Once BioShift Manuel utilisateur

BioShift®Pass-Through UV-C
Chamber - Small
Instruction Manual
This manual provides BioShift®Pass-Through Chamber user
guidelines and additional operation instructions for agricultural/industrial use.
For Service or Parts Call Your
Sales Representative or Contact us at:
T +1 (763) 381-5621
F +1 (763) 381-5698
E info@once.group
www.once.group
Once Inc., a Signify company
15255 23rd Ave. N.
Plymouth, MN 55447
United States of America

TABLE OF CONTENTS
Introduction ................................................................................................................................................ 2
Features ..................................................................................................................................... 2
Specications ............................................................................................................................................. 3
Safety ......................................................................................................................................................... 4-5
Installation ................................................................................................................................................... 6
Touchscreen Display ............................................................................................................................ 7-9
Home Screen Components ................................................................................................ 7
Maintenance Screen Components .................................................................................. 8
Settings Screen Components ............................................................................................ 9
Programming ............................................................................................................................................10
Cycle Time .............................................................................................................................. 10
Sleep Timer ............................................................................................................................ 10
Maintenance ...................................................................................................................................... 11-13
Alert Notications / Errors ............................................................................................... 11
Check Lamp Life ................................................................................................................... 12
Order Replacement Lamps .............................................................................................. 12
Changing Lamps ................................................................................................................. 12
Reset Lamp Life .................................................................................................................... 13
Cleaning .................................................................................................................................. 13
UVDoseVerication..............................................................................................................13
Operating .................................................................................................................................................. 14
Warranty ............................................................................................................................................. 15-22
Contact Information .............................................................................................................................. 23

INTRODUCTION
The BioShift®Pass-Through UV-C Chamber is an easy-to-use bio-security tool made to
be used alongside germicidal disinfecting sprays/fogs, chemical cleaners, unsecured
access panels and other already in place bio-security practices. It is designed to x key
vulnerabilities within agriculture facilities, while enhancing protocols by killing viruses
and other pathogens in a recommended time of 5 minutes, before they can enter your
bio-secure farm facility.
The chamber has been veried to inactivate common pathogens by a nationally -
recognized testing laboratory specializing in antimicrobial, biocidal and virucidal
eectiveness.
Note: UV-C radiation is only eective on hard surface objects. It does not penetrate through
materials and is unable to kill bacteria, viruses and pathogens on shrouded objects, interior
cavities of objects and areas of objects that are not exposed to the proper intensity and
duration of UV-C radiation. Thus, the BioShift®Pass-Through UV-C Chamber should be used
in addition and as a complement to sterilization products and procedures and NOT as a
replacement.
Features
• Uses Ultraviolet Germicidal Irradiation, the process of killing viruses through light
• Easy-to-use, one button operation
• Pass-through chamber deactivates the DNA
• Heavy-duty and durable stainless steel chamber
• Improves eectiveness of the Danish Entry or Shower in/Shower out bio-security
protocols
2

SPECIFICATIONS
Dimensions
Outside 29.5”wide x 23” deep x 23.6”high (750 x 584 x 600 mm)
Weight 110 lbs (50 kg)
Functional
Operating Power / Current 80W / 667 mA
Standby Power / Current 7W / 100 mA
Input Voltage 110-125VAC, 50/60 Hz (voltage uctuation ±10%)
Power Connection Connect to branch circuit rated 20A max
Fuse Protection 10 A at 250V
Environmental
Operating 65°F (18 °C) to 105 °F (40.5 °C) temperature
10–95% humidity
Note: 45°F (7 °C) to 65°F (18 °C) temperature must run warm-up
cycle before disinfecting. See Operating.
Storage -20 °F (-28 °C) to 140 °F (60 °C) temperature
10–95% humidity
Note: Allow unit to reach Operating temperature before use.
Pollution Degree 2
UV-C Energy Source
Germicidal Bulbs (4) 20W UV-C Lamps
Output 254 nm UV-C Light
Chamber Components
Controller See Touchscreen Display.
Emergency Switch Located on both sides on machine, buttons turn OFF chamber
in case of emergency (re, smoke, etc.).
Tray / Reective Liner The tray / reective liner rests inside the bottom of the chamber
and are removable for easy cleaning.
Handles Can be found on either side to securely open and close both
chamber doors.
Windows The windows use glass not transparent to UV-C.
Germicidal Bulbs There are four (4) germicidal UV-C 20W bulbs.
Chamber Chamber will automatically turn o after programmed time.
Magnet Securely holds doors in closed position while running.
3

