Omega OM-ES-020 Manuel utilisateur

OM-ES-020
Ethernet-to-Serial Device Server
Shop online at
omega.com®
e-mail: [email protected]
For latest product manuals:
omegamanual.info
QUICK START

OMEGAnet®Online Service
omega.com
Internet e-mail
Servicing North America:
U.S.A.: Omega Engineering Inc., One Omega Drive, P.O.Box 4047
ISO 9001 Certied Stamford, CT 06907-0047 USA
Toll-Free: 1-800-826-6342 TEL: (203) 359-1600
Canada: 976 Bergar, Laval (Quebec) H7L 5A1, Canada
Toll-Free: 1-800-826-6342 TEL: (514) 856-6928
For immediate technical or application assistance:
U.S.A. and Canada: Sales Service: 1-800-826-6342/1-800-TC-OMEGA®
Customer Service: 1-800-622-2378/1-800-622-BEST®
Engineering Service: 1-800-872-9436/1-800-USA-WHEN®
Mexico/ TEL: 001 (203) 359-1660 FAX: 001 (203) 359-7700
Servicing China:
China: 1698 Yi Shan Road, Unit 102, Min Hang District, Shanghai, China 201103 P.R.C.
Servicing Europe:
Benelux: Toll-Free: 0800 099 3344 TEL: +31 20 347 21 21
Czech Republic: Frystatska 184, 733 01 Karviná, Czech Republic
TEL: +420-59-6311899 FAX: +420-59-6311114
France: Toll-Free: 0805 541 038 TEL: 01 57 32 48 17
Germany/Austria: Daimlerstrasse 26, D-75392 Deckenpfronn, Germany
Toll-Free: 0800 8266342 TEL: +49 (0) 7056 9398-0
United Kingdom: OMEGA Engineering, Ltd., One Omega Drive, River Bend Technology Centre
ISO 9001 Certied Northbank, Irlam, Manchester M44 5BD United Kingdom
Toll-Free: 0800-488-488 TEL: +44 (0) 161 777-6611
It is the policy of OMEGA Engineering, Inc. to comply with all worldwide safety and EMC/EMI regulations that
apply. OMEGA is constantly pursuing certication of its products to the European New Approach Directives.
OMEGA will add the CE mark to every appropriate device upon certication.
The information contained in this document is believed to be correct, but OMEGA accepts no liability for any errors it contains,
and reserves the right to alter specications without notice.
WARNING: These products are not designed for use in, and should not be used, for human applications.

1. Box Contents Check List 3
2. Hardware 4
3. Network IP Addressing 5
4. Connecting your OM-ES-020 6
5. Installing your OM-ES-020 Device on Windows 7
6. Configuring your OM-ES-020 Device 10
7. Default Settings 11
8. Pin outs 12
9. LED information 13
For more information, please refer to Product Manual on CD
Information on Product Accreditations, Safety, and correct disposal of this product can be found on the Product
CD
Contents
2

1. Box Contents Check List
Ethernet to Serial
Device
Quick Start Guide
OM-ES-511
OM-ES-522
OM-ES-020
®
omega.com
800-DAS-IEEE (800-327-4333)
© COPYRIGHT 2013 OMEGA ENGINEERING, INC.
Utility Software for OM-ES Series
Ethernet-to-Serial Device Servers
Includes:
• Software
• User Manuals
Rev. _____
Product CD
Thank you for purchasing an OM-ES-020 Ethernet to Serial product. This
quick start guide will help you set up your OM-ES-020 device so that you
can begin experiencing the benefits of Ethernet to Serial technology.
3

4
2. Hardware
1. Screw terminal block connec-
tion
6. Reset button
(use unfolded pa-
perclip to press)
2. Wall mount screw hole 7. Ethernet port connection -
10BaseT / 100BaseTX
3. Serial Port LED 8. Status LED
4. Ethernet LED 9. DIN Rail kit holes
5.
Power Input 5-30V DC, 0.75-
1.06W Typical
10. Non-conducting polyamide
case
1
3
2
567
48
9

On connecting to the network, the device automatically checks
if it is connected to a DHCP Server. If this is the case, the DHCP
server will allocate an IP address automatically to the OM-ES-020
device.
If no DHCP Server is detected (e.g. you are using a direct cable
connection to the PC), the OM-ES-020 device will default to an
IP address of 192.168.127.254 within 60 seconds. Please ensure
the PC you’re using for configuration can communicate with the
192.168.127.xxx IP range.
3. Network IP Addressing
l
l
The OM-ES-020 device is shipped in “DHCP Mode”.
5

6
1. Connect the OM-ES-020 device to your local network or use a direct
cable connection using a standard straight-through or crossover
Ethernet cable and plugging into the Ethernet port connection.
2. Connecting to Power: Connect the power adapter or a DC power line
(5-30V) to the OM-ES-020 power terminal block or jack connection *If
using your own power supply please check input requirements on page 5 - Hardware
3. When the Status LED turns steady green (after 5-60 seconds), the
device is ready to use.
4. Connect the serial cable from your serial device to the serial port on the
OM-ES-020 device. Refer to Section 8 of this Quick Start Guide for pin
outs.
Make a note of device MAC address (on side panel, 00-0a-4f-XX-XX-XX) as
you will need it to identify the device on your network later.
4. Connecting your OM-ES-020 Device

1. Insert the CD into your PC. This should launch the Boost.LAN
Navigation Page automatically.
Note: If the navigation page does not auto load, go to Start gMy Computer gRight Click the
CD and select Explore. This will open the CD in Windows Explorer for browsing the contents of
the CD. Locate the “Setup.exe” program on the CD and double click to launch. Proceed to Step 3.
Note: If installing the software in Windows 2000 launch the "SetupW2k.exe" program on the CD.
5. Installing your OM-ES-020 Device on Windows
2. Click "Install" to launch the Boost.LAN Setup.exe
7

8
4. When installation is complete, you should see an icon labelled
Boost.LAN Manager on the desktop. Double click the link to
open the application
5. Click on the “File -> Find Devices” button in the top left hand side
of the window.
3. Follow the on screen instructions to install the Boost.LAN software.
Note: Boost.LAN software requires the Microsoft .NET framework to be
installed on your machine. If it is not already installed, the Setup.exe will
install it automatically. Please follow on screen instructions and reboot if
prompted to continue installation.
5. Installing your OM-ES-020 Device Continued...

5. Installing your OM-ES-020 Device Continued...
7. Once found, select the device and
scroll to the "Tasks" section on the
left hand panel.
6. You can find your Omega OM-ES-020 device by selecting a device and
matching it with the corresponding MAC address available on the left
hand panel.