SCCP05-050 Owner’s Manual
Overload Time (Loads > 5Adc)
5 min for Load > 100%,
0.1 sec for Load > 125%
Battery Reversal, PV Reversal
Load Disconnect (Automatic Reset)
Low Battery, High Battery,
Overload
Load Disconnect (Manual Reset)
Overload (after 3 automatic
resets)
Low Battery Load Disconnect
Low Battery Load Reconnect
High Battery Load Disconnect
Short Circuit Current (maximum)
Battery Type ( jumper-
selectable)
12 or 24 Vdc; automatically detected
Conversion Efficiency
(maximum)
Bulk and Absorption
Voltages
(maximum)
for Battery Types
Charging Current (maximum)
Temperature Compensation
(range)
-5 mV / °C / battery cell*
NOTE: Enabled by removing battery jumper; loads turned off while equalizing
NOTE*: Occurs every 60 days, or following a low battery load disconnect
Equalization Voltage (maximum)
Possible Remedies (perform in order shown)
1) Check battery connections 2) Check PV voltage and connections 3) Allow charger to cool
No LED indicators with PV power available
1) Check battery voltage at controller terminals 2) Check panel voltage at controller terminals
1) Disconnect PV 2) Disconnect battery 3) Disconnect load
4) Reconnect battery 5) Reconnect PV 6) Reconnect load
1) Disconnect loads 2) Charge battery
Charging to wrong voltage
1) Check position of battery selection jumper
159 mm (6.3”) x 68 mm (2.6”) x 25 mm
(1.0”)
Terminal Size(PV and
battery)
NOTE: Larger cables should be used if battery cables exceed 3 m length
NOTE: Battery cables must be twisted together during installation
0 to 95% RH non-condensing
Minimum 25Ah at C/5 discharge rate
CE, EN 61000-6-1,EN 61000-6-3, IEC/EN 62109-1
*Number shown is factory default setting.