SAFETY
Definition of Symbols
Warning
• It is possible that emissions from this product may interfere with some sensitive
appliances when placed nearby or in the same circuit as those appliances. The
user should be aware of this potential and take appropriate measures to avoid
interference.
• Not all materials are UV-C safe. UV-C rays can cause physical damage to products.
If products are excessively warm when they are removed after cleaning, they may
have been damaged by the UV-C.
• Do not put humans or live animals in the chamber.
• Do not allow children in or near the chamber.
• Do not place ammable liquid(s) in chamber.
Lamps
The lamps inside emit short wave UV-C radiation. Overexposure to direct or reected
UV-C light can cause severe damage to the eyes and skin. Never look into an illuminated
UV-C lamp without proper eye protection. The chamber windows provide a safe way to
view inside chamber without the risk of UV-C expsosure.
Ozone may be formed near UV-C lamps. Excessive ozone exposure can cause eye
irritation and discomfort in the respiratory tract. Operate the BioShift®Pass-Through
UV-C Chamber in an adequately ventilated area.
Use caution handling and changing lamps. They are glass and are subject to fracturing.
They contain a small amount of mercury, a chemical known to the state of California
to cause birth defects or other reproductive harm. The mercury is contained inside the
lamp and will not be released unless the bulb is damaged. Use appropriate PPE when
handling.
The bulbs are sensitive to the oils in human skin, always handle by the plastic ends or
with gloves.
Lamp Disposal
Dispose in accordance with state and local laws.
4
RISK OF UV
EXPOSURE CAUTION BIOHAZARD

SAFETY
Features
Emergency Stop The safety switch can be found on either side of the chamber and
can be used at any time to stop the operation. Pressing EMERGENCY
STOP disconnects all power.
Open Door(s) BioShift®unit will not operate when the chamber doors
are open. The doors cannot be opened during cycle time
unless EMERGENCY STOP is pressed. Both doors cannot be
opened at the same time unless EMERGENCY STOP is pressed.
Clean Side Door Once cycle time is complete, the clean side door can be opened
once. If the dirty side door has been opened, the clean side
door will not open unless another cycle is complete. The
BioShift®chamber WILL NOT resume operation after re-closing.
Pressing the EMERGENCY STOP will open clean side door.
Start Button Illuminates blue when ready to start cycle.
Chamber The sealed chamber is meant to protect users from UV-C radiation.
Window Users are protected by glass that is not transparent to UV-C radiation.
Controller The controller has a countdown timer which allows you to check
Lamp Life, recommended after 1000 cycles, 3000 hours, or after
Dose Test failure (see Maintenance).
5
Note: If the equipment is used in a manner not specied by the manufacturer, the
protection provided by the equipment may be impaired.

INSTALLATION
The BioShift®unit comes with an attached mounting bracket. It can be installed in a
number of ways depending on the wall or door that will support them. A 30.25’’x 24.5’’
(768 x 622mm) cut-out is recommended to support the chamber when mounting.
Note: The BioShift®chamber can be installed in dry locations only (Pour emplacements secs
seulement). Product is approved for indoor use at an altitude up to 2000m.
1. Remove screws (4) on mounting bracket located on both sides of unit and set aside
for later use.
2. Using screws or nails (not provided), attach removed panels to support beams. Use
as many screws or nails needed to ensure panel is securely held to beams.
3. Using two people, carefully slide BioShift®chamber into place and secure panel to
unit using four screws removed in Step 1.
4. Plug supplied power cord into standard electrical outlet. Note: Alternate power
cords not permitted.
For small object disinfection. position tray in the center slot for optimal cleaning.
For larger, heavier objects, position tray in the bottom slot.
Removal
Always disconnect power before moving.
6

TOUCHSCREEN DISPLAY
The touchscreen display is located on the clean side of the BioShift®chamber.
Home Screen Components
(1) Disinfection Time Display
(2) Chamber Start / Stop
(3) Chamber Status
(4) Settings
(5) Maintenance
1
3
4
2
5
7

TOUCHSCREEN DISPLAY
Located under the Maintenance button.
Maintenance Screen Components
(1) View Lamp Life Remaining
(2) Reset Lamp Life
(3) View Lamp Replacement Info
(4) Run 100mJ/cm2Dose Test
(5) Run 250mJ/cm2Dose Test
(6) Run 1000mJ/cm2Dose Test
1
4
2
3
8
5
6

9
1
4
2
3
TOUCHSCREEN DISPLAY
Located under the Home screen Settings button.
Settings Screen Components
(1) View Set Lamp Cycle
(2) Set Lamp Cycle
(3) Set Sleep Time
(4) Expired Lamp Life
(5) Contact ONCE®
5
Table des matières
Autres manuels Once Équipement industriel