Pfeiffer TPG 36 Series Manuel utilisateur

EN
INSTALLATION INSTRUCTIONS
ISTRUZIONI PER L’INSTALLAZIONE
INSTRUCCIONES DE INSTALACIÓN
INSTALLATIE-INSTRUCTIES
INSTALLATIONSINSTRUKTIONER
安装手册
설치지침
PG 0034 BXX/B (1512)
IT
ES
NL
SV
ZH
KO
SUPPLEMENTARY INFORMATION
TPG 36X
Controller, Centralina, Unidad de control, Bedieningsapparaat, Styrenhet

2
EN
EN
Range of application
The units TPG 361 respectively TPG 362 must be installed and operated in the following
ambient conditions:
Installation, Setup The unit can be operated in three different ways:
– mounted in a 19" rack cabinet
– mounted in an operator panel
– as a desktop unit
Rack installation The unit is designed for installation into a 19" rack chassis adapter according to DIN 41
494. For this purpose, four collar screws and plastic sleeves are supplied with it.
Installation location weather protected (indoor)
Protection class IP 20
Installation altitude max. 2000 m
Ambient temperature +5°C to +50°C
Relative humidity 5 ... 85 %, non-condensing
Atmospheric pressure 860 hPa - 1060 hPa
DANGER
Commissioning of a defective product
Putting a product which presents a visible damage into operation can be extremely haz-
ardous.
If the product presents a visible damage do not put it into operation and make sure it
is not inadvertently put into operation.
NOTICE
Loss of the protection class of the rack
If the product is installed in a rack, it is likely to lower the protection class of the rack
(protection against foreign bodies and water) e.g. according to the EN 60204-1 regula-
tions for switching cabinets.
Take appropriate measures for the rack to meet the specifications of the protection
class.
NOTICE
Thermal overload!
Set up the unit so that the admissible maximum ambient temperature (e. g. due to
installation or sunlight) is not exceeded.
Ensure adequate air circulation!

EN
3
Guide rail
Fig. 1: Mounting the TPG 36x into the rack frame using a rack chassis adapter
In order to reduce the mechanical strain on the front panel of the TPG 36x, preferably
equip the rack chassis adapter with a guide rail.
Secure the rack adapter in the rack frame.
Slide the TPG 36x into the rack chassis adapter and fasten the adapter panel to the
rack chassis adapter using the screws supplied with the TPG 36x.
Installation in a Con-
trol Panel
1
2 3
NOTICE
Loss of the protection class of the rack
If the product is installed in a rack, it is likely to lower the protection class of the rack
(protection against foreign bodies and water) e.g. according to the EN 60204-1 regula-
tions for switching cabinets.
Take appropriate measures for the rack to meet the specifications of the protection
class.
NOTICE
Thermal overload!
Set up the unit so that the admissible maximum ambient temperature (e. g. due to
installation or sunlight) is not exceeded.
Ensure adequate air circulation!

4
EN
Fig. 2: For mounting the unit into a control panel, this cut-out is required
Fig. 3: Installing the TPG 36x in a control cabinet
Slide the TPG 36x into the cut-out of the control panel and secure it with four M3 or
equivalent screws.
– For reducing the mechanical strain on the front panel, preferably support the unit.
Desk-Top Unit The TPG 36x is also suited for use as desk-top unit. For this purpose, two self-adhesive
rubber feet as well as a slip-on rubber bar are supplied with it.
M3 oder ø3.5
122.5
113
70
55.9
NOTICE
Thermal overload!
Set up the unit so that the admissible maximum ambient temperature (e. g. due to
installation or sunlight) is not exceeded.
Ensure adequate air circulation!

