NuEra AIRVOLUTION Manuel utilisateur

© 2015 MacroAir Technologies Toll Free: 866 668 3247 Fax: 909 890 2313 www.macroairfans.com Rev. Date 032315 1

2 © 2015 MacroAir Technologies 1-800-347-9575 - www.nueraheat.com

© 2015 MacroAir Technologies 1-800-347-9575 - www.nueraheat.com 3
TABLE OF CONTENTS
Caution & Safety .........................................................................................................................................................................................4
Fan Placement - General Information.......................................................................................................................................................6
Fan Clearance & Placement ......................................................................................................................................................................7
Fan Dimensions ..........................................................................................................................................................................................8
Fan Components ........................................................................................................................................................................................9
Universal Mount & Components .............................................................................................................................................................10
Fan Mounting ............................................................................................................................................................................................11
Span Mount ...............................................................................................................................................................................................12
Truss Mount ..............................................................................................................................................................................................13
Installation Overview - I-beam/Purlin .....................................................................................................................................................14
I-beam/Purlin Universal Mount ...............................................................................................................................................................15
Installation Overview - Glulam .................................................................................................................................................................17
Glulam Universal Mount ..........................................................................................................................................................................18
Electrical & Safety Cable Installation ......................................................................................................................................................21
Control Panel Overview ............................................................................................................................................................................22
Control Panel Schematics .......................................................................................................................................................................23
Touchpad Remote User Interface ............................................................................................................................................................24
Touchpad Remote Installation .................................................................................................................................................................25
Touchpad Remote LCD Display ................................................................................................................................................................26
Touchpad Remote Enclosure ...................................................................................................................................................................27
Guy Wire Installation ................................................................................................................................................................................29
Blade Installation .....................................................................................................................................................................................33
Technical Support .....................................................................................................................................................................................36
Warranty Information ...............................................................................................................................................................................37

4 © 2015 MacroAir Technologies 1-800-347-9575 - www.nueraheat.com
CAUTION & SAFETY
READ THE ENTIRE MANUAL BEFORE OPERATING THE FAN. Ensure that all safety practices and instructions are followed during the installation, operation and servicing of the fan. Failure to
apply these safety practices could result in death or serious injury. If you do not understand the instructions please call our Technical department for guidance.
The fan installation should follow the recommendations outlined in this manual. MacroAir is not responsible for any injury or damage to people or property as a result of not complying with the
recommendations outlined in this manual.
IMPROPER ELECTRICAL INSTALLATION CAN CAUSE DAMAGE TO THE FAN AND INTERFERE WITH OTHER ELECTRONIC EQUIPMENT. IN ADDITION TO STANDARD ELECTRICAL SAFETY
CONSIDERATIONS, PLEASE OBSERVE THE FOLLOWING:
• THE WIRING FROM THE CONTROL PANEL TO THE FAN MOTOR MUST BE MACROAIR-SUPPLIED SHEILDED CABLE.
• SEPARATE INCOMING POWER AND MOTOR CONTROL CABLES BY A MINIMUM OF (6) INCHES.
• RUN WIRING FOR EACH FAN SEPARATELY.
• DO NOT ATTEMPT TO CONTROL MULTIPLE FANS WITH ONE CONTROL PANEL.
• ALWAYS GROUND PROPERLY. CONNECT THE SUPPLIED CABLE GLANDS TO EACH END OF THE MOTOR CONTROL CABLE AND TIGHTEN THEM SECURELY AT BOTH THE FAN MOTOR
AND CONTROL PANEL ENDS. CONNECT THE GROUND BAR IN THE CONTROL PANEL TO GROUND AT THE MAIN BREAKER BOX.
• PLEASE REFER TO THE INSTALLATION INSTRUCTIONS FOR MORE INFORMATION.
All fan controls should only be installed by qualified technicians familiar with the requirements of the NEC and local codes. Refer to appropriate portions of this manual for other important
requirements. Failure to follow these guidelines will void the manufacturer’s warranty.
NOTICE:
All electrical controls are configured at the factory and are ready to use. No user adjustments are available. Follow the included wiring schematics and installation instructions when installing
this device to ensure proper operation. Do not make any changes to any part of the motor control panel without first consulting MacroAir.
Installation is to be in accordance with the national electrical code, ANSI/NFPA 70-1999 and local codes.
HAZARD OF ELECTRIC SHOCK, EXPLOSION, OR ARC FLASH
Read and understand this manual before installing or operating
a fan unit. Installation, adjustment, repair, maintenance must be
performed by qualified personnel.
The user is responsible for compliance with all international and
national electrical code requirements with respect to grounding of
all equipment.
Many of the parts of this unit operate at line voltage. DO NOT
TOUCH.
Install all covers before applying power or starting and stopping
the unit.
DAMAGED EQUIPMENT
Do not operate or install any fans or fan accessories that appear to be damaged.
Failure to follow this instruction can result in death, serious injury, or equipment damage.
MAINTENANCE AND SERVICE:
If the fan does not operate properly using the procedures in this manual, BE CERTAIN TO REMOVE ALL POWER TO THE
UNIT and contact our technical department for futher assistance.
Keep all body parts clear of moving part at all times.
All electrical troubleshooting and repair must be done by a qualified technician and meet all applicable codes.

