PeakTech 1140 Manuel utilisateur

PeakTech®1140
Operation manual
Testsignal-Generator
DAB-Standard
ETS 300 401
PeakTech®1140
PeakTech®- Spitzentechnolo
g
ie, die überzeu
g
t

PeakTech®1140
Read First
In order for a long period of trouble-free service of the instrument, please pay
special attention to the following precautions:
1. Protect the instrument from excessive impact during transportation and
installation.
2. Be sure to verify whether the line voltage setting matches the line voltage
used.
3. Use a fuse with correct ratings only.
4. Do not apply excessive AC or DC voltage to the signal output connector
beyond the maximum voltage allowed.
5. Use the instrument within operating temperature range,
which is from 15 deg C to 35 deg C.
6. For an accurate measurement,
allow approximately 30 minutes of instrument warm-up time.
7. Avoid operating the instrument under the following conditions; direct sun light,
rapid temperature variation, high humidity, or strong magnetic field.
8. Do not alter or change the parts or their locations inside the instrument. please
contact PeakTech®company for service and calibration.
This Information contained in this document is subject to change without Notice

PeakTech®1140
Safety Notes
The following symbols on instrument and in the documentation indicate
precautions which must be taken to maintain safe operation of the instrument.
Warning
: A warning calls attention to a procedure, practice or the like which.
correctly performed or adhered to, could result in injury or loss of life.
Caution
: A Caution calls attention to a procedure, practice or the like which.
if not correctly performed or adhered to, could result in damage to
or the destruction of part or all of the equipment.
[ Safety Symbols ]
GROUND TERMINAL
PROTECTIVE CONDUCTOR
FRAME TERMINAL
CAUTION REFER TO ACCOMPANYING DOCUMENTS
ON (Supply)
OFF (Supply)

PeakTech®1140
Clearing and Maintenance
1. In order for a long period of trouble-free use of the instrument,
please read this manual carefully.
2. Be sure to verify whether the line voltage setting matches
the line voltage used. Use a fuse with the correct rating only.
3. Caution
Use 3 pin power cable to avoid any damage caused by floating voltage.
( but, Telephone analysers use 2 pin power cable)
4. Precaution
• Note :
If the equipment is used in a manner not specified by the
manufacturer,
the protection provided by the equipment may be impaired.
- Avoid placing this instrument in an extremely hot or cold place.
- Do not use this instrument after bring it in from the cold.
- Do not expose the instrument to wet or dusty environment.
- Do not place liquid-filled container,
such as coffee cups on top of this instrument
- Do not use this instrument where it is subject to serve vibration.
- Do not use this instrument in strong magnetic fields, such as near motors.
- Do not place heavy objects on the case or block the ventilation holes.
- Do not leave a hot soldering iron near the instrument.
- Cleaning :
To clean stained case, lightly rub the stained area with a soft cloth dipped
in a neutral detergent.
Never use highly volatile material such as benzene or paint thinner.

PeakTech®1140
CONTENTS
1. GENERAL
1.1 Description........................................................................................................................................ 1
1.2 General features ................................................................................................................................ 1
1.3 Specifications.................................................................................................................................... 1
2. INSTALLATION
2.1 Power Supply.................................................................................................................................... 3
2.2 Incoming confidence check .............................................................................................................. 3
3. OPERATING INSTRUCTIONS
3.1 Front panel controls .......................................................................................................................... 4
3.2 Rear panel controls ........................................................................................................................ 7
4. General Operation
4.1 Set_up ............................................................................................................................................... 8
4.2 Save / Recall ................................................................................................................................... 13
4.3 Select Group ................................................................................................................................... 14
4.4 Select Pattern .................................................................................................................................. 15
4.5 Select Mode .................................................................................................................................... 15
4.6 PRE_VIEW..................................................................................................................................... 16
4.7 Output On/Off................................................................................................................................. 17
4.8 Local On/Off................................................................................................................................... 17
5. RS-232c
5.1 RS-232C...........................................................................................................................18
5.2 RS-232C command List.......................................................................................................18
6. APPENDIX A:
A.1 Timing of I/Q Output ( Digital ) .................................................................................................... 20

PeakTech®1140
1
1. GENERAL
1.1 Description
The model PeakTech
®
1140 is a test signal generator complying with Some Digital Pattern Protocol
(European DAB Standard ETS 300 401) .
It is useful to verification of Audio Service and Data Service application of DAB / DMB receivers by
using DAB/DMB pattern.
1.2 General features
●Apply to Digital Pattern : 40 patterns * 4 Mode
█DAB-DMB ( Terrestrial ) : Current supply
● Save / Recall : 100 Patterns ( 00 ~ 99 )
● DAB-DMB ( T ) : Transmission Mode ( I, II, III , IV )
● Output Type : Continuous, Single , Repeat
● Interface
- IEEE 802.3u 100Base-TX , IEEE 802.3 10Base-T
- RS-232C standard.
● LCD Display
1.3 Specifications
. Compliant with the ETS 300 401 ( May 1997 )
. Transmission Mode : TI,TII,TIII,TIV
. DAB-DMB ( T) Pattern is sorted as follows
1st folder 2nd folder 3rd folder file
"Contents" "Group " "Pattern" "Play file "
. [ Example ]
1st folder 2nd folder 3rd folder file
"Contents" "Group " "Pattern" "Play file "
\1.DAB_DMB(T) \G01_Stream_Tone_data \P01_0_Tone&Data \G01P01T1.ply

