Peak NG3000 Manuel utilisateur

NG3000-5000 User Manual Rev 1 PN XXXXXXX 16/01/17
NG3000(A) & 5000(A)
User Manual

Contents
Change History 3
How to use this Manual 3
Introduction 4
Warranties and Liabilities 5
Safety Notices 6
Symbols 6
Safety Notice to Users 6
Declaration of Conformity 7
Environmental Declaration 8
Technical Specification 9
Unpacking 13
Installation 14
Generator Environment 14
Removing the generator from the shipping crate 15
Generator Overview 16
General Dimensions 16
Removal of Transit Brackets 17
Wall Mounting 18
Rear Connections 19
Electrical Connection 20
Fuse 20
Start-Up Sequence 21
Normal Operation 22
Unusual Operation 22
Service Requirements 23
Service Schedule 23
Peak Protected 24
Cleaning 25
Page 2

Page 3
Change History
Rev Comment Name Date
How to use this Manual
This manual is intended for end users and has been written as a reference document
where you can skip to the relevant information.
Users can refer to the contents page to find the relevant information.
Please review each of the following sections carefully.
Thank you for selecting Peak Scientific to meet your gas generation needs, and should
you require any further assistance or support please do not hesitate to contact Peak
Scientific or the Peak Partner from which you purchased your generator.

Page 4
Introduction
The NG range of ultra high purity nitrogen generators have been designed primarily for
GC applications and other applications requiring the highest purity nitrogen.
These models provide a source of Nitrogen gas with other features including:
• Available with or without an external compressor
• Contains self-regenerating Carbon Molecular Sieve purification
• The most convenient method of laboratory gas supply
• Gas is supplied on demand so generator works to your schedule
• Remove the hassle and safety concerns with ordering and replacing pressurized
cylinder gas
• 12 month comprehensive on-site warranty
Delivering flow rates of 3000cc/min or 5000cc/min, these generators come in two
variants, the standard model and the enhanced (A) models which feature an integrated
compressor, removing the need for an external air supply to be present in the lab.
To reach their ultra high purity nitrogen output these generators use Pressure Swing
Adsorption and Carbon Molecular Sieve. These separation technologies remove oxygen
and other impurities in air, delivering hassle-free, ultra high purity nitrogen, on-demand
for the lab.

Page 5
Warranties and Liabilities
1. The Company warrants that it has title to the Goods.
2. Subject to the provisions of this clause the Company warrants that the Goods
shall comply in all material respects with any specification referred to in the Order
Confirmation (as the same may be amended) and shall, subject thereto, be free
from defects in material and workmanship for the lesser of a period of twelve
months from the date of delivery or thirteen months from the date of dispatch
from the factory.
3. Save as provided in this clause and except where the Goods are sold to a person
dealing as a consumer (within the meaning of the Unfair Contract Terms Act
1977) all warranties, conditions or other terms implied by statute or common
law are hereby expressly excluded save to the extent they may not be lawfully
excluded. When the Goods are sold to a consumer within the meaning of the Unfair
Contract Terms Act 1977 their statutory rights are not affected by the provisions of
this clause.
4. In the event of the Customer making a claim in respect of any defect in terms of
clause 2 hereof the Customer must.
1. Reasonably satisfy the Company that the Goods have been properly installed,
commissioned, stored, serviced and used and without prejudice to the generality
of the foregoing that any defect is not the direct or indirect result of lack of repair
and/or servicing, incorrect repair and/or servicing, use of wrong materials and/or
incorrect spare parts
2. Allow the company to inspect the Goods and/or any installation and any relevant
packaging as and when reasonably required by the Company.
5. Subject to the Company being notified of any defect as is referred to in sub-
clause 2 hereof within a reasonable time of it becoming apparent and subject always
to the terms of sub-clause 4 hereof, the Company shall, in its option, replace or
repair the defective Goods or refund a proportionate part of the Price. The Company
shall have no further liability to the Customer (save as mentioned in sub-clause 6
hereof).
6. The Company shall be liable to indemnify the Customer in respect of any claim
for death or personal injury to any person in so far as such is attributable to the
negligence or breach of duty of the Company or any failure by the Company to
comply with the provisions of sub-clause 2 hereof.
7. Save as provided in sub-clause 2 hereof the Company shall not be liable in respect
of any claim by the Customer for costs, damages, loss or expenses (whether direct,
indirect, consequential or otherwise) or indemnity in any respect howsoever arising
including, but not by way of limitation, liability arising in negligence (other than
pursuant to clause 6 above) that may be suffered by the Customer or any third
party.