EN
5
Stick the two supplied rubber feet to the rear part of the bottom plate.
Slip the supplied rubber bar onto the bottom edge of the front panel.
Connecting to the mains power supply
The TPG 36x is equipped with an universal power supply with an input voltage range of
100 ... 240 V AC.
Fig. 4: Mains cable with protective earth conductor
Switch off switch S1 on the power pack (position "0").
CAUTION
Excess voltage!
Danger of destroying the unit.
Power connections must comply with local regulations. Voltage information given on
the rating plate must correspond to the mains voltage values.
Use only cable with protective earth conductor.
To protect the electronics and the power supply cable in case of failure provide an
appropriate network safety device.
WARNING
Danger of electric shock
In case of defect, the parts connected to the mains supply are under voltage.
Always keep the mains connection freely accessible so you can disconnect it at any
time.
S1
10 Amax

6
EN
Connect the mains cable to the mains.
Always ensure a safe connection to the protective earthing conductor (PE, protection
class I).
To protect the unit in case of malfunction, carry out fuse protection in accordance with
the regional regulations.
– Select a fuse with slow characteristics.
If the unit is installed in a rack, the mains voltage must be supplied via a switched power
distributor.
Earthing On the rear side there is a screw to connect the TPG 36x via a protective ground if nec-
essary, for example, with the protective earthing of the pumping station.
Fig. 5: Protective ground
Connections For each measurement channel, there is a female appliance connector on the rear of the
unit. At the TPG 361 the gauge connection sensor 2 does not exist.
Connect the gauge to the sensor connector via a sensor cable set available from the
supplier or your own, screened (electromagnetic compatibility) sensor cable. Use
compatible gauges only.
6-pin C91B appliance con-
nector
Connection "control"This connector allows to read the measuring signal, to evaluate the state of the floating
contacts of the error relay, and to activate or deactivate the gauges.
Connect the peripheral components to the control connector on the rear of the unit us-
ing your own, screened (electromagnetic compatibility) cable.
– A suitable connector is supplied with the TPG 36x.
X: Do not unfasten this screw
(internal ground protection)
X
5
2
36
4
1
Pin Signal
1 Identification
6 Supply (+24 V DC)
2 Supply common (GND)
3 Signal input (0 ... +10 V DC)
4 Signal common
5 Screening

EN
7
7-pin C91B appliance con-
nector
Table 1: At the TPG 361 Pin 1 and Pin 6 are not used
Relay output
This connector allows to use the floating switching contacts for an external control sys-
tem.
Pin assignment of the fe-
male 15-pin D-Sub appli-
ance connector:
Table 2: At the TPG 361 Pin 9 and Pin 14 are not used
RS-485 The RS-485 interface allows operation of the TPG 36x via a computer or a terminal. The
use of a Y-connector allows integration into a bus system.
Connect the serial interface to the RS-485 connector on the rear of the unit using a
shielded cable (electromagnetic compatibility).
5
2
7
3
6
4
1
Pin Signal
2 Analog output gauge 1 (0 ... 10 V DC)
1 Analog output gauge 2 (0 ... 10 V DC)
5 Screening GND
4 Gauge 1 on: signal ≤+ 0.8 V DC
off: signal +2.0 ... 5 V DC or input open
6 Gauge 2 on: signal ≤+ 0.8 V DC
off: signal +2.0 ... 5 V DC or input open
3-7 No error
3-7 Error or power supply turned off
NOTICE
Damage to the product
Only connect cables when de-energized.
Never establish a connection using a live cable.
15 9
81
Pin Signal
4
3
2
Switching function 1
Pressure below threshold Pressure above threshold or power supply turned off
7
6
5
Switching function 2
Pressure below threshold Pressure above threshold or power supply turned off
11
10
9
Switching function 3
Pressure below threshold Pressure above threshold or power supply turned off
14
13
12
Switching function 4
Pressure below threshold Pressure above threshold or power supply turned off
Pin Supply for relays with higher switching power
15
1
8
+24 V DC, 200 mA
GND
GND
Fuse-protected at 300 mA with PTC element, self-reset-
ting after power off or pulling the relay connector. Meets
the requirements of a grounded protective extra low volt-
age (SELV).

