LIMITED WARRANTY
PHASON warrants this unit, the SEC-HD, subject to the following terms and conditions. This warranty is valid only to the original purchaser for
a period of 2 years from the date of manufacturing. Manufacturing date is stated in the first eight digits of the serial number in the form year-
month-day. PHASON hereby warrants that should this product prove defective by reason of improper workmanship, PHASON will repair the
unit, effecting all necessary parts replacements without charge for either parts or labour.
CONDITIONS
1. Installation must be made in accordance with our enclosed installation instructions.
2. The unit must not have been previously altered, modified or repaired by anyone other than PHASON.
3. The unit must not have been subject to accident, misuse, abuse or operated or installed contrary to the instructions contained in
the accompanying manual. The opinion of PHASON with respect to these matters shall be final.
4. The person requesting the services provided hereunder must be the original purchaser of the unit and furnish proof of purchase
upon request.
5. This warranty is applicable only to the PHASON SEC-HD Temperature Control.
6. All transportation charges on units submitted for warranty repair must be borne by the purchaser.
7. For warranty services, return unit together with original proof of purchase to your dealer.
EXCEPT TO THE EXTENT PROHIBITED BY APPLICABLE LAW, NO OTHER WARRANTIES, WHETHER EXPRESSED
OR IMPLIED, INCLUDING WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE,
SHALL APPLY TO THIS UNIT. ANY AND ALL IMPLIED WARRANTIES ARE EXCLUDED. PHASON SHALL NOT BE
LIABLE FOR CONSEQUENTIAL DAMAGES SUSTAINED IN CONNECTION WITH THE SAID UNIT. PHASON NEITHER
ASSUMES NOR AUTHORIZES ANY REPRESENTATIVES OR OTHER PERSONS TO ASSUME FOR IT ANY
OBLIGATION OR LIABILITY OTHER THAN SUCH AS IS EXPRESSLY SET FORTH HEREIN.
PHASON RESERVES THE RIGHT TO IMPROVE OR ALTER THE SEC-HD WITHOUT NOTICE.
SERVICE AND TECHNICAL ASSISTANCE
Your dealer will be happy to answer all technical questions which will improve your use of the control. Be prepared
with the model number, serial number and necessary information before you place a call to your dealer. If your
control requires service when the warranty period has expired, return the unit to your dealer.

iii

iv
TABLE OF CONTENTS
FEATURES OF THE SEC-HD ........................................................................................................................ 1
GETTING STARTED...................................................................................................................................... 2
SEC-HD Electrical Ratings .................................................................................................. 4
Equipment List ..................................................................................................................... 5
GETTING TO KNOW THE SEC-HD ............................................................................................................. 6
Definition of Terms.............................................................................................................. 7
ADJUSTING THE SEC-HD ............................................................................................................................ 8
Selecting a new Operating Program ..................................................................................... 8
Changing Parameter Settings................................................................................................ 9
Setup Parameters.................................................................................................................. 11
Programming Tips................................................................................................................11
Reloading the Factory Settings............................................................................................. 13
SEC-HD OPERATION .................................................................................................................................... 14
Parameter Descriptions ........................................................................................................ 16
Parameter Ranges................................................................................................................. 19
Factory Programs ................................................................................................................. 20
METHODS OF USE ........................................................................................................................................ 21
ALARM MESSAGES ...................................................................................................................................... 22
Reasons for Alarms to Activate............................................................................................ 22
CARE AND MAINTENANCE ........................................................................................................................ 24
POWER FACTOR CORRECTION ................................................................................................................. 25
APPENDIX A - Wiring Diagrams.................................................................................................................... 26
APPENDIX B - Self-test Procedure ................................................................................................................. 39
APPENDIX C - Trouble Shooting Guide ......................................................................................................... 43
APPENDIX D - Blank Program Tables............................................................................................................ 46

SEC-HD User Manual 2001-01-23
102452 Rev. 2 1
FEATURES OF THE SEC-HD
The Staged Environment Control (SEC-HD), is a microprocessor based product designed to efficiently control the
environment in livestock buildings. It connects to two variable speed fans, a combination of secondary fans and heaters and
an alarm system. When operating, the SEC-HD measures and displays the room temperature. While monitoring the
temperature it controls the connected ventilation and heating equipment according to the programmed settings to keep the
temperature at the desired point. The program settings can be adjusted to change the turn on points and other parameters of
the stages. This is a list of the standard features of the SEC-HD.
•Digital display of temperature, alarms and settings
•7 programs with pre-programmed factory settings which can be easily changed
•A built-in keyboard to allow easy adjustment of settings
•3 stages with relay contacts to control secondary fans or heaters
•A relay to signal high or low temperature, power interruptions or low line voltage conditions
•Internal memory is retained during power failures
•115/230 VAC operation @ 10.0 full load amps output for each variable speed fan (with noise suppression to
eliminate radio and T.V. interference)
•Three second full power turn on for variable speed outputs to minimize fan freeze-up
•Transient protected
•Compact design, 18cm/7" (H) x 23cm/9" (W) x 9.5cm/3.75" (D)
•Non-corrosive, fire retardant enclosure
•Two year warranty
•Sensor can be extended

