This ”Directions for use” contains following product:
Chimney fan CF 180 C
• The fan must be installed according to the assembly
instruction.
• The fan should be installed in a safe way so it not
come loose or cause vibrations.
• The fan should be installed in a way that makes
service and maintenance easy.
• To regulate the speed a transformer, a speed con-
troller or a frequency converter can be connected.
• A wiring diagram is applied on the inside of the
junction box.
• Electrical installations must be connected to a
locally situated tension free switcher.
• Electrical installations must be made by an autho-
INSTALLATION
The chimney fan CF 180 C is designed to cope with
high flue gase temperature in a high corrosive envi-
ronment. It is used to increase the up draught in a
chimney or flue connected to a stove, open fireplace
or boiler.
CF 180 C is:
• equipped with a maintenance-free external rotor
motor for temperatureclass F. The ball bearings are
sealed for life.
• equipped with outlet for flue gas which are
pointed diagonally upwards, to prevent fouling of
roof.
• equipped with angle brackets that fits both circular
and rectangular chimney ducts, with intervals of
100-200 mm resp. 100-150 mm.
• adjusted for chimneys of steel or brick.
• made of stainless steel (SS2333-02) to prevent
attacks from a harmful substances in the flue gas.
• constructed to withstand flue gases of up to
200 C° continously.
• easy to open for cleaning the impeller and duct with
the swing-out design. If a major cleaning is neces-
sary,
just a few simple operations and the entire fan can
be lifted out of the housing.
• sealed, for maximum capacity, with a mineral wool
board between the fan and chimney.
• equipped with a fan for effeciency cooling of the
fan motor. The motor and cooling fan are placed se-
cluded from the flue gas.
• possible to speed control by thyristor regulator or
transformer.
• equipped with an security wire to avoid accidents of
UNIT DESCRIPTION
fan falling down.
• The fan is adapted to transport flue gases with a
temperature of maximum 200 C°.
•The fan must be operating when firing.
• The fan is equipped with ball bearing mounted ex-
ternal rotor type induction motor.
• The fan is adjusted for chimneys of steel or brick.
• The fan is as standard single-phase, 230 V,50 Hz.
• The fan should be installed horizontally.
USAGE