Perin WeighMaster 800 Mode d’emploi

WEIGHT INDICATOR
Model 800
USER’S HANDBOOK
english
PERIN
WeighMaster
Perin WeighMaster s.r.l.
via Paolo Borsellino, 15
26845 Codogno (LO) - ITALY
Tel. +39 0377 437033 - Fax 437046
www.farmscale.com
email: [email protected]

INDEX
page
Safety regulations for system installation and maintenance................................3
Maintenance.............................................................................................................3
Disposal of the device..............................................................................................3
Description of the device........................................................................................4
onnections............................................................................................................4
Battery test..................................................................................................................4
Function of keys.......................................................................................................5
Messages and icons on display................................................................................5
Use as simple weight indicator............................................................................6
Zeroing (tare)...................................................................................................6
Partial weighings..................................................................................................6
Use with quick alarm.....................................................................................6
Selection of functions...........................................................................................6
Programming recipes.... ..........................................................................................7
Programming loading in total values....................................................................7
Loading ration N° 1 (total values)........................................................................8
Programming per number of animals...................................................................9
Loading ration N° 2 (number of animals)............................................................11
Programming unloading groups........................................................................11
Unloading ration N° 3 (groups)..........................................................................12
Extra functions................................................................................................13
HOLD function (weight freeze)....................................................................13
Programmed weight restore function................................................................13
Selection of the component............................................................................13
Selection automatic/manual passage...............................................................13
Ingredients Reproportion....................................................................................13
Storage function......................................................................................................14
Troubles and solutions.............................................................................................14
System representation.............................................................................................15
Technical details...................................................................................................15
onfiguration starting parameters...........................................................................16
Warranty..........................................................................................................17
Accessories on demand...........................................................................................18
Declaration of onformity...................................................................................19

The producer
PERIN WEIGHMASTER SRL
Viale A. Moro 7
26845 odogno (LO)
declares that the below-mentioned equipment is in accordance with the essential
requirements of the applicable regulations:
1 Electromagnetic ompatibility Directive EM 2004/108/ E (ex 89/336/ EE)
and Legislative Decree N. 194/2007.
Applied harmonized law:
- EI EN 61326
odogno, 02 February 2015
The technical head
Fabio Perin
Denomination Weighing System
800Model
CE Declaration of conformity

MAINTENANCE
FarmScale mod. 800 does not require any regular maintenance, however it is necessary to
check the conditions of the weighing system periodically.
1) Make sure that there are no disturbing elements between the supporting chassis and the
platform or the container, the basin, the feeder, etc.
2) Make sure that the load cells are not damaged (no cracks nor dents), not rusty, not corroded
by acids.
3) Make sure that there is enough space between the chassis and the components of the
weighing system; lubricate if necessary.
4) Make a test: load a weight on each corner, the displayed amount must be nearly the same.
5) Make sure that the connectors are tight and that the cables are undamaged (no cuts nor
abrasions). Remember that, where food is stored or handled, small rodents often gnaw
cables which are situated in hidden or scarcely reachable places.
6) heck that there is no oxidation nor humidity on the connecting points.
7) Do not install the device near heat sources (radiators/oil tanks). Do not fix it on surfaces
with strong vibrations.
DISPOSAL OF THE DEVICE
SAFETY REGULATIONS FOR SYSTEM INSTALLATION AND MAINTENANCE
- Install only when power supply is disconnected.
- Do not install the device near heat sources or near strong magnetic fields.
- Disconnect the power supply cable from the weight indicator when you need to recharge the
battery of the means of transport.
- Immediately disconnect the power supply cable if the cables or the connectors are stripped
or damaged, if the system has particular problems or if there is liquid/humidity in the device.
- The tension should stay between 12V and 14V to avoid damaging the other parts of the
system. The device works correctly with tensions between 10V and 24V.
- Before cleaning the machine with high pressure waterjets, disconnect the cables, remove the
weight indicator from the machine and protect the connectors of the cables from water seepage.
Pay attention that the load cells, the junction box, the alarm and other accessories are not
exposed to direct waterjets.
If the device needs to be cleaned, use soft and lightly humid cloths.
Do not use sprays, solvents, abrasives, sharp or cutting objects which could damage the case.
- Do not open the device, to avoid losing the warranty right. For maintenance/reparation, address
to our company or to technical authorized staff.
- Before doing any welding on the machine, disconnect the cables.
To prevent welding current from passing through load cells, it is necessary to shortcircuit the
body of the load cells with a cable with adequate section and the earth of the welder must be
connected near the point where you weld.
This symbol, present on the product or on the handbook, indicates that the product
cannot be thrown together with household garbage (European Directive 2012/19/EU).
The final user has to dispose of the device at a gathering place for recycling and
disposal of electrical and electronical devices. The separate refuse collection and
the correct recycling of the devices allow to protect the health of people and
ecosystem. For further information concerning gathering points for devices, contact
the local authority for the disposal of garbage or the distributor where the product
has been purchased.