SEC-HD User Manual 2001-01-23
102452 Rev. 2 2
GETTING STARTED
Congratulations on the purchase of your new SEC-HD environment control! This manual has been prepared to help you get
the utmost in satisfaction from your SEC-HD. It contains detailed information regarding the installation and operation of the
control. The Getting Started section will step you through the installation and configuration of your SEC-HD. The following
steps refer to other sections of this user's guide for additional information. For this reason, it is not necessary to read through
the entire document from front to back, but rather in the order that the information is needed.
CHECKING RATINGS OF EQUIPMENT
STEP 1•Read the SEC-HD ELECTRICAL RATINGS on page 4.
•Fill in the EQUIPMENT LIST on page 5.
WARNING: The equipment to be connected to the SEC-HD control must not draw more
current than what the SEC-HD stages are rated for. Use of equipment that is rated
higher than the SEC-HD will result in damage to the control and will void the warranty.
INSTALLATION
STEP 2•Follow the instructions in Appendix A for installing and wiring the SEC-HD
and equipment. Be sure to read the General Warnings section in Appendix A
before installation.
TESTING
STEP 3•Turn to Appendix B and follow the instructions there, to test the operation of
the equipment installed to ensure that it is connected properly.

SEC-HD User Manual 2001-01-23
102452 Rev. 2 3
SETTING UP
STEP 4
•Read through the GETTING TO KNOW THE SEC-HD section on page 6 and
get familiar with the programming procedures.
•Read the SETUP section on page 11.
•Configure the SEC-HD according to the type of equipment connected.
•Mark the changes in the Blank Program Tables in Appendix D.
PUTTING CONTROL INTO SERVICE
STEP 5•Read the SEC-HD OPERATION section on page 14.
•Select the most useful factory program, see page 20.
•Make changes to the program as desired, see page 9.
•Mark the changes in the Blank Program Tables in Appendix D.
METHODS OF USE
STEP 6•Read the METHODS OF USE section on page 21.

SEC-HD User Manual 2001-01-23
102452 Rev. 2 4
SEC-HD Electrical Ratings
TEMP SENSOR
Standard sensor: 30
feet
ALARM RELAY RATINGS:
0.2 Amps, 230 VAC
0.4 Amps, 24 VAC
2 Amps, 30 VDC for
resistive loads
STAGES 3, 4 and 5 MAXIMUM RATINGS:
6 FLA (full load amps) each
115 or 230 VAC
VARIABLE SPEED STAGES
MAXIMUM RATINGS:
10.0 FLA (full load amps) each
115 or 230 VAC
NOTE: This is not a wiring diagram. All wiring diagrams are located in Appendix A.

SEC-HD User Manual 2001-01-23
102452 Rev. 2 5
Equipment List
Make and Model # of fan(s):
Max. Total Current Draw of fan(s):
Must not be greater than 10.0 amps.
Variable
Speed
Stage 1
Operating Voltage:
Make and Model # of fan(s):
Max. Total Current Draw of fan(s):
Must not be greater than 10.0 amps.
Variable
Speed
Stage 2
Operating Voltage:
Make and Model # of fan/heater:
Max. Total Current Draw:
Operating Voltage:
Cool / Heat
Stage 3
Make and Model # of fan/heater:
Max. Total Current Draw:
Operating Voltage:
Cool / Heat
Stage 4
Make and Model # of fan/heater:
Max. Total Current Draw:
Operating Voltage:
Cool / Heat
Stage 5
Alarm relay connected to:
Alarm
* A power contactor must be used if the maximum total current draw is greater than the maximum ratings of the relay. See the
maximum ratings on page 4.
Table des matières
Autres manuels Phason Contrôleurs

Phason
Phason Natural Ventilation Control Manuel utilisateur

Phason
Phason PEC Manuel utilisateur

Phason
Phason NVC-2-12 Manuel utilisateur

Phason
Phason PLUS Series Manuel utilisateur

Phason
Phason FC Series Manuel utilisateur

Phason
Phason TVS Manuel utilisateur

Phason
Phason MSC-4 Manuel utilisateur

Phason
Phason FHC-1D Manuel utilisateur