Pepperl+Fuchs VISUNET GMP DM Manuel utilisateur

VISUNET GMP DM
DIRECT MONITOR
HARDWARE MANUAL
PROCESS AUTOMATION
MANUAL

With regard to the supply of products, the current issue of the following document is ap-
plicable: The General Terms of Delivery for Products and Services of the Electrical In-
dustry, published by the Central Association of the Electrical Industry (Zentralverband
Elektrotechnik und Elektroindustrie (ZVEI) e.V.) in its most recent version as well as the
supplementary clause: "Expanded reservation of proprietorship"
VISUNET GMP DM

VISUNET GMP DM
Contents
3
1 Safety................................................................................................. 4
1.1 Validity ....................................................................................................................................4
1.2 Symbols used ........................................................................................................................4
1.3 System Operator and Personnel ..........................................................................................5
1.4 Pertinent Laws, Standards, Directives and further Documentation .................................5
1.5 Intended use...........................................................................................................................5
1.6 Installation and commissioning ...........................................................................................5
2 Product Specifications .................................................................... 6
2.1 Overview.................................................................................................................................6
2.2 Technical Data .......................................................................................................................8
2.3 Dimensions ............................................................................................................................9
2.4 Interfaces and connectionsVisuNet GMP DM .....................................................................9
2.5 Accessories.......................................................................................................................... 11
2.5.1 Pedestals ............................................................................................................................... 11
2.5.2 Wall mounting ........................................................................................................................12
2.5.3 Hole drilling templates ...........................................................................................................13
2.5.4 Power supply accessories .....................................................................................................14
3 Installation and Commissioning................................................... 15
3.1 Preparation...........................................................................................................................15
3.2 Mounting in the field............................................................................................................15
3.3 Commissioning VisuNet GMP RM/PC................................................................................16
4 Operation ........................................................................................ 17
4.1 On Screen Display ...............................................................................................................17
4.1.1 Audio menu...........................................................................................................................19
4.1.2 Bright-Contrast menu ..........................................................................................................20
4.1.3 Color menu ...........................................................................................................................21
4.1.4 Image menu ..........................................................................................................................22
4.1.5 Tools menu ...........................................................................................................................23
4.1.6 Input menu ............................................................................................................................24
4.1.7 Exit menu ..............................................................................................................................25
5 Appendix......................................................................................... 26
5.1 How to contact Pepperl+Fuchs GmbH ..............................................................................26

219365 2006-06
4
VISUNET GMP DM
Safety
1Safety
1.1 Validity
The chapter “Safety”is valid as operating instructions.
Specific process and instructions in this document require special precautions to guarantee
the safety of personnel.
1.2 Symbols used
This document contains information that you must read for your own personal safety and to
avoid property damage. The warning signs are displayed in descending order depending
on the hazard category, as follows:
Safety-relevant symbols
Informative symbols
Action
This symbol marks an acting paragraph.
Danger!
This symbol indicates a warning about a possible danger.
In the event the warning is ignored, the consequences may range from personal injury to
death.
Warning!
This symbol indicates a warning about a possible fault or danger.
In the event the warning is ignored, the consequences may course personal injury or
heaviest property damage.
Caution!
This symbol warns of a possible fault.
Failure to observe the instructions given in this warning may result in the devices and any
connected facilities or systems develop a fault or fail completely.
Note!
This symbol brings important information to your attention.

VISUNET GMP DM
Safety
219365 2006-06
5
1.3 System Operator and Personnel
The operator of the system is responsible in terms of planning, mounting, commissioning,
operating and maintenance.
Assembly, commissioning, operation, maintenance and dismounting of any devices may
only be carried out by trained, qualified personnel who have read and understood the
instruction manual.
1.4 Pertinent Laws, Standards, Directives and further Documentation
Laws, standards, or directives applicable to the intended use must be observed. In relation
to explosive areas, Directive 94/9 EC must be observed.
The corresponding data sheets, the declaration of conformity, the EC-type-examination
certificate and applicable certificates (see data sheet) are an integral part of this document.
1.5 Intended use
The devices are only approved for appropriate and intended use. Ignoring these
instructions will invalidate any warranty and absolve the manufacturer from any liability.
1.6 Installation and commissioning
The device must only be operated in the ambient temperature range and at the relative
humidity (noncondensing) specified.
To connect interfaces only use shielded cable.
To advance the cable shield screw/lock the connectors.
Lead data cable and power circuit line in separate cable channels.
Before commissioning the system check all cables and connectors.