PeakTech®1140
2
Sub
Channel
Bit Rate
(kbit/sec)
Protection
Level Code Rate
Size
( CU) contents
Audio Data
( L )
Audio Data
( R )
Start
Address PAD Type
1 UEP 256 4 0.57 168 stereo 1kHz 0 dB 1kHz 0 dB 0 VAR X-PAD
2 224 3 0.50 168 stereo 2kHz 0 dB 2kHz 0 dB 168
N
o-X-PAD
3 224 4 0.60 140 stereo 4kHz 0 dB 4kHz 0 dB 336 Short -Xpad
4 192 3 0.51 140 stereo 1kHz 0 dB mute 476 Short -Xpad
5 192 4 0.62 116 stereo mute 1kHz 0 dB 616
N
o-X-PAD
6 64 3 0.50 48 mono 1kHz 0 dB 1kHz 0 dB 732
N
o-X-PAD
7 EEP(8) 64 3 0.50 48 PRBS9 780
8 EEP(8) 24 2 0.38 24 PRBS9 828
…12 Padding 852
.I/Q Output
. Output Voltage : 1 Vpp
. Output Impedance : 50 Ω
.Digital I/Q
. Output Level : TTL
. Connector : D-sub 15 pin ( Female)
.Frame Synch Output : BNC-R ( TTL )
. Interface : LAN, RS-232C
. Power Requirements : 100 - 240VAC, 50/60Hz, 50VAmax
. Dimensions : 115(H) X 430(W) X 410(D)mm
.Weight (NetWeight) : Approx.8.2㎏( Except package box, Accessary...)
. Standard Accessories : Power Cable, BNC-BNC Cable ( 2ea ),
Operating Manual, Fuse
. Environmental Conditions : Indoor Use
Amplitude up to 2000m
Temperature 15°C to 35°C
Relative Humidity 50% to 80%
Cat II
Pollution degree 2

PeakTech®1140
3
2. INSTALLATION
2.1 Power Supply
This instrument requires a power source of 100V ~ 240V AC, 50 Hz / 60Hz. AC voltage is
automatically selected to proper input range. A 3P power cord as provided with instrument grounds the
instrument chassis when connected through the compatible power receptacle.
Do not use the unit if the safety ground is broken.
Fuse is 1 A (250V) at of 100V ~ 240V “ Time delay ” type.
2.2 Incoming confidence check
Prior to packaging the instrument for shipment, extensive operational, alignment, and calibration
procedure were performed by PeakTech
®
to verify that the instrument is operating to
specifications.
To ensure the electronic integrity of the instrument on your receiving bench, you must perform the
following confidence check:
As certain that the operating voltage, then connect the AC power cord to the mains.
Turn on power.
The display will be as follows ( System Booting )
Finally the display will be as follows
1st
G01:Stream_Tone_data
G02:Broadcasting Ex
G03:Stream_DMB
G04:Stream for BER (MSC) ↓
Warm up 1 minutes and connect the Up-Converter (PeakTech
®
1140)
Check the DAB/DMB receiver operating
This completes the incoming confidence check.
The instrument can now be placed in.

PeakTech®1140
4
3. OPERATING INSTRUCTIONS
3.1 Front panel controls
Figure 1.- Front panel.
1. LCD Display
Display the Ensemble contents or System states
2. Rotary Encoder
Increment or Decrement Display at Current Position
3. ENTER Key
It is used Terminal setting for next item
4. Set_Up Key:
Set the the Following Menu .
1) Contents : It is used to setting to 1st folder .
2) Output Type
3) Config.
4) System_info
5. Exit Key:
Use to return above Menu.

PeakTech®1140
5
6. Save Key:
It is used to store any files ( frequently using ) at some address ( 0 ~9 ) .
7. Recall Key:
It is used to recall some patterns from address( 0 ~ 9 ).
8. Group Key.
It is used to setting to 2nd folder.
Ex1) Contents = DAB/DMB ( T ) : T = Terrestrial
G01:Stream_Tone_data
G02:Broadcasting Ex
G03: Stream_DMB
G04:Stream for BER(MSC)
G05:Re_Configuration
G06:User define
G07:Test for production
9. Pattern Key
It is used to setting to 3rd folder .
Refer to Appendix A
The composition is updates without any notice
10. Mode ( Transmission Mode )
It is used to select Transmission Mode
1) TM1 ( TM I )
2) TM2 ( TM II )
3) TM3 ( TM III )
4) TM4 . ( TM IV )
Table des matières
Manuels Équipement d'enregistrement populaires d'autres marques

Strymon
Strymon NIGHTSKY Manuel utilisateur

Mitsubishi Electric
Mitsubishi Electric 16CH DIGITAL RECORDER DX-TL5000U Manuel utilisateur

Tews Technologies
Tews Technologies TPMC465 Manuel utilisateur

Honeywell
Honeywell Excel 50 Manuel utilisateur

SeaLevel
SeaLevel COMM+8.LPCI Manuel utilisateur

Arturia
Arturia AUDIOFUSE STUDIO Manuel utilisateur