Optek TF56 Manuel utilisateur

Instruction Manual
optek-sensors TF56
Version 02.2008_1.1US
PN: 1004-2007-02
optek-Danulat GmbH
Emscherbruchallee 2
45356 Essen
Germany
Phone: +49-201-63409-0
Fax: +49-201-63409-999
E-Mail: inf[email protected]e
Internet: www.optek.com

Preface
optek-sensors TF56, Version 02.2008_1.1US, 06.02.2008
www.optek.com
Preface
This instruction manual is written to assist the user in proper procedures for
trouble-free operation.
Itis explicitlypointed out that optek-Danulat GmbH assumes no responsibilityfor
loss or damage caused due to improper use of this instruction manual or
products described herein.
This manual is protected by copyright. However, the user may produce copies
and translations if required for correct operation of the products.
On request, this manual is available in other languages as well as in digital
format (Acrobat®Reader 5.0 required).
Our products are being continuously improved. Technical data is subject to
change without notice.
Essen, August 2007

Preface
optek-sensors TF56, Version 02.2008_1.1US, 06.02.2008
www.optek.com
For further inquiry, feel free to contact us or our distributing partners at
any time:
Germany
optek-Danulat GmbH
Emscherbruchallee 2
45356 Essen / Germany
Phone: +49-201-63409-0
Fax: +49-201-63409-999
E-Mail: info@optek.de
Netherlands
optek-Danulat bv
Grote Brugse Grintweg 12a
4005 AH Tiel / Netherlands
Phone: +31 -344 -683800
Fax: +31 -344 -653950
E-Mail: info@optek.nl
USA
optek-Danulat Inc.
N118 W18748 Bunsen Drive
Germantown WI 53022 / USA
Phone: +1 262 437 3600
Toll free call: +1 800 371 4288
Fax: +1 262 437 3699
E-Mail: info@optek.com
Singapore
optek-Danulat Pte. Ltd.
25 Int’l Business Park
#05-109-f German Centre
Singapore 609916
Phone: +65 6562 8292
Fax: +65 6562 8293
E-Mail: info@optek.com.sg
Internet: http://www.optek.com

Table of contents
- I -
optek-sensors TF56, Version 02.2008_1.1US, 06.02.2008
www.optek.com
Table of contents
Preface
1 System overview .................................................................................1
2 Using the instruction manual .............................................................2
2.1 Validity of the instruction manual....................................................... 2
2.2 Pictograms and signal words............................................................. 3
2.3 Note regarding return of the sensor................................................... 4
3 Intended use ........................................................................................5
4 Description of the TF56 sensor ..........................................................6
5 Technical data and exploded views ...................................................8
5.1 Exploded view of TF56 sensor......................................................... 11
5.2 Exploded view of TF56-HT sensor................................................... 12
5.3 Exploded view of TF56-PV sensor................................................... 13
5.4 Exploded view of TF56-HT-PV sensor............................................. 14
6 Installation ..........................................................................................15
6.1 Standard sensor bodies - installation instructions............................ 15
6.2 Installation of the sensor.................................................................. 17
6.3 Air purge.......................................................................................... 18
7 Connection to converter 556 ............................................................19
8 Faults ..................................................................................................23

Table of contents
- II -
optek-sensors TF56, Version 02.2008_1.1US, 06.02.2008
www.optek.com
9 Maintenance .......................................................................................25
9.1 Preventive maintenance.................................................................. 25
9.2 Exchange of lamp module ............................................................... 26
9.3 Exchange of detector module.......................................................... 27
9.4 Return to operation after the exchange of lamp module
and detector module........................................................................ 28
9.5 Spare parts and accessories ........................................................... 29
9.5.1 Lamp modules / wavelength modules /
detector assembly ................................................................29
9.5.2 Standard window ..................................................................30
9.5.3 Gaskets (not wetted) ............................................................30
9.5.4 Screw sets ............................................................................31
9.5.5 Small part sets ......................................................................31
9.5.6 Installation material ..............................................................31
9.5.7 Accessories cable sets .........................................................32
10 Disposal ..............................................................................................33
11 Appendix ............................................................................................34
11.1 Declaration of conformity................................................................. 35
11.2 TÜV NORD CERT GmbH "GS-mark"............................................... 36
11.3 QM system certificate...................................................................... 37
11.4 Decontamination declaration ........................................................... 38
11.5 Response via fax............................................................................. 40

Using the instruction manual
- 2 -
optek-sensors TF56, Version 02.2008_1.1US, 06.02.2008
www.optek.com
2 Using the instruction manual
2.1 Validity of the instruction manual
This instruction manual is valid for TF56 sensor and its variants. There are the
following variants:
•HT
•PV
•HT-PV
•SF
Abbreviations mean the following sensor options:
• HT high temperature
• PV purge varivent (air purge connections at sensor)
• SF silicone-free version with restricted temperature ratings
Follow the instruction manual for every operation. If the sensor is not used as
described in this instruction manual, your safety and the sensor function could
be affected.
To keep up reliability of the product, enhance its life cycle and avoid down times,
you have to follow the instructions given in this manual.
Furthermore, please follow the existing accident prevention and environmental
protection instructions, as well as recognized technical instructions for safe and
professional working.

Using the instruction manual
- 3 -
optek-sensors TF56, Version 02.2008_1.1US, 06.02.2008
www.optek.com
2.2 Pictograms and signal words
Especially important information in this instruction manual is marked with the
following pictograms:
Danger!
This pictogram indicates immediate danger to life and health of persons.
The text next to the symbol gives information on how to avoid bodily injuries.
If the possible cause of risk can be specified, the corresponding pictogram
preceeds instructions:
Danger!
Electrical voltage.
This pictogram indicates danger due to electrical voltage.
Caution!
This pictogram indicates information on how to avoid material damage.
Note!
This pictogram indicates instructional or general advice.

Using the instruction manual
- 4 -
optek-sensors TF56, Version 02.2008_1.1US, 06.02.2008
www.optek.com
2.3 Note regarding return of the sensor
In the appendix of this instruction manual you find a declaration regarding the
decontamination of the sensor. Please fill out that declaration and add it to
sensor packaging when you return the sensor.
Note!
optek can only accept the returned sensor with the filled out and signed
decontamination declaration enclosed in the package.

Intended use
- 5 -
optek-sensors TF56, Version 02.2008_1.1US, 06.02.2008
www.optek.com
3 Intended use
The optek-sensors TF56 and their variants are to be applied only as scattered
light turbidimeters for liquids and gases in inline applications according to the
technical data.
The use of the sensors in hazardous locations is prohibited.
You can purchase flameproof sensors for hazardous locations from optek. For
these sensors, special instruction manuals are delivered with the sensor.
Unauthorizedconstructionalchanges,additionalfittings orrebuildingsregarding
the sensor are prohibited. The only exception are rebuildings into one of the
variants listed in the chapter "Validity of the instruction manual". Changes to and
interference with the converter program are prohibited as well.
To lay sensor cables underground without protection is prohibited.
The manufacturer is not liable for damage resulting from use contrary to
intended use.
Following this instruction manual is part of the intended use.
Table des matières
Autres manuels Optek Capteur de sécurité