Item Content Page
1. Introduction to troubleshooting the PAT Overload Warning System DS 50 4
1.1 System Outline 4
1.2 Systems operation 6
1.3 Troubleshooting care 7
2. Getting started 9
3. LED 1-6 are all dim - Power supply problem 11
4. LED 2 is dim - No outgoing crane power 14
5.0 LED 3 - Cut off not functioning correctly 19
5.1 LED 3 lit all times - Cut off not functioning correctly 20
5.2 LED 3 is dim all times - Cut off not functioning correctly 28
6. LED 4 is dim - No power to proximity switch on hoist drum 37
7. LED 5 is dim or lit all times -Hoist proximity switch problem- 41
8. LED 6 is dim - Load cell power supply problem 43
9. Length sensor signal measurement 48
2
TSM DS 50-001/REV. C/ 031-300-190-002/ 04-17-2007

NOTE
THIS TROUBLESCHOOTING MANUAL “DS 50 - LEVEL 2” IS DESIGNED TO ASSIST
THE SERVICE OR MAINTENANCE PERSONAL IN IDENTIFYING THE PROBLEM AREA
OF A MALFUNCTIONING SYSTEM.
IN ORDER TO FOLLOW THE FOLLOWING INSTRUCTIONS THE PAT TEST
ADAPTER AND A DIGITAL VOLTMETER ARE REQUIRED IN ADDITION TO THE
REGULAR MAINTENANCE AND SERVICE TOOLS.
THIS TROUBLESHOOTING MANUAL MAY BE USED AS A CONTINUATION OF
TROUBLESCHOOTING MANUAL “DS 50 - LEVEL 1- BASICS.
THE KNOWLEDGE OF HOW TO USE A DIGITAL VOLTMETER IS ASSUMED.
WE SUGGEST THAT ONLY TRAINED MAINTENANCE AND SERVICE PERSONAL
PROCEED WITH THE TROUBLESCHOOTING DESCRIBED IN THIS MANUAL.
3
TSM DS 50-001/REV. C/ 031-300-190-002/ 04-17-2007

1. INTRODUCTION TO TROUBLESHOOTING THE
PAT OVERLOAD WARNING SYSTEM DS 50
1.1. SYSTEM OUTLINE
The PAT Overload Warning System Model DS 50 is designed to disable all functions
which may cause tipping or structural damage when the crane attempt to lift over
its limits.These limits are specified in the load capacity chart provided by the crane
manufacturer.
When the DS 50 system detects an overload condition the following crane
functions are disabled immediately.
a. telescope out
b. boom up and boom down
c. hoist up
To remove the overload condition the operator must achieve a safe working
condition.This can be achieved by lowering the load and repositioning the crane
or decreasing the radius by telescoping in. Observe that the radius can not be
decreased by lifting the boom. The boom up function is also disabled while
attempting to overload the crane.
The system design allows you to operate the crane in an emergency situation or
system failure without the DS 50 system in operation. In this situation leave the
crane electric switch in the off position and operate the crane manually. The
DS 50 Overload Warning System is not operative and can not warn the operator.
Warning
By switching the crane power switch off the DS 50 Overload Warning system
is by-passed. Operating the crane without using the range diagram may
result in property damage, injury or death.
The DS 50 system contains of a Central unit. The length sensor is part of the
Central unit. The load cell is supporting the hoist drum and used to measure the
load on hook.
4
TSM DS 50-001/REV. C/ 031-300-190-002/ 04-17-2007

1. INTRODUCTION TO TROUBLESHOOTING THE
PAT OVERLOAD WARNING SYSTEM DS 50
DS 50 SYSTEM
LENGTH CABLE
BOOM
LOAD CELL
PROXIMITY
SWITCH
BOOM
LIFT CYLINDER HOOK BLOCK
MAST
LENGTH CABLE MOUNT
LENGTH CABLE ENTRY
HOIST DRUM
CABLE CONNECTORS
LENGTH SENSOR - UNDER COVER-
Note: The drawing shows
the model FMTV-W.
The FMTV-C has only single
line capability.
DRAWING 1 - SYSTEM LOCATION (FMTV-WRECKER)
5
TSM DS 50-001/REV. C/ 031-300-190-002/ 04-17-2007

