Reference Guide
8. Power Connection
OSDP Reference Guide
7. Communication Connections
POWER
HEART
LINK
BUS
+-BUS
+-
BUS
+-BUS
+-
POE IN
POE OUT
12-24
GND
+
BATTERY
+
-
0 1 L A
-
B NC NOC
+
-
0 1 L A
-
B NC NOC
OSDP OSDP
OSDP OSDP PORT2
PORT3
PORT4
PORT1
+
-
0 1 L A
-
B NC NOC
+
-
0 1 L A
-
B NC NOC
Ethernet - All Red controllers come with a built-in RJ45 connection for
network connectivity. Once connected, the Red controller is
Self-Discoverable from pdk.io using IPV6. Alternatively, you may use IPV4
or assign a static IP using pdk.io if desired.
A
Wireless (PN: RMW) and
PoE (PN: RMPOE) module
kits can be purchased for
optional communication
methods.
A
POWER
HEART
LINK
BUS
+-BUS
+-
BUS
+-BUS
+-
POE IN
POE OUT
12-24
BATTERY
+
-
0 1 L A
-
B NC NOC
+
-
0 1 L A
-
B NC NOC
+
-
0 1 L A
-
B NC NOC
+
-
0 1 L A
-
B NC NOC
OSDP OSDP
OSDP OSDP PORT2
PORT3
PORT4
PORT1
Powering Board - Connect unswitched AC power (120VAC 60Hz) to
terminals marked [L, G, N]. L to hot, N to neutral, G to ground. Use 14 AWG or
larger for all power connections. Secure green wire lead to earth ground.
A
Disclaimer -Installers must adhere to all regulations and hold the proper
state licenses prior to supplying voltage to the power supply.
Battery Backup is strongly recommended on all ProdataKey hardware. The
recommended backup battery for the Red Max is two 12V 12ah batteries.
AC1
AC
DC
NC
C
NO
NC
C
NO
eFlow102B
5A 250V
15A 32V
eFlow102NB
L G N
ALTRONIX CORP.
BROOKLYN,
N.Y. 11220
+ AUX –
TRIGGER EOL
SUPERVISED RESET
NO
GND
+
-
DC
+
-
BAT
AC Power
120VAC 60Hz
A
What is OSDP - Open Supervised Device Protocol (OSDP) is an access
control communications standard developed by the Security Industry
Association to improve interoperability among access control and security
products. OSDP brings heightened security and improved functionality. It is
more secure than Wiegand and supports AES-128 encryption.
OSDP Wire Specification - Four-conductor, twisted-pair cable with overall
shield is recommended to remain fully TIA-485 compliant at the maximum
supported baud rates and cable distances.
Note - It’s possible to reuse existing Wiegand wiring for OSDP. However,
using a simple stranded cable typical of Wiegand readers generally does not
meet the RS-485 twisted pair recommendations.
OSDP Multi-Drop - Multi-drop gives you the capability to accommodate
many readers by running one length of four-conductor cable, eliminating the
need to run wire for each wire.
Note - Four (4) is the maximum number of readers each port can support.
Note - Wiegand readers will not work when OSDP jumpers are installed.
Fire Input - To integrate the fire system into a controller, refer to wiring
diagrams at www.prodatakey.zendesk.com
Programming - After the controller is connected, access the configuration
software as instructed in the programming manual available at
www.prodatakey.zendesk.com
Reader Compatibility - Pdk does not require proprietary readers.
Controllers accept a Wiegand input, including biometric readers and
keypads. OSDP readers are supported by using the included jumper (see
OSDP reference guide). Contact pdk support if assistance is needed.
UL 294 Compliance - All equipment must meet appropriate UL certifications.
For UL-listed installations, all cable runs must be less than 30 meters (98.5’)
Part Number - R4E
Pdk Technical Support
Phone: 801.317.8802 option #2
Email: support@prodatakey.com
Knowledge Base: prodatakey.zendesk.com www.prodatakey.com
801.317.8802
REV 06132022
View the user manual here:
prodatakey.zendesk.com
PN:R4E
Copyright © 2022 ProdataKey Inc. All rights reserved. Pdk, Pdk io, and
the Red logos are trademarks of ProdataKey Inc.
Quick Start Guide