Peak Genius 1025 Manuel utilisateur

Genius1025 User Manual Rev 6 RSID 2859 EN 15/11/21
Genius 1025
User Manual

Contents
Change History 3
How to use this Manual 3
Warranties and Liabilities 4
Safety Notices 5
Symbols 5
Safety Notice to Users 5
EU Declaration of Conformity 6
UK Declaration of Conformity 7
WEEE Compliance Statement 8
CSA Compliance Statement 9
Technical Specification 10
Genius 1025 10
Unpacking 11
Fittings Kit Contents 12
Installation 13
Generator Environment 13
Generator Overview 14
General Dimensions 14
Rear Connections 15
Unit Controls 15
Drain Connection 16
Electrical Connection 17
Start-Up Sequence 18
Connecting to the application 19
Tubing Lengths 19
Normal Operation 20
On Demand Gas 20
Generator Cycling 20
Unusual Operation 20
Service Requirements 21
Service Schedule 21
Service Indication 22
Stage 1 22
Stage 2 22
Service Indication Reset 22
Peak Protected 23
Cleaning 24
Troubleshooting 25
Page 2

Page 3
Change History
Rev Comment Name Date
1 Initial Release L. Couttie 31/01/2019
2 Updates to incorporate CSA feedback L. Couttie 07/10/2019
3 Updates to incorporate CSA feedback L. Couttie 21/10/2019
4 Technical Specification Update L. Couttie 27/02/2020
5 Water Bottle Info Added L. Couttie 20/03/2020
6 Declarations Update L. Couttie 15/11/2021
How to use this Manual
This manual is intended for end users and has been written as a reference document
where you can skip to the relevant information.
Users can refer to the contents page to find the relevant information.
Please review each of the following sections carefully.
Thank you for selecting Peak Scientific to meet your gas generation needs, and should
you require any further assistance or support please do not hesitate to contact Peak
Scientific or the Peak Partner from which you purchased your generator.

Page 4
Warranties and Liabilities
1. The Company warrants that it has title to the Goods.
2. Subject to the provisions of this clause the Company warrants that the Goods
shall comply in all material respects with any specification referred to in the Order
Confirmation (as the same may be amended) and shall, subject thereto, be free
from defects in material and workmanship for the lesser of a period of twelve
months from the date of delivery or thirteen months from the date of dispatch
from the factory.
3. Save as provided in this clause and except where the Goods are sold to a person
dealing as a consumer (within the meaning of the Unfair Contract Terms Act
1977) all warranties, conditions or other terms implied by statute or common
law are hereby expressly excluded save to the extent they may not be lawfully
excluded. When the Goods are sold to a consumer within the meaning of the Unfair
Contract Terms Act 1977 their statutory rights are not aected by the provisions of
this clause.
4. In the event of the Customer making a claim in respect of any defect in terms of
clause 2 hereof the Customer must.
1. Reasonably satisfy the Company that the Goods have been properly installed,
commissioned, stored, serviced and used and without prejudice to the generality
of the foregoing that any defect is not the direct or indirect result of lack of repair
and/or servicing, incorrect repair and/or servicing, use of wrong materials and/or
incorrect spare parts
2. Allow the company to inspect the Goods and/or any installation and any relevant
packaging as and when reasonably required by the Company.
5. Subject to the Company being notified of any defect as is referred to in sub-
clause 2 hereof within a reasonable time of it becoming apparent and subject always
to the terms of sub-clause 4 hereof, the Company shall, in its option, replace or
repair the defective Goods or refund a proportionate part of the Price. The Company
shall have no further liability to the Customer (save as mentioned in sub-clause 6
hereof).
6. The Company shall be liable to indemnify the Customer in respect of any claim
for death or personal injury to any person in so far as such is attributable to the
negligence or breach of duty of the Company or any failure by the Company to
comply with the provisions of sub-clause 2 hereof.
7. Save as provided in sub-clause 2 hereof the Company shall not be liable in respect
of any claim by the Customer for costs, damages, loss or expenses (whether direct,
indirect, consequential or otherwise) or indemnity in any respect howsoever arising
including, but not by way of limitation, liability arising in negligence (other than
pursuant to clause 6 above) that may be suered by the Customer or any third
party.