WARNING
WARNING
WARNING
WARNING
CAUTION
Page 6
Safety Notices
Peak Scientific Instruments cannot anticipate every possible circumstance which may
represent a potential hazard. The warnings detailed within this manual refer to the most
likely potential hazards, but by definition cannot be all inclusive. If the user employs
an operating procedure, item of equipment or a method of working which is not
specifically recommended by Peak Scientific, the user must ensure that the equipment
will not be damaged or become hazardous to persons or property.
Symbols
This manual uses the following symbols to highlight specific areas important to the safe
and proper use of the generator.
A WARNING notice denotes a hazard. It calls attention to an operating procedure,
process or similar, which if not correctly performed or adhered to, could cause
personal injury or in the worst case death. Do not proceed beyond a WARNING
notice until the indicated conditions are fully understood or met.
A CAUTION notice denotes a hazard. It calls attention to an operating procedure,
process or similar, which if not correctly performed or adhered to, could cause
damage to the generator or the application. Do not proceed beyond a CAUTION
notice until the indicated conditions are fully understood or met.
Caution, risk of electric shock. Ensure power to the generator has been removed
before proceeding.
Safety Notice to Users
These instructions must be read thoroughly and understood before
installation and operation of your Peak Generator. Use of the generator
in a manner not specified by Peak Scientific MAY impair the SAFETY
provided by the equipment.
When handling, operating or carrying out any maintenance, personnel
must employ safe engineering practices and observe all relevant local
health and safety requirements and regulations. The attention of UK
users is drawn to the Health and Safety at Work Act 1974, and the
Institute of Electrical Engineers regulations.
If the equipment is used in a manner not specified by the manufacturer,
the protection provided by the equipment maybe impaired.

Page 7
Declaration of Conformity
We Peak Scientific Instruments Ltd.
Of Fountain Crescent, Inchinnan, Renfrewshire, PA4 9RE
Declare that:
Equipment: Nitrogen Generator
Models: NG*000(A) Series
* Denotes any numeric value.
(A) Denotes compressor based model.
To which this declaration relates, is in conformity with the applicable EC directives,
harmonized standards, and other normative requirements.
• Low Voltage Directive 2014/35/EU
EN 61010-1: 2010 Electrical Equipment for measurement, control and laboratory use.
• Electromagnetic Compatibility Directive 2014/30/EU
EN 61326-1: 2013 Electrical Equipment for measurement, control and laboratory use.
All evaluation, testing and certification issued by:
York EMC Services Ltd
Donibristle Industrial Park
Dunfermline, Fife
KY11 9HZ
Signed: Name: Chris Pugh
Date: 03/02/2014 Position: Engineering & Operations Director

Page 8
Environmental Declaration
We Peak Scientific Instruments Ltd.
Of Fountain Crescent, Inchinnan, Renfrewshire, PA4 9RE
Declare that:
Equipment: Nitrogen Generator
Models: NG*000(A) Series
* Denotes any numeric value.
(A) Denotes compressor based model.
Is fully compliant with the following Directives
• 2012/19/EU WEEE (Waste of Electrical and Electronic Equipment)
• 2011/65/EU RoHS 2 (Restriction of Hazardous Substance)
Peak Scientific Instruments Ltd fully complies with its obligations towards the European
WEEE (Waste of Electrical and Electronic Equipment) Directive 2012/19/EU. These
obligations are being met within the B2B compliance group.
Peak Scientific Instruments Ltd has developed all reasonable ‘due diligence’ controls to
ensure that our products comply with the principles and requirements of the European
recast RoHS (Restriction of Hazardous Substances) Directive 2011/65/EU. Similar
directives in the United States and China, for example, have also been captured within
this program.
Where a specific certificate of compliance is required, this can be requested, on
a product serial number basis, directly from Peak Scientific Instruments Ltd, by
contacting us through our website on www.peakscientific.com
Signed: Name: Chris Pugh
Date: 03/02/2014 Position: Engineering & Operations Director