219365 2006-06
6
VISUNET GMP DM
Product Specifications
2 Product Specifications
2.1 Overview
GMP (“Good Manufacturing Practice”) is a set of guidelines for assuring the quality of
production processes in controlledindustries and closely follow the guidelines issued by the
European Commission or the FDA in the US. GMP applications are typically used in the
pharmaceutical and food industries. However, products that conform with GMP guidelines
are also required for the manufacture of cosmetics and fragrances or fl avors.
The materials selected, design of the surfaces and architecture of the overall system
should prevent the accumulation of fl uids and dirt. Cleaning, maintenance, inspection and
servicing must be as safe and easy as the processes employed for the disinfection,
pasteurization and sterilization of mechanical components. The VisuNet GMP product
portfolio extends from simple direct monitors and remote monitor systems with Ethernet
connection to a host, to complete PCs available with single or dual monitor systems and
various mounting options. All models feature a 19-inch display with an optional touch
screen. The stainless steel housings have an IP65 degree of protection. Remote monitors
and PCs are equipped with RS232, PS/2, Ethernet and USB interfaces.
The VisuNet GMP product family guarantees a perfect fit for every system infrastructure.
Four models are available depending on the functions required, the display and input unit
and the distance over which the data is transferred. This manual describes the VisuNet
GMP Direct Monitor (DM):

VISUNET GMP DM
Product Specifications
219365 2006-06
7
VisuNet GMP DM are direct monitors, which are directly connected to the VGA interface of
the host. Industrial keyboards with integral mouse connected directly to the host are
available as accessories.
Overview of features
• The brilliant display provides high meter-reading comfort
• Easy, user-friendly handling due to optionally available touch screen
• Image position, pixel frequency and phase will be detected and synchronized
automatically
• Rugged stainless steel housing
• Degree of protection IP65
max. 15 m
DM
HOST

219365 2006-06
8
VISUNET GMP DM
Product Specifications
2.2 Technical Data
VisuNet GMP DM
General specifications
Type Direct monitor
Supply
Power supply 20 ... 30 V DC
Power consumption 40 W
Indicators/operating means
Display
Type TFT, LCD, High Color (19 bit)
Screen diagonal 19 ''
Resolution 1280 x 1024 Pixel
Representable colors 16,7 Mio.
Brightness 300 cd/m2
Input devices Analog resistive touchscreen (optional) ,
Input device combined with keyboard and optional
trackball/touch screen/joystick
Interface
Interface type VGA
Ambient conditions
Ambient temperature 0 ... 50 °C
Mechanical specifications
Protection degree IP65
Installation panel mounting
several mounting devices (rotatable/fix) available
Mass 18 kg
Dimensions 568 mm x 450 mm x 65 mm

VISUNET GMP DM
Product Specifications
219365 2006-06
9
2.3 Dimensions
Figure 2.1: VisuNet GMP model with inclinable keyboard (90°-180°)
2.4 Interfaces and connectionsVisuNet GMP DM
The interfaces and connections of the VisuNet GMP are located within the VESA adapter
at the back of the housing.
The following interfaces are available:
Figure 2.2: VESA adapter at the back of the VisuNet GMP housing
9
10
9
10
228.5
378
39.5
567.8
450
65
235
559 40
Agrounding bolt
BPhoenix DFK-MSTB 2,5/ 4-GF-5,08
CVGA interface
B
C
1
4
A
1
6
515
11

219365 2006-06
10
VISUNET GMP DM
Product Specifications
Power supply
4-pin socket for power supply connecting (Phoenix Contact DFK-MSTB 2,5/ 4-GF-5,08).
Matching plug: Phoenix Contact MSTBT 2,5/ 4-STF-5,08
VGA interface
15-pin HD-D-Sub socket "VGA" for connecting the monitor to the host.
Picture Pin Signal
1 -
2 -
3 +
4 +
Picture Pin Signal Pin Signal Pin Signal
1RED 6RED_GND 11 not used
2GREEN 7GREEN_GND 12 IIC-DATA
3BLUE 8BLUE_GND 13 HSYNC
4not used 9+ 5 V 14 VSYNC
5GND 10 GND 15 IIC-CLOCK
41
1
6
5
15 11
Table des matières
Autres manuels Pepperl+Fuchs Moniteur

Pepperl+Fuchs
Pepperl+Fuchs VisuNet IND DM5 Series Manuel utilisateur

Pepperl+Fuchs
Pepperl+Fuchs VisuNet GXP Series Guide de l'utilisateur

Pepperl+Fuchs
Pepperl+Fuchs VisuNet GXP RM-GXP1100-22F Manuel utilisateur

Pepperl+Fuchs
Pepperl+Fuchs VisuNet DPU2100 Series Manuel utilisateur

Pepperl+Fuchs
Pepperl+Fuchs VisuNet GMP DM200 Series Manuel utilisateur

Pepperl+Fuchs
Pepperl+Fuchs DPU1100-J1 Series Manuel utilisateur

Pepperl+Fuchs
Pepperl+Fuchs VisuNet GXP Series Manuel utilisateur

Pepperl+Fuchs
Pepperl+Fuchs VBA-2E2A-KE4-ENC/SSI-S Manuel utilisateur

Pepperl+Fuchs
Pepperl+Fuchs DA6-SSI/A-U Manuel utilisateur

Pepperl+Fuchs
Pepperl+Fuchs KFD2-SR2-Ex2.W.SM Manuel utilisateur