OxyGo CPAP Sanitizer+ Manuel utilisateur

Product Instructions
www.oxygo.life
Cleans and sanitizes so you can keep going.

IMPORTANT SAFEGUARDS
Warning!
Read all instructions before using this product!
WARNING: TO AVOID RISK OF ELECTRICAL SHOCK, ALWAYS MAKE SURE THE
PRODUCT IS UNPLUGGED BEFORE ATTEMPTING TO MOVE OR CLEAN THE
DEVICE
When using any electrical appliance, basic safety precautions should always be
followed to prevent risk of electrical shock, including the following:
SAVE THESE INSTRUCTIONS.
This manual contains important safety and operating
instructions for this product.
To protect against risk of electrical shock, do no immerse cord, plug, power
adapter, or the OxyGo CPAP Sanitizer+ device in water or other liquid.
Do NOT operate appliance if the power cord or plug is damaged. Any
damaged part must be repaired or replaced by the manufacturer or an
authorized service provider before use. Regularly check the power cord,
plug, and power adapter to ensure that they are undamaged.
Do NOT run cord under carpeting. Do NOT cover cord with throw rugs,
runners, or other similar coverings. Arrange cord away from traffic areas
where it will not be tripped over.
Do NOT use outdoors or on wet surfaces.
Do NOT place near a source of heat.
WARNING: Choking Hazard. Small Parts. Keep away from children under 3
years.
Do NOT use this product other than for its intended use and in accordance
with the product instructions.
CAUTION: This product is not intended for commercial, professional, or
industrial use. This product is not intended for the sanitation of medical or
dental equipment including surgical devices, scalpels or other medical
devices.
1.
2.
3.
4.
5.
6.
7.
8.
**Guaranteed safe for all major CPAP machines if used as directed.**

Product Instructions
OxyGo CPAP Sanitizer+
Congratulations on your purchase of an OxyGo CPAP Sanitizer+
and device cleaner!
Please carefully review the operation and safety information for the
OxyGo CPAP Sanitizer+ and follow all recommendations. Use of this
product in a manner other than described in these product instructions
or specified by the manufacturer may hinder safety protection provided
by this equipment.
Please review and familiarize yourself with the function diagrams that
identify the buttons, display, and features of the device. They will be
frequently referred to in this manual and are important in understanding
the operating instructions.
The OxyGo CPAP Sanitizer+ cleaner has the capability of sanitizing
surfaces by using UV-C (Ultraviolet Light) and / or Activated Oxygen.
The user can choose the mode that will perform best for them. These
modes can be used through either a manual mode or an automatic
mode.

Table of Contents
Items included
Key Parts
Menu Panel
Operating Instructions
Setting Clock
Open/Close Lid
Manual Mode Settings
UV-C sanitizing in manual mode
Activated Oxygen sanitizing in
manual mode
UV & Activated Oxygen sanitizing
in manual mode
Auto Mode Settings
Replacing carbon filters
Routine Care
F.A.Q.
................................................................4
................................................................5
...............................................................6
................................................................7
................................................................7
................................................................7
................................................................8
................................................................8
..............................................................9
.............................................................11
..............................................................12
.............................................................13
..............................................................14
..............................................................15
3

What comes with your
OxyGo CPAP Sanitizer+
OxyGo CPAP Sanitizer+ Device
Replacement filters
Product instructions
Power Cord 1700-5060
Power adapter (110v) 1700-5061
1700-5040
Screwdriver for filter changes
1700-5050
4
1700-5010
1700-5051

1
2
2
6
Key Parts
DC Input1.
2. Activated carbon filter
3. UV Light
4
3
5
4. Open button
5. External sealing lid
6. Internal sealing lid
5

Sanitizing...
Remaining
UV
O3
Min
AM
Timer
k
c
b
a
j
ihg
f
d
e
a. Remaining sanitizing time
b. UV indicator
c. Activated Oxygen indicator
d. Manual/Timer mode
h. +/Up
i. -/Down
j. Start/Pause
k. Clock
e. Working indicator
f. Timer
g. Manual
6
Menu Panel
Start/Pause Down Up Manual Timer