1. INTRODUCTION TO TROUBLESHOOTING THE
PAT OVERLOAD WARNING SYSTEM DS 50
1.2 SYSTEM OPERATION
The Microprocessor Central Unit operates as the control center of the system.
The length cable is connected to the boom nose. During telescoping the length
cable spools off a drum which turns the length potentiometer using a gear
assembly. The length potentiometer is a variable resistor which varies linearly
with the boom length. An angle sensor is built into the central unit which senses
the boom angle. The load cell provides the signal to calculate the load on hook.
The proximity switch located on the hoist drum switches to a different calibration
factor during spooling off the hoist rope. This will allow a steady load calculation
and compensates for the difference in the lever arm. All together the signals get
processed in the central Microprocessor unit where actual and rated load are
compared. Once the actual load exceeds the rated load the system de-energizes
a relay and disables the appropriate crane functions.
6
TSM DS 50-001/REV. C/ 031-300-190-002/ 04-17-2007

1. INTRODUCTION TO TROUBLESHOOTING THE
PAT OVERLOAD WARNING SYSTEM DS 50
1.3. Troubleshooting Care
• Keep in mind that in troubleshooting high quality electronic
components to use caution and necessary care while testing
and measuring DS 50 components and circuits of the crane electric's.
• Tools and test equipment must be in good order and shall be inspected
on a regular basis.
• Follow all safety instructions according to crane manufacturers
handbooks and safety instructions. Obey recommended practice and
safety standards applying to the job site.
• Secure the working area prior to testing and servicing the system.
• Never remove the load cell without firm support holding the hoist drum.
• Never let the length cable snap back to the central unit. The length
sensor drum is under high tension.
Warning
DS 50 Overload Warning System service and repair work shall be
performed by trained and authorized personal only.
7
TSM DS 50-001/REV. C/ 031-300-190-002/ 04-17-2007

1. INTRODUCTION TO TROUBLESHOOTING THE
PAT OVERLOAD WARNING SYSTEM DS 50
Crane power switch Crane electric
junction box
Outrigger extend
proximity switches-
FMTV-Cargo only.
Hook block storage position
DRAWING 2 - Crane storage position
Note: The drawing shows
the model FMTV-W.
The FMTV-C has only single
line capability.
Caution !
Crane is shown folded for transportation.
For lifting operations the mast has to be in upright position
and the hook lifted out of the transportation storage.
8
TSM DS 50-001/REV. C/ 031-300-190-002/ 04-17-2007

2. Getting started
The following drawing explains the components on the PAT test adapter (031-300-060-014).
This troubleshooting manual will refer to this drawing several times.
Positive voltage
terminal for DVM
Input connector
- connect input cables -
negative voltage
terminal for DVM
Status LEDs
Connector cables
Plugs - connect to system
Load cell zero point test switch
DRAWING 3: PAT Test adapter (031-300-060-014)
for DS 50-001
9
TSM DS 50-001/REV. C/ 031-300-190-002/ 04-17-2007

2. Getting started
Locate the PAT DS 50 overload warning system. Switch the crane electrical power off. Refer to
drawing 2 in section 1 to locate the crane electric interface box with electrical power switch.
Unplug the three cables from the central unit. Plug those cables into the test adapter sockets.
Plug the test adapter cables into the central unit connectors. Tighten all connections before you
switch the power on.
Switch crane power on and wait for at least 20 seconds. The system performs a self test every time
the power is switched on. During the self test period you may see some LEDs blinking. The system
performs a test routine and switches relays and components. It is normal to see LEDs switching on
and off.
After the self test is completed check the LEDs and their performance.
Refer to the next page for further investigation of the condition
10
TSM DS 50-001/REV. C/ 031-300-190-002/ 04-17-2007
Autres manuels pour DS 50
4
Table des matières
Manuels Système de levage populaires d'autres marques

morse
morse 82H-124 Manuel utilisateur

Braun
Braun NL955 Series Manuel utilisateur

haacon
haacon 1889.10 Manuel utilisateur

Protekt
Protekt AT 252 Manuel utilisateur

R. Beck Maschinenbau
R. Beck Maschinenbau HS 600 Manuel utilisateur

Nova Technology International, LLC
Nova Technology International, LLC NAS Series Manuel utilisateur

Genie
Genie Z-60/34 Manuel utilisateur

Screen Technics
Screen Technics INTERFIT Vertical Up Lift Manuel utilisateur

Mortuary Lift
Mortuary Lift ULTIMATE 1000 Manuel utilisateur

Custom Equipment
Custom Equipment Hy-Brid 3 Series Manuel de programmation

Custom Equipment
Custom Equipment Hy-Brid Lifts 2 Series Manuel de programmation

Hy-Brid Lifts
Hy-Brid Lifts HB-P3.6 Manuel de programmation