8
EN
5-pin M12 female appli-
ance connector
USB connection B-type USB
The B-type USB port facilitates direct communication with the TPG 36x via a computer
(e.g. firmware update, parameter storage (read/write)).
B-type USB
Connect a USB port with a shielded cable (electromagnetic compatibility) to the USB
terminal on the back of the device.
A-type USB
The A-type USB port, which has master functionality, is located on the front and is used
for the connection of a USB memory stick (for instance, for firmware updates, parameter
storage (read/write), data logger).
A-type USB
Connect the USB memory stick to the USB port on the front of the device.
Ethernet The Ethernet port supports direct communication with the TPG 36x via a computer.
●Green LED: Link or transmit LED.
– Indicates that a hardware-based connection exists.
●Yellow LED: Status or packet-detect LED.
– Indicates the status of the transmission. Whenever this LED flashes or flickers, this
indicates that data is being transmitted.
8-pin RJ45
Connect the Ethernet cable to the port on the back of the device.
12
34
5
Pin Assignment
1 RS-485: D+
2+24V
3GND
4 RS-485: D-
5 not connected
ChassisChassis
RXD
TXD
GND
2
3
5
RXD
TXD
GND
z.B. PC TPG 26x, TPG 36x
(Minimalkonfiguration/Minimal configuration)
4 3
1 2
Pin Assignment
1 VBUS (+5 V)
2D-
3D+
4GND
1 2 3 4
Pin Assignment
1 VBUS (+5 V)
2D-
3D+
4GND
8 1
Pin Assignment
1 TD+ (transmitted data +)
2 TD- (transmitted data -)
3 RD+ (received data +)
4NC
5NC
6 RD- (received data -)
7NC
8NC

IT
9
IT
Campo di impiego Gli strumenti TPG 361 ovvero TPG 362 devono essere installati e azionati rispettando le
seguenti condizioni ambientali:
Montaggio, installazione
Lo strumento può funzionare in tre diversi modi:
– montato in un armadio rack da 19"
– montato in un quadro di comando
– come strumento da tavolo
Montaggio nel rack Lo strumento è destinato al montaggio in un adattatore a inserimento per rack da 19" a
norma DIN 41494. A tal fine, in dotazione ci sono quattro viti a colletto e un nipplo di pla-
stica.
Luogo di installazione protezione contro agenti atmosferici (locali interni)
Grado di protezione IP 20
Altitudine di installazione max. 2,000 m
Temperatura ambiente +5 °C fino a +50 °C
Umidità dell’aria rel. 5 ... 85 %, senza condensa
Pressione atmosferica 860 hPa - 1060 hPa
PERICOLO
Messa in funzione di un prodotto difettoso
In caso di danneggiamenti palesi, mettere in funzione il prodotto potrebbe comportare
conseguenze letali.
Non mettere in funzione il prodotto e bloccarlo per impedirne l'avviamento acciden-
tale.
AVVISO
Perdita del grado di protezione dello strumento
Lo strumento montato è in grado di neutralizzare il grado di protezione necessario (pro-
tezione da corpi estranei e acqua) ad es. di quadri elettrici a norma EN 60204-1.
Occorre pertanto ripristinare il grado di protezione necessario a mezzo di idonee mi-
sure.
AVVISO
Sovraccarico termico!
Installare lo strumento in modo tale che la temperatura ambientale massima ammes-
sa per il dispositivo (ad es. conseguente al montaggio o alle radiazioni solari) non
venga superata.
Garantire la circolazione dell'aria!

10
IT
Guida
Fig. 6: TPG 36x montare nell'armadio rack mediante l'adattatore a inserimento rack
Per non sovraccaricare il pannello frontale del TPG 36x si consiglia di munire l'adat-
tatore a inserimento rack di una guida.
Fissare l'adattatore a inserimento rack nell'armadio rack.
TPG 36x inserire nell'adattatore a inserimento rack e fissare con le viti in dotazione.
Montaggionelquadro
di comando
Fig. 7: Per il montaggio in un quadro di comando è necessaria quest'apertura d'incastro del
quadro
1
2 3
AVVISO
Perdita del grado di protezione dello strumento
Lo strumento montato è in grado di neutralizzare il grado di protezione necessario (pro-
tezione da corpi estranei e acqua) ad es. di quadri elettrici a norma EN 60204-1.
Occorre pertanto ripristinare il grado di protezione necessario a mezzo di idonee mi-
sure.
AVVISO
Sovraccarico termico!
Installare lo strumento in modo tale che la temperatura ambientale massima ammes-
sa per il dispositivo (ad es. conseguente al montaggio o alle radiazioni solari) non
venga superata.
Garantire la circolazione dell'aria!
M3 oder ø3.5
122.5
113
70
55.9
Ce manuel convient aux modèles suivants
2
Table des matières
Langues :
Autres manuels Pfeiffer Contrôleurs