Page 9
Technical Specification
NG3000
Environment
Minimum Operating Ambient Temperature 5°C (41°F)
Maximum Operating Ambient Temperature 25°C (75°F)
Maximum Altitude 2000 m
Maximum Relative Humidity 80% Non-Condensing
Minimum Storage Temperature* 10°C (50°F)
Maximum Storage Temperature* 25°C (75°F)
*NOTE – When taken out of storage the Generator should be allowed to acclimatize at room temperature
for a minimum of 3 hours before operation.
Inlet Conditions
Minimum Air Pressure 8.2 bar (120 psi)
Maximum Air Pressure 8.8 bar (130 psi)
Generator Outlets
Maximum Gas Output Pressure 5.5 bar (80 psi)
Maximum Outlet Flow Rate 3000 cc/min (0.10 cfm)
Particles <0.01µm
Phthalates NONE
Suspended Liquids NONE
Gas Outlets 1 x ¼” BSPP
Start-Up Time For Purity 8 hours
Electrical Requirements
Voltage 230v or 110v
Frequency 50/60 Hz
Current 0.5 (1.2) A
Pollution Degree 2
Insulation Category II
General
Dimensions cm (inches) WxDxH 43 (16.9) x 41 (16.1) x 124 (48.8)
Generator Weight Kg (lbs) 77 (170)
Shipping Weight Kg (lbs) 107 (236)

Page 10
Technical Specification
NG3000A
Environment
Minimum Operating Ambient Temperature 5°C (41°F)
Maximum Operating Ambient Temperature 35°C (95°F)
Maximum Altitude 2000 m
Maximum Relative Humidity 80% Non-Condensing
Minimum Storage Temperature* 10°C (50°F)
Maximum Storage Temperature* 25°C (75°F)
*NOTE – When taken out of storage the Generator should be allowed to acclimatize at room temperature
for a minimum of 3 hours before operation.
Generator Outlets
Maximum Gas Output Pressure 5.5 bar (80 psi)
Maximum Outlet Flow Rate 3000 cc/min (0.10 cfm)
Particles <0.01µm
Phthalates NONE
Suspended Liquids NONE
Gas Outlets 1 x ¼” BSPP
Start-Up Time For Purity 8 hours
Electrical Requirements
Voltage 230v or 110v
Frequency 50/60 Hz
Current 3.6 (8) A
Pollution Degree 2
Insulation Category II
General
Dimensions cm (inches) WxDxH 43 (16.9) x 41 (16.1) x 124 (48.8)
Generator Weight Kg (lbs) 88 (194)
Shipping Weight Kg (lbs) 128 (282)
Ce manuel convient aux modèles suivants
3
Table des matières
Autres manuels Peak Onduleur

Peak
Peak PKC0M08 Manuel utilisateur

Peak
Peak Genius 1023 Manuel utilisateur

Peak
Peak PKC0AJ Manuel utilisateur

Peak
Peak PKC0AX Manuel utilisateur

Peak
Peak PKC0AW Manuel utilisateur

Peak
Peak Precision SL Manuel utilisateur

Peak
Peak Genius 3023 Manuel utilisateur

Peak
Peak PKC0AM Manuel utilisateur

Peak
Peak ABN2ZA Manuel d'installation et d'exploitation

Peak
Peak PKC0CF Manuel utilisateur