Indicator mod. 800
4
DESCRIPTION OF THE DEVICE
indicators of recipe
and ingredient n°
6 operative keys
load cells connector
power supply
connector -
alarm output
weight value
and messages
on/off switch
BATTERY TEST
The battery test should be made periodically (entering voltage level to FarmScale mod. 800).
To carry out this test, when you are in total weight mode, keep the key pressed;
"volts" with the voltage value of power supply will be displayed and the alarm will sound
intermittently. Press once again to have the direct weight reading.
function
indicators
starbus
connector for
remote display
(optional)
CONNECTIONS
The device has got three connectors. From left to right: a 5 pin connector for the connection
of the extension cable (LOAD ELLS), an optional 7 pin connector for the connection of
remote displays (STARBUS), a 3 pin connector for the connection of the power supply and
alarm cable (POWER).
Before making connections, make sure that the device and the possible peripherals are off.
Before introducing any connector, make sure it is the right one and then connect it adequately,
otherwise damages to the device could occur.
After having introduced the connector, screw the fixing ring.
To disconnect the cables from the plugs, rotate the upper ring anticlockwise, keeping the
lower ring steady. Pull out the connector. Do not pull the cable directly.

Indicator mod. 800 5
Kept pressed, it carries out
the battery test with
intermittent alarm
Stores the value of an
ingredient and displays the
following ingredient
Scrolls the ingredients of
the recipe
Freezes the weight value Increases the value of the
digit
Holds the weight value
Passes from total to net and
viceversa (stores the value,
recalls the total weight).
Kept pressed, it zeroes the
scale (tare)
Zeroes the wrong values;
kept pressed, it goes back
to direct reading
Restores the value of a
programmed ingredient;
kept pressed, it goes back
to direct reading
Selects the functions of
rations recall, programming
and storage
Stores the digit and passes
to the next one
Selects manual or
automatic passage to the
following ingredient
Allows to set the alarm
individual value for
loading/unloading.
Presents the earlier
programmed alarm values
Recalls previous
ingredient/recipe
Recalls previous
ingredient/recipe
Pressing this key lightly, the device switches on; keeping it pressed, it switches off
MESSAGES AND ICONS ON DISPLAY
HEllo
HoLd
out
The device is switching on
(it shows the version of the
software)
Too low battery level Frozen value
Damaged alarm output
Battery voltage
Out of range low
Out of range high Storage cancellation
+
Signals alarm output Unit of measure
FUNCTION OF THE KEYS
DIRECT READING PROGRAMMING EXECUTING RECIPES
Or-H
Or-L
cLr
volts 12.5
Kg/lb

Indicator mod. 800
6
USE AS SIMPLE WEIGHT INDICATOR
Switch the indicator on with the key and wait for a few seconds. After the HELLO
message, the indicator shows the model and the version and prepares itself for direct reading.
(In case of interruption of the ration execution, the device could switch off; the indicator would
then switch on again showing the loadings to be completed). Load and you will immediately
read the value corresponding to the loaded weight.
NB: in the beginning it might be necessary to adjust the zero, because the mechanical parts
of the system need some time to settle.
ZEROING (TARE)
Switch the indicator on, after a few seconds a value will be displayed. Keep the key
pressed until the display shows the message tArE. The indicator goes automatically to zero.
PARTIAL WEIGHINGS
To make loading of different ingredients easier, without using the alarm, press .
The display will visualize "0" with an indicator which will set on NET. Load the ingredient,
press again and the indicator will move to TOTAL so that the total loaded weight will
be shown. Follow this procedure for all the partial weighings (loading and unloading).
SELECTION OF FUNCTIONS
To pass from a function to another one you only need to press the key .
The fixed indicator will move every time to indicate the selected function:
TOTAL / EXE UT / PROGRAM / A UM.
USE WITH QUICK ALARM (SET/RECALL)
FarmScale mod. 800 gives the possibility to set loading/unloading values with alarm (you
do not need to programme recipes). To set a value, press the key and use the keys
to increase the digits and to select the digits. In the end press to
confirm the value. Proceed with loading or unloading.
Load; the value on the display will decrease in proportion to the loaded amount.
When 85% of the load has been reached, you will hear an intermittent signal: load
with care. When 100% has been reached, you will hear a continuous signal: stop
loading immediately.
In this mode the weight indicator stores the individual weighings which can be recalled by
pressing repeatedly the key .
While setting the value to program, keeping the key or pressed,
you can pass to the setting mode with direct increase/decrease of the displayed value.
!