WARNING
WARNING
WARNING
WARNING
CAUTION
Page 5
Safety Notices
Peak Scientific Instruments cannot anticipate every possible circumstance which may
represent a potential hazard. The warnings detailed within this manual refer to the most
likely potential hazards, but by definition cannot be all inclusive. If the user employs
an operating procedure, item of equipment or a method of working which is not
specifically recommended by Peak Scientific, the user must ensure that the equipment
will not be damaged or become hazardous to persons or property.
Symbols
This manual uses the following symbols to highlight specific areas important to the safe
and proper use of the generator.
A WARNING notice denotes a hazard. It calls attention to an operating procedure,
process or similar, which if not correctly performed or adhered to, could cause
personal injury or in the worst case death. Do not proceed beyond a WARNING
notice until the indicated conditions are fully understood or met.
A CAUTION notice denotes a hazard. It calls attention to an operating procedure,
process or similar, which if not correctly performed or adhered to, could cause
damage to the generator or the application. Do not proceed beyond a CAUTION
notice until the indicated conditions are fully understood or met.
Caution, risk of electric shock. Ensure power to the generator has been removed
before proceeding.
Safety Notice to Users
These instructions must be read thoroughly and understood before
installation and operation of your Peak Generator. Use of the generator
in a manner not specified by Peak Scientific MAY impair the SAFETY
provided by the equipment.
When handling, operating or carrying out any maintenance, personnel
must employ safe engineering practices and observe all relevant local
health and safety requirements and regulations. The attention of UK
users is drawn to the Health and Safety at Work Act 1974, and the
Institute of Electrical Engineers regulations.
If the equipment is used in a manner not specified by the manufacturer,
the protection provided by the equipment maybe impaired.

Page 6
EU Declaration of Conformity
We Peak Scientific Instruments Ltd.
Of Fountain Crescent, Inchinnan, Renfrewshire, PA4 9RE
Hereby declare that, this declaration of conformity is issued under the sole
responsibility of the manufacturer.
Equipment Type: Nitrogen Gas Generator
Model Designator: Genius 1025
To which this declaration relates, is in conformity with the following applicable EU
Directives, harmonized standards, and other normative requirements.
• Low Voltage Directive 2014/35/EU
EN 61010-1: 2010 Safety Requirements for Electrical Equipment for Measurement,
Control and Laboratory Use.
• Electromagnetic Compatibility Directive 2014/30/EU
EN 61326-1: 2013 Electrical Equipment for Measurement, Control and Laboratory Use
– EMC Requirements. (Class A)
• Restriction on the use of certain hazardous substances in electronic equipment
(RoHS) Directive 2011/65/EU as amended by EU 2015/863.
• FCC 47 CFR Part 15 class A
Unintentional radiators; Conducted and Radiated emissions limits.
Signed for and on behalf of Peak Scientific by
Signed:
Name: Fraser Dunn
Position: Design Engineering Manager
Peak Scientific Instruments ltd,
Inchinnan, Renfrew, Scotland, PA4 9RE, UK.
Date: 15th November 2021

Page 7
UK Declaration of Conformity
We Peak Scientific Instruments Ltd.
Of Fountain Crescent, Inchinnan, Renfrewshire, PA4 9RE
Hereby declare that, this declaration of conformity is issued under the sole
responsibility of the manufacturer.
Equipment Type: Nitrogen Gas Generator
Model Designator: Genius 1025
To which this declaration relates, is in conformity with the following applicable UK
Statutory Instruments, Standards and other normative requirements.
• The Electrical Equipment (Safety) Regulations 2016 (SI 2016 / 1101) as amended.
BS61010-1:2010 Safety Requirements for Electrical Equipment for Measurement
Control and Laboratory Use.
• The Electromagnetic Compatibility Regulations 2016 (SI 2016 / 1091) as amended.
BS61326-1:2013 Electrical Equipment for Measurement , Control and Laboratory Use
– EMC Requirements.
• The Restriction of the Use of Certain Hazardous Substances in Electrical and
Electronic Equipment Regulations 2012 (SI 2012 / 3032) as amended.
Signed for and on behalf of Peak Scientific by
Signed:
Name: Fraser Dunn
Position: Design Engineering Manager
Peak Scientific Instruments ltd,
Inchinnan, Renfrew, Scotland, PA4 9RE, UK.
Date: 15th November 2021

