OZTI OFGI 4090 Manuel utilisateur

PRODUCTION YEAR: SERIAL NO:
PRODUCTION SITE : Beylikdüzü Eski Hadımköy Yolu 1.Km Büyükçekmece İstanbul/TÜRKİYE
Phone : 0090 212 886 78 00 (8 Hat-Lines) Fax : 0090 212 886 66 29
Published on : 01.01.2013 VER:V13.01 1/16
FRYER (GAS)
USER’S MANUAL
Our website: www.oztiryakiler.com e-mail: export@oztiryakiler.com.tr
MANUFACTURER : ÖZTİRYAKİLER MADENİ EŞYA SAN. VE TİC A.Ş.
-1783

TABLE OF CONTENTS
2/16
PAGE NR. TOPICS
1 COVER PAGE
2 TABLE OF CONTENTS
3 INTRODUCTION
4 TECHNICAL DATA
5 MAIN DIMENSIONS AND WARNING SIGNS
6-7 SAFETY DETAILS
8 TRANSPORTING AND MOVING
9-10 INSTALLATION OF THE APPLIANCES
11 CONTROL BOARD
12-13 OPERATION OF THE APPLIANCES
14 CLEAN-UP AND MAINTENANCE
15 CHANGING THE GAS SYSTEM
16 TERMS OF WARRANTY

INTRODUCTION
☞Please read and ensure that your operation personnel also reads this user’s
manual care fully before installing and using the appliance. If the appliance is
operated without reading the user’s manual, the appliance will not be covered
by the warranty.
☞The manual containing information about installation, usage and maintenance
of our product you purchased should be read carefully. Please ensure that
power supply connections to the appliance are already installed by qualified
personnel according to local legislation, before our authorized service
personnel arrives for the installation of the appliance.
☞If you are confused or you don’t have enough information
please get in touch with authorized service by phone.
☞Please keep in mind that, if the service personnel is delayed
at your site, related expenses and delay costs will be charged to
you on hourly basis.
☞We hope that you will get the best performance from our product…
Dear User,
Thank you for purchasing our appliance and for your reliance upon our
company. Our appliances are used in professional kitchens in 75 countries.
Our appliances are produced in compliance with international standards.
Important notice: Please read and ensure that the users read this user’s
manual in order to achieve the desired performance in line with your
expectations and to use your appliance for long years. Please take the
warnings mentioned above into consideration before calling for service...
3/16

TECHNICAL DATA
4/16
YOUR
PRODUCT'S TYPE
☞
OFGI 4090
OFGI 8090
OFGI 4070
OFGI 8070
MAIN
DIMENSIONS
(mm) 400X900X 850 800х900х 850 400x700x850 800x700x850
HEAT POWER
(KW) (Hİ) ΣQN 22 2x22=44 10 2x10=20
TYPE А1А1А1А1
GAS INLET (inch) ½” R ½” R ½” R ½” R
THERMOSTAT
(ºС) 110-190 110-190 110-190 110-190
SAFETY
THERMOSTAT
(ºС) 230
230 230
230
CAPACITY 22 22+22=44 12 12+12=24
FRYING
CAPACITY
Maximum
(kg/batch)
3 6 2 4

MAIN DIMENSIONS AND WARNING SIGNS
Figure 1: Main Dimensions and Warning Signs
5/16
HOT SURFACE SAMPLE LABEL
☞MODEL OFGI 4090

SAFETY DETAILS
☞Do not leave the appliances under direct
sunlight.
☞The appliances should only be operated
under a chimney hood.
☞If the appliances is operated using a LPG
gas cylinder, the distance between the
appliances and gas cylinder should be
minimum 50 cm.
☞Any kind of flammable solid and liquid
material (cloths, alcohol and derivatives,
petrochemical products, wooden and plastic
materials, cutting blocks, curtains etc.)
should never be held near the appliances.
☞You can use this appliances simultaneously
together with other products of ours.
☞Do not clean up the appliances with pressure
water
☞This appliances should be installed in line
with effective regulations and only be
operated in well ventilated places. Please
refer to the instructions before installing and
operating the appliances.
☞This appliances is designed for industrial
use and should only be operated by personnel
trained according to this manual.
6/16

SAFETY DETAILS
☞The appliances should not be handled
by unauthorized persons except for the
manufacturer or authorized service.
☞In case of fire or flame in the area where the
appliances is operated, act without panic, close
gas valves, turn off the power switches and
use a fire extinguisher. Never use water to
extinguish the fire, water will cause the fire to
spread more faster.
☞Oil spilled on the ground during use must be
wiped away. Otherwise it will cause the ground to
be slippery.
☞Gas smell indicates gas leakage. In this case
close appliances valve and main gas valve,
open the doors and windows, do not use
sparkling material like power switches. Please
call for our service swiftly.
7/16

TRANSPORTING AND MOVING
☞The 900 series should be moved with the help of
vehicles like fork lift.
☞The appliances should be transported by placing the
feet of the fork lift under the appliances.
☞If the transported distance is far, the vehicle should be
moved slowly and the appliances should be fixed on
palette or supported in order to prevent jolt.
☞Do not hit or drop the products when moving.
CHANGING THE LOCATION ;
Vehicles installed by an authorized
service CANNOT BE MOVED
ELSEWHERE, ITS CONNECTION
HOSES AND CABLES CANNOT BE EXTENDED OR
REPLACED except by an authorized service.
8/16

If this appliances located near to any wall, separation, kitchen
furniture, decorative coating etc. the distance in between
should be min.20 cm. and if those are coated with fireproof heat
insulating material, the distance should be min. 5 cm. It is strongly
recommended that fire safety protection instructions are observed.
INSTALLATION OF THE APPLIANCES
☞The feet of the appliances should be height adjusted and the
appliances should be ensured to operate in a leveled position.
☞All of the gas connections of the appliances should complying with ISO
7-1 or ISO 228-1.
☞Gas connections of the appliances should be carried out by an
authorized service personnel, only after controlling its label according
to gas type and pressure. Connections of different type and/or at
different pressure should not be done.
9/16
All of the items mentioned below in connection with the
installation of the appliances should be carried out by
authorized service personnel.
THE DISTANCE BETWEEN THE GAS CYLINDER AND THE APPLIANCES SHOULD BE MIN. 50 cm.
LPG
50

☞Gas connection inlet dimensions are defined at the table of TECHNICAL
DATA.
☞After the appliances is connected to the system gas usage should be
checked with soap bubble method.
☞Air inlet adjustment is done by the authorized personnel if necessary, after
checking the appliances.
INSTALLATION OF THE APPLIANCES
10/16
☞Nominal power of the device cannot be changed upon
customers request.Any modification made on valves and
injectors, leaves the device out of warranty coverage.
☞Do not let use spare parts not being original. Installing spare
parts not supplied by our company, will leave the device out of
warranty coverage.
GAS CONNECTION DIMENSIONS
GAS USED
G20 (NETWORK
NATURAL GAS)
G30 (LPG GAS)
OFGI 40X90
A: 220 mm
B: 30 mm
OFGI 80x90
A: 185 mm
B: 125 mm
A
Gas Inlet B
Ce manuel convient aux modèles suivants
3
Table des matières