Pentair Pool Products Fleck SXT Manuel utilisateur

SXT Timer
Supplemental Service Manual
IMPORTANT: Fill in Pertinent Information on Page 3 for Future Reference

Job Specication Sheet......................................................................................................................................... 3
Timer Features ...................................................................................................................................................... 4
Timer Operation..................................................................................................................................................... 6
Master Programming Mode Chart ......................................................................................................................... 8
Master Programming Mode................................................................................................................................. 10
User Programming Mode .................................................................................................................................... 17
Diagnostic Programming Mode ........................................................................................................................... 19
2510 / 2750 / 2850s Timer Assembly .................................................................................................................. 21
9000 / 9100 / 9500 Twin Tank Timer Assembly ................................................................................................... 22
3/4" Plastic Turbine Meter Assembly ................................................................................................................... 23
Meter Assembly ................................................................................................................................................... 24
3/4" Brass Paddle Meter Assembly ..................................................................................................................... 25
1" Brass Paddle Meter Assembly ........................................................................................................................ 26
Inline Plastic Turbine Meter Assembly................................................................................................................. 27
1-1/2" Brass Paddle Meter Assembly .................................................................................................................. 28
3/4", 1" or 1-1/2" Paddle Wheel Meter Cap Assembly......................................................................................... 29
2510SXT Wiring Diagram.................................................................................................................................... 30
2750SXT / 2850SXT Wiring Diagram.................................................................................................................. 31
9000SXT / 9100SXT / 9500SXT Wiring Diagram................................................................................................ 32
Troubleshooting................................................................................................................................................... 33
Service Assemblies ............................................................................................................................................. 34
Table of Contents
IMPORTANT PLEASE READ:
• The information, specications and illustrations in this manual are based on the latest information available at the time of
printing. The manufacturer reserves the right to make changes at any time without notice.
• This manual is intended as a guide for service of the valve only. System installation requires information from a number of
suppliers not known at the time of manufacture. This product should be installed by a plumbing professional.
• This unit is designed to be installed on potable water systems only.
• This product must be installed in compliance with all state and municipal plumbing and electrical codes. Permits may be
required at the time of installation.
• If daytime operating pressure exceeds 80 psi (5.5 bar), nighttime pressures may exceed pressure limits. A pressure reducing
valve must be installed.
• Do not install the unit where temperatures may drop below 32°F (0°C) or above 110°F (43°C).
• Do not place the unit in direct sunlight. Black units will absorb radiant heat increasing internal temperatures.
• Do not strike the valve or any of the components.
• Warranty of this product extends to manufacturing defects. Misapplication of this product may result in failure to properly
condition water, or damage to product.
• A prelter should be used on installations in which free solids are present.
• In some applications local municipalities treat water with Chloramines. High Chloramine levels may damage valve components.
• Correct and constant voltage must be supplied to the control valve to maintain proper function.

Job Number: __________________
Model Number: ________________
Water Hardness: ___________________ ppm or gpg
Capacity Per Unit: ______________
Mineral Tank Size: ___________ Diameter: ___________ Height:
Salt Setting per Regeneration: _____________________________________________
1. Type of Timer:
A. 7 Day or 12 Day B. Meter Initiated
2. Downow: Upow UpowVariable
3. Meter Size:
A. 3/4” Std Range (125 - 2,100 gallon setting)
B. 3/4” Ext Range (625 - 10,625 gallon setting)
C. 1” Std Range (310 - 5,270 gallon setting)
D. 1” Ext Range (1,150 - 26,350 gallon setting)
E. 1-1/2” Std Range (625 - 10,625 gallon setting)
F. 1-1/2” Ext Range (3,125 - 53,125 gallon setting)
G. 2” Std Range (1,250 - 21,250 gallon setting)
H. 2” Ext Range (6,250 - 106,250 gallon setting)
I. 3” Std Range (3,750 - 63,750 gallon setting)
J. 3” Ext Range (18,750 - 318,750 gallon setting)
K. Electronic________ Pulse Count ________ Meter Size
4. System Type:
A. System #4: 1 Tank, 1 Meter, Immediate, or Delayed Regeneration
B. System #4: Time Clock
C. System #4: Twin Tank
D. System #5: 2-5 Tanks, 2 Meters, Interlock
E. System #6: 2-5 Tanks, 1 Meter, Series Regeneration
F. System #7: 2-5 Tanks, 1 Meter, Alternating
G. System #9: Electronic Only, 2-4 Tanks, Meter per Valve, Alternating
H. System #14: Electronic Only, 2-4 Tanks, Meter per Valve. Brings units on and ofine based on ow.
5. Timer Program Settings:
A. Backwash: ______________________ Minutes
B. Brine and Slow Rinse: _____________ Minutes
C. Rapid Rinse: ____________________ Minutes
D. Brine Tank Rell: _________________ Minutes
E. Pause Time: ____________________ Minutes
F. Second Backwash: _______________ Minutes
6. Drain Line Flow Control: ____________ gpm
7. Brine Line Flow Controller: __________________ gpm
8. Injector Size#: _____________________
9. Piston Type:
A. Hard Water Bypass
B. No Hard Water Bypass
Job Specication Sheet