Page 8
WEEE Compliance Statement
The Waste Electrical and Electronic Equipment (WEEE) Regulations SI 2013 No 3113
and or the Waste Electrical and Electronic Equipment (WEEE) Directive 2012/19/EU
apply to all electrical and electronic equipment placed on the market in the UK and EU
covered by the scope of regulations which can be found in the Government Guidance
Notes (PDF) produced by the Department for Business Innovation and skills for the UK
and here for Europe.
All PEAK products that are subject to the WEEE directive are compliant with the
WEEE marking requirement. Such products are marked with the “crossed-out wheelie
bin” symbol (shown below) in accordance with European standard EN50419. All
old electrical equipment can be recycled. Please do not dispose of any electrical
equipment (including those marked with this symbol) in general rubbish bins. Please
contact your dealer or distributor for clarity.

Page 9
CSA Compliance Statement
CSA Group (Canadian Standards Authority) is a Nationally Recognised Testing
Laboratory (NRTL), headquartered in Toronto Canada.
They are authorised to evaluate product to both their own and Underwriters Laboratory
(UL) standards and certify the product to be in compliance to the relevant standards.
Peak products are certified to the current in force revision of the following standards
in order to cover both Canadian and United States requirements for “Safety
Requirements for Electrical Equipment for Measurement, Control and Laboratory use,
Part 1: general Requirements”.
Canada: CAN/CSA C22.2 No 61010-1-12
United States: UL 61010-1
As a result the products covered by this statement are certified and listed by CSA
accordingly and are entitled to carry the CSA mark with both Canadian and United
States subscripts , as shown below on the product rating label.

Page 10
Technical Specification
Genius 1025
Environment
Minimum Operating Ambient Temperature 5°C (41°F)
Maximum Operating Ambient Temperature 30°C (86°F)
Maximum Altitude 3000m
Maximum Relative Humidity 80% Non-Condensing
Minimum Storage Temperature* -20°C (-4°F)
Maximum Storage Temperature* 60°C (140°F)
*NOTE – When taken out of storage the Generator should be allowed to acclimatize at room temperature
for a minimum of 3 hours before operation.
Please ensure generator is situated in a well ventilated environment
Generator Outlets
Nitrogen Maximum Flow 15 L/min / 0.53 cfm
Dry Air Maximum Flow 35 L/min / 1.24 cfm
Nitrogen Max Pressure 80 psi / 5.5 bar
Dry Air Max Pressure 110 psi / 7.6 bar
Particles <0.01µm
Phthalates NONE
Suspended Liquids NONE
Gas Outlets 2 x ¼” BSPP
Drain Outlet 1 x ¼” BSPP
Pressure Gauges 2
Electrical Requirements
Voltage 220-240v +/- 10%
Frequency 50 / 60 Hz
Current 5A
Input Connection C20 Plug
Power Cord C19 socket to local connection (13A minimum)
Pollution Degree 2
Insulation Category II
General
Dimensions cm (inches) WxDxH 713 x 600 x 750 mm 28.1 x 23.7 x 29.6''
Generator Weight Kg (lbs) 108.5 kg (239.3 lbs)
Shipping Weight Kg (lbs) 137 kg (302.1 lbs)
Table des matières
Autres manuels Peak Générateur portable

Peak
Peak Genius 1022 Manuel utilisateur

Peak
Peak NM30LA-MS Manuel utilisateur

Peak
Peak NM60L Manuel utilisateur

Peak
Peak i-Flow 6000 Series Manuel utilisateur

Peak
Peak Infinity 1051 Manuel utilisateur

Peak
Peak Genius XE SMZ Manuel utilisateur

Peak
Peak UM-NM300L Manuel utilisateur

Peak
Peak CNMG140L Manuel utilisateur

Peak
Peak NM20ZL Manuel d'utilisation

Peak
Peak i-Flow 6000 Series Manuel utilisateur