fittings
Power Adapter
Manual
A Shoulder Strap
Carrying Case

2
Options:
Stainless steel sleeve
FPT pipe
Printer function
Software
Warning: DO NOT turn on the "bypass/sample
gas " valve before there is low concentration oxygen flow
to the analyzer. In other words: Never expose the oxygen
sensor to the air, this will greatly reduce the life of the
sensor, or even damage the oxygen sensor!

3
Analyzer performance characteristics:
POA200 oxygen analyzer adopts a special weak acidity
electrochemical sensor. In its measuring range the sensor is linear
and therefore, measuring oxygen concentration is very stable
with a very wide measuring range: 0-10ppm and 0-10000ppm.
The resolution for the high quality LCD screen has a 320 * 240
color high-definition screen, and also shows the oxygen density,
maximum and minimum values, the total time of measurement,
the time difference, measurement process curve, the power and
the current time. Furthermore, it can also display the
measurement process curve, which will provide a clear and
reliable process analysis data for the users.
Automatic temperature compensation is corrected for the full
range, making the instruments more adaptable to harsh
environments..
A variety of measurement settings, users can choose one
appropiate to their needs.
It can switch interface in between English and Chinese according

4
to the users’ needs.
The analyzer is small and portable, making it comfortable to
service multiple locations on site.
Table des matières
Manuels Instrument analytique populaires d'autres marques

EXTOL PREMIUM
EXTOL PREMIUM 8820043 Instructions d'installation et d'utilisation

RIDGID
RIDGID SeeSnake Compact Manuel utilisateur

Teledyne
Teledyne 3000PA Manuel utilisateur

YDLIDAR
YDLIDAR TIA Manuel utilisateur

Olympus
Olympus IPLEX FX Series Manuel utilisateur

Bosch
Bosch GLM 50 C Professional Manuel utilisateur