Page 4
Timer Features
Features of the SXT:
• Power backup that continues to keep time and the passage of days for a minimum of 48 hours in the event of
power failure. During a power outage, the control goes into a power-saving mode. It does not monitor water
usage during a power failure, but it does store the volume remaining at the time of power failure.
• Settings for both valve (basic system) and control type (method used to trigger a regeneration).
• Day-of-the-Week controls.
• While in service, the display alternates between time of day, volume remaining or days to regeneration, and
tank in service (twin tank systems only).
• The Flow Indicator ashes when outlet ow is detected.
• The Service Icon ashes if a regeneration cycle has been queued.
• A Regeneration can be triggered immediately by pressing the Extra Cycle button for ve seconds.
• The Parameter Display displays the current Cycle Step (BW, BF, RR, etc) during regeneration, and the data
display counts down the time remaining for that cycle step. While the valve is transferring to a new cycle step,
the display will ash. The parameter display will identify the destination cycle step (BW, BF, RR, etc) and the
data display will read “----”. Once the valve reaches the cycle step, the display will stop ashing and the data
display will change to the time remaining. During regeneration, the user can force the control to advance to
the next cycle step immediately by pressing the extra cycle button.
Setting the Time of Day
1. Press and hold either the Up or Down buttons until the programming icon replaces the service icon and the
parameter display reads TD.
2. Adjust the displayed time with the Up and Down buttons.
3. When the desired time is set, press the Extra Cycle button to resume normal operation. The unit will also
return to normal operation after 5 seconds if no buttons are pressed.
Parameter
Display
Data
Display
PM
Indicator
Flow Indicator
x1000 Indicator
Service
Icon
Programming
Icon
Extra Cycle
Button
Up
Button
Down
Button
Error/
Information
Icon

Page 5
Timer Features
Queueing a Regeneration
1. Press the Extra Cycle button. The service icon will ash to indicate that a regeneration is queued.
2. To cancel a queued regeneration, press the Extra Cycle button.
Regenerating Immediately
Press and hold the Extra Cycle button for ve seconds.