Setting the Clock
How to set the clock.
Press and hold the timer button then release the button.
The hour will begin flashing which will allow the number to be
changed up or down.
Press the + button to increase the time or the - button to decrease
the time. This will adjust the hours with the hour display flashing.
Then select AM or PM.
Once the display has flashed 4 times the adjusted hour time will be
saved.
To adjust the minutes press and hold the timer button again to
allow the minutes to flash.
Press the + button to increase the time or the - button to decrease
the time. This will adjust the minutes with the minute display
flashing.
Once the display has flashed 4 times the adjusted minute will be
saved.
This completes clock set-up.
1.
2.
3.
4.
5.
6.
7.
8.
Opening and closing the lid
Note: When opening and closing the lid of the OxyGo CPAP Sanitizer+,
place hands on the sides or front of the lid to avoid unintentionally
changing any settings.
7
Operating Instructions

How to perform UV-C sanitizing in manual mode
To perform UV-C (ultraviolet light) sanitizing ONLY follow these
instructions.
Open the lid of the device by pushing the large “OPEN” button on
the front of the device.
Place items to be sanitized using UV light into the chamber of the
OxyGo CPAP Sanitizer+. These items can include CPAP masks and
hoses, remote controls, toothbrushes, combs, pens, and any other
item to be sanitized that will fit inside of the chamber. NOTE: For
best results, avoid stacking items when placing them into the
chamber to allow for maximum UV exposure on all surfaces.
Once all items to be sanitized are inside the chamber, close the lid
of the OxyGo CPAP Sanitizer+.
Press the Start/Pause button on the lid of the OxyGo CPAP
Sanitizer+ to turn the device on.
Press the manual button to change the desired mode. Press the
manual button until the UV symbol is shown in the upper right
corner of the display. The UV symbol should be the only symbol
shown in this area.
The UV mode can run for 5, 10, or 15 minutes. To choose the
length of time, press the + or – button to adjust to desired length of
minutes. When the desired length is selected stop pressing the
button and allow the number to remain on the screen. NOTE: While
a 5-minute cycle is usually sufficient to thoroughly sanitize most
items, you may choose a longer cycle when sanitizing larger or
multiple items.
Press the Start/Pause button to begin the UV cycle.
Once pressed the clock will count down the time until the end of
the cycle.
When the cycle is completed 4 dashes will appear on the screen to
show that the cycle is complete.
Open the lid by pressing the large Open Button on the front of the
device and safely remove the items.
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
8
Manual Mode Settings

9
Manual Mode Settings
How to perform Activated Oxygen sanitizing in manual
mode
To perform Activated Oxygen sanitizing ONLY follow these instructions.
Open the lid of the OxyGo CPAP Sanitizer+ by pushing the large OPEN
button on the front of the device.
Open the blue internal sealing lid inside the chamber by lifting and
partially rotating it counterclockwise. This blue sealing lid is in the top
right corner of the bottom of the chamber. This will allow the Activated
Oxygen into the chamber.
Place items to be sanitized using Activated Oxygen into the chamber of
the OxyGo CPAP Sanitizer+. These items can include CPAP masks,
hose, humidifier components and most other plastic or rubber items.
Do not use Activated Oxygen to sanitize metal, electronics, or other
sensitive materials as such items could be damaged.
With the items to sanitize inside of the chamber close the lid of the
OxyGo CPAP Sanitizer+.
Press the Start/Pause button on the lid of the OxyGo CPAP Sanitizer+ to
turn the device on.
Press the manual button to change the desired mode. Press the manual
button until the O3 (Activated Oxygen) symbol is shown in the upper
right corner of the display. The O3 symbol should be the only symbol
shown in this area.
The Activated Oxygen cycle can run for 20, 30, or 40 minutes. To
change the cycle time, press the + or – button to adjust to the desired
cycle time. When the desired length is selected stop pressing the button
and allow the number to remain on the screen. NOTE: While a 20-minute
cycle is usually sufficient to thoroughly sanitize most items, we
recommend choosing a longer cycle when sanitizing larger or multiple
items.
Press the Start/Pause button to begin the Activated Oxygen disinfecting
cycle.
Once pressed the clock will count down the time until the end of the
cycle.
1.
2.
3.
4.
5.
6.
7.
8.
9.
Continued on next page.