Indicator mod. 800 7
PROGRAMMING RATIONS
FarmScale Mod. 800 has a memory able to store programmes of 20 recipes of 20 ingredients
each, which can be used for loading and unloading.
When executing the ration, the indicator automatically recognizes if a loading or unloading
is being carried out (LOAD/UNLO announcers); there will be an alarm both for loading and
for unloading. It is therefore possible to use the programming of recipes to manage different
unloading groups, too.
There are two different ways of setting the programming:
- in total values (the ingredients are expressed in total kilos)
- proportional to the number of animals (the ingredients are expressed per animal)
The user should prepare a list of all the ingredients with their values in order to program the
recipe in a correct way.
PROGRAMMING LOADING IN TOTAL VALUES
The ingredients are introduced in total Kg. After the ration has been entered, before executing
it, it is still possible to change the total value with automatic adaptation of components.
e.g. - program the recipe n. 1 composed of the following ingredients: n. 1 of 110 kg, n. 2 of
225 kg and n. 3 of 1120 kg. Proceed in this way: switch on the indicator and wait for a few
seconds.
PRESS
it confirms that you want to program recipe n. 1.
OWS and the number of animals are displayed.
The first digit on the right blinks
it confirms the number of animals is zero (the
programming is in total values) and displays
INGR with ingredient n. 1
it stores the first digit (units) and moves to the
second one
it increases the second digit (tens)
it stores the second digit
it increases the third digit (hundreds)
it stores the value of ingredient n. 1
and displays the value of ingredient n. 2
it increases the value of the first digit (units)
it stores the first digit
press it twice; the indicator sets on PROGRAM with the
recipe n. 1 and the total of the recipe
1
10000
1
10000
1
10010
1
10010
1
10110
1
20000
1
20005
1
20005
DISPLAY
1
recipe
ingredient
0000

Indicator mod. 800
8
it stores the value of the ingredient n. 3
Press it several times. It allows to scroll the other values,
up to the 20th ingredient, and displays the total of the recipe
To leave the PROGRAM function, press .
LOADING Ration n° 1 (total values)
PRESS
it displays the loading function (EXE UT)
and the total of the first recipe
it confirms the loading function. The digit on
the right blinks to indicate that it is possible to
change the total of the ration with automatic adaptation
of the ingredients
DISPLAY
Load ration n. 1 whose total is 1455 Kg
While setting the value to be programmed, keeping the key or pressed,
you can pass to the setting mode with direct increase/decrease of the displayed value.
it increases the value of the second digit (tens)
it stores the second digit
it increases the value of the third digit (hundreds)
it stores the value of ingredient n. 2
and displays the value of ingredient n. 3
it stores the first digit (units)
it increases the value of the second digit (tens)
it stores the second digit
it increases the value of the third digit (hundreds)
it stores the third digit
1
20225
1
30000
1
30020
1
30020
1
30120
1
30120
1
20025
1
20025
1
30000
11455
11455
11455

Indicator mod. 800 9
PROGRAMMING PER NUMBER OF ANIMALS
e.g. - program recipe n. 2 for 123 animals with ingredient n. 1 of 1,10 kg, n. 2 of 2,25 kg, n.
3 of 9,20 kg.
The full stop (.) indicates that the values are expressed per animal.
Proceed as follow: switch the indicator on
press it twice for the program function; PROGRAM will
be displayed. The total of the recipe n. 1 will be displayed
it increases the number of the recipe
it confirms the recipe n. 2; it asks for the number
of animals OWS (the right digit blinks)
it increases the first digit (units)
it stores the first digit and displays the second one
it increases the second digit (tens)
it stores the second digit
it increases the third digit (hundreds)
it stores the number of animals and displays
the value of the ingredient n. 1
it stores the first digit (dag)
2
100.00
2
100.00
PRESS DISPLAY
it confirms the execution of the ration n. 1 and
displays the ingredient n. 1 ready for loading.
The announcers LOAD and AUTO are activated
1
1110
Load; the value on the display will decrease in proportion to the loaded amount.
When 85% of the load has been reached, you will hear an intermittent signal: load
with care. When 100% has been reached, you will hear a continuous signal: stop
loading immediately.
After 5 seconds, the alarm stops and the value of the ingredient n. 2 (ready to be loaded)
will appear on the display. Proceed ...
After loading all the ingredients, the total weight will be displayed.
1 0
20000
20003
20023
20023
20123
20
!
20003
Table des matières