Page 6
Timer Operation
Meter Immediate Control
A meter immediate control measures water usage and regenerates the system as soon as the calculated system
capacity is depleted. The control calculates the system capacity by dividing the unit capacity (typically expressed
in grains/unit volume) by the feedwater hardness and subtracting the reserve. Meter Immediate systems generally
do not use a reserve volume. However, in twin tank systems with soft-water regeneration, the reserve capacity
should be set to the volume of water used during regeneration to prevent hard water break-through. A Meter
Immediate control will also start a regeneration cycle at the programmed regeneration time if a number of days
equal to the regeneration day override pass before water usage depletes the calculated system capacity.
Meter Delayed Control
A Meter Delayed Control measures water usage and regenerates the system at the programmed regeneration
time after the calculated system capacity is depleted. As with Meter Immediate systems, the control calculates the
system capacity by dividing the unit capacity by the feedwater hardness and subtracting the reserve. The reserve
should be set to insure that the system delivers treated water between the time the system capacity is depleted
and the actual regeneration time. A Meter Delayed control will also start a regeneration cycle at the programmed
regeneration time if a number of days equal to the regeneration day override pass before water usage depletes
the calculated system capacity.
Time Clock Delayed Control
A Time Clock Delayed Control regenerates the system on a timed interval. The control will initiate a regeneration
cycle at the programmed regeneration time when the number of days since the last regeneration equals the
regeneration day override value.
Day of the Week Control
This control regenerates the system on a weekly schedule. The schedule is dened in Master Programming by
setting each day to either “off” or “on.” The control will initiates a regeneration cycle on days that have been set to
“on” at the specied regeneration time.
Control Operation During Regeneration
During regeneration, the control displays a special regeneration display. In this display, the control shows the
current regeneration step number the valve is advancing to, or has reached, and the time remaining in that step.
The step number that displays ashes until the valve completes driving to this regeneration step position. Once all
regeneration steps are complete the valve returns to service and resumes normal operation.
Pressing the Extra Cycle button during a regeneration cycle immediately advances the valve to the next cycle
step position and resumes normal step timing.
Control Operation During Programming
The control only enters the Program Mode with the valve in service. While in the Program Mode, the control
continues to operate normally monitoring water usage and keeping all displays up to date. Control programming is
stored in memory permanently, eliminating the need for battery backup power.
Manually Initiating a Regeneration
1. When timer is in service, press the Extra Cycle button for 5 seconds on the main screen.
2. The timer advances to Regeneration Cycle Step #1 (rapid rinse), and begins programmed time count down.
3. Press the Extra Cycle button once to advance valve to Regeneration Cycle Step #2 (backwash).
4. Press the Extra Cycle button once to advance valve to Regeneration Cycle Step #3 (brine draw & slow rinse).
5. Press the Extra Cycle button once to advance valve to Regeneration Cycle Step #4 (brine rell).
6. Press the Extra Cycle button once more to advance the valve back to in service.
NOTE: If the unit is a lter or upow, the cycle step order may change.
NOTE: A queued regeneration can be initiated by pressing the Extra Cycle button. To clear a queued
regeneration, press the Extra Cycle button again to cancel. If regeneration occurs for any reason prior to the
delayed regeneration time, the manual regeneration request shall be cleared.

Page 7
Timer Operation
Control Operation During A Power Failure
The SXT includes integral power backup. In the event of power failure, the control shifts into a power-saving
mode. The control stops monitoring water usage, and the display and motor shut down, but it continues to keep
track of the time and day for a minimum of 48 hours.
The system conguration settings are stored in a non-volatile memory and are stored indenitely with or without
line power. The Time of Day ashes when there has been a power failure. Press any button to stop the Time of
Day from ashing.
If power fails while the unit is in regeneration, the control will save the current valve position before it shuts down.
When power is restored, the control will resume the regeneration cycle from the point where power failed. Note
that if power fails during a regeneration cycle, the valve will remain in it’s current position until power is restored.
The valve system should include all required safety components to prevent overows resulting from a power
failure during regeneration.
The control will not start a new regeneration cycle without line power. If the valve misses a scheduled
regeneration due to a power failure, it will queue a regeneration. Once power is restored, the control will initiate
a regeneration cycle the next time that the Time of Day equals the programmed regeneration time. Typically,
this means that the valve will regenerate one day after it was originally scheduled. If the treated water output is
important and power interruptions are expected, the system should be setup with a sufcient reserve capacity to
compensate for regeneration delays.

Page 8
Master Programming Mode Chart
CAUTION:BeforeenteringMasterProgramming,pleasecontactyourlocalprofessionalwaterdealer.
Master Programming Options
Abbreviation Parameter Option
Abbreviation
Options
DF Display Format
GAL Gallons
Ltr Liters
Cu Cubic Meters
VT Valve Type
St1b Standard Downow/Upow Single Backwash
St2b Standard Downow/Upow Double Backwash
Fltr Filter
UFbF Upow Brine First
8500 TwinFlo100SXT
Othr Other
CT Control Type
Fd Meter (Flow) Delayed
FI Meter (Flow) Immediate
tc Time Clock
dAY Day of Week
NT Number of Tanks 1Single Tank System
2Two Tank System
TS Tank in Service
U1 Tank 1 in Service
U2 Tank 2 in Service
C Unit Capacity Unit Capacity (Grains)
HFeedwater
Hardness
Hardness of Inlet Water
RS Reserve Selection SF Percentage Safety Factor
rc Fixed Reserve Capacity
SF Safety Factor Percentage of the system capacity to be used as a
reserve
RC Fixed Reserve
Capacity
Fixed volume to be used as a reserve
DO Day Override The system’s day override setting
RT Regen Time The time of day the system will regenerate
BW, BD, RR,
BF
Regen Cycle Step
Times
The time duration for each regeneration step.
Adjustable from OFF and 0-199 minutes.
NOTE:If“Othr”ischosenunder“ValveType”,then
R1,R2,R3,etc,willbedisplayedinstead
D1, D2, D3, D4,
D5, D6, & D7
Day of Week
Settings
Regeneration setting (On or OFF) for each day of the
week on day-of-week systems

Page 9
Master Programming Mode Chart
CAUTION:BeforeenteringMasterProgramming,pleasecontactyourlocalprofessionalwaterdealer.
Master Programming Options
CD Current Day The Current day of the week
FM Flow Meter Type
t0.7 3/4" Turbine Meter
P0.7 3/4" Paddle Wheel Meter
t1.0 1" Turbine Meter
P1.0 1" Paddle Wheel Meter
t1.5 1.5" Turbine Meter
P1.5 1.5" Paddle Wheel Meter
Gen Generic or Other Meter
KMeter Pulse Setting Meter pulses per gallon for generic/other ow meter
NOTES:
Someitemsmaynotbeshowndependingontimerconguration.
ThetimerwilldiscardanychangesandexitMasterProgrammingModeifanybuttonisnotpressedfor
sixty seconds.

Page 10
Master Programming Mode
CAUTION:BeforeenteringMasterProgramming,pleasecontactyourlocalprofessionalwaterdealer.
When the Master Programming Mode is entered, all available option setting displays may be viewed and set as
needed. Depending on current option settings, some parameters cannot be viewed or set.
Setting the Time of Day
1. Press and hold either the Up or Down buttons until the programming icon replaces the service icon and the
parameter display reads TD.
2. Adjust the displayed time with the Up and Down buttons.
3. When the desired time is set, press the Extra Cycle button to resume normal operation. The unit will also
return to normal operation after 5 seconds if no buttons are pressed.
Entering Master Programming Mode
Set the Time Of Day display to 12:01 P.M. Press the Extra Cycle button (to exit Setting Time of Day mode). Then
press and hold the Up and Down buttons together until the programming icon replaces the service icon and the
Display Format screen appears.
Exiting Master Programming Mode
Press the Extra Cycle button to accept the displayed settings and cycle to the next parameter. Press the
Extra Cycle button at the last parameter to save all settings and return to normal operation. The control
will automatically disregard any programming changes and return to normal operation if it is left in Master
Programming mode for 5 minutes without any keypad input.
Resets:
Soft Reset: Press and hold the Extra Cycle and Down buttons for 25 seconds while in normal Service mode.
This resets all parameters to the system default values, except the volume remaining in meter immediate or meter
delayed systems and days since regeneration in the time clock system.
Master Reset: Hold the Extra Cycle button while powering up the unit. This resets all of the parameters in the
unit. Check and verify the choices selected in Master Programming Mode.
1. Display Format (Display Code DF)
This is the rst screen that appears when entering Master Programming Mode. The Display Format setting
species the unit of measure that will be used for volume and how the control will display the Time of Day. This
option setting is identied by “DF” in the upper left hand corner of the screen. There are three possible settings:
Display Format Setting UnitofVolume Time Display
GAL U.S. Gallons 12-Hour AM/PM
Ltr Liters 24-Hour
Cu Cubic Meters 24-Hour