© 2015 MacroAir Technologies 1-800-347-9575 - www.nueraheat.com 5
CAUTION & SAFETY
Key Safety System Components
MacroAir fans are engineered with key safety features to prevent pieces of the fan from falling in the unlikely event of a catastrophic failure. Used together, these
systems and devices provide comprehensive protection of people, equipment and property. Follow the detailed instructions precisely when installing fans, including
the following:
Install safety cable on EVERY fan. Install guy wires on every fan, unless otherwise specified. Properly installing the guy wires will keep the fan stable in case of
earthquake or in “outdoor” installations where high wind conditions may occur. The safety cable, if installed per MacroAir specifications, will prevent the fan from
falling in the unlikely event that the mounting system should fail. A MacroAir fan should never be run without a properly installed safety cable, which is supplied with
every fan along with all required hardware. You must install a safety cable for the warranty to be in effect.
Install the complete set of extended blade safety links, which connect each blade to the adjacent blades and reinforce the area between the mounting holes. This is
an important precautionary measure which will help prevent a blade from falling should one break off at the hub for any reason.
Mark the Floor to Alert Personnel
When mounting a fan in an area where materials may be elevated into its path, MacroAir recommends marking or painting the floor with a large crosshatched circle
to alert personnel of the overhead location of fans.
Weight Considerations
We recommend that a building structure be capable of holding approximately twice the stated hanging weight of the fan. If there is some doubt of this, a professional
contractor or architect should perform a thorough evaluation of the building prior to purchasing the fans. MacroAir provides guidelines for mounting fans; however,
it is the sole responsibility of the building owner and installer to ensure the safety of the mounting system, that the building structure is sound and that the
installation complies with all federal, state, and local codes.
Torque
The maximum torque (twisting force) that must be handled by the mounting system, including the building structure, occurs at fan startup. For a 24 foot fan,
maximum potential starting torque is 300 Ft-Lbs. When standard electrical controls are installed, the fan will never begin to approach this maximum because the
standard variable-speed control system uses the soft-start technology. However, should the soft-start fail, or when a fan is installed as a single-speed model without
the variable speed control system (rare), full torque might be applied to the mounting system, so it is important that it be adequate to withstand 300 Ft-Lbs torque.
Check Federal, State, and Local Codes
Check all relevant codes to make sure that all product certifications, product listings, and building regulations are met. Code compliance is the responsibility of the
installer.

6 © 2015 MacroAir Technologies 1-800-347-9575 - www.nueraheat.com
FAN PLACEMENT - GENERAL INFORMATION
Sprinkler Systems and Fan Placement
In any installation where fire sprinklers are in place, do not interfere with their correct operation. Fans should be located no less than 3 feet
below a sprinkler, and placed central to each sprinkler quadrant. Our standard variable-speed control system can be connected to a fire
suppression control system, which will emergency-stop fans in case of fire. Prior to installing fans, review all codes applicable to sprinkler
systems and fans to ensure code compliance. Refer to the wiring diagrams packaged inside the control panel for proper installation. If further
advice is needed, you may contact our support staff. However, it is your sole responsibility to see that the installation is completed to code and
that it is correct.
Other Information on Placement and Spacing
If possible, avoid mounting fans directly below lights or skylights to avoid any strobe effect caused by moving blades. Note, a large fan, 20 – 24
feet in diameter, performs best at 20 to 30 feet above the floor, but acceptable performance has been demonstrated as low as 10 feet and as
high as 50 feet.
If the building has a mezzanine, fans should be mounted so a person can not reach a fan in any way from the upper level/deck. Make certain
that fans are positioned to that the blade tips are at least 3 feet away from any area where a person may be able to extend outward to reach
them.

© 2015 MacroAir Technologies 1-800-347-9575 - www.nueraheat.com 7
FAN CLEARANCE & PLACEMENT
Slope (in) 2/12 4/12 6/12 8/12 10/12
Roof Angle 9.5o18.4o26.6o33.7o39.8o
Diameter Recommended Extension Length Clearance
Radius
8 feet N/A N/A 1 1 2 7’’
10 feet N/A 1 1 2 3 9’’
12 feet N/A 1 2 3 4 11’’
14 feet 1 2 3 4 5 13’’
16 feet 1 3 4 5 7 14’’
18 feet 2 3 5 6 8 16’’
20 feet 2 4 5 7 9 18’’
24 feet 3 5 7 9 11 22’’
WARNING: FANS ARE NOT MEANT TO BE OPERATED IN WINDY CONDITIONS.
The minimum distance of a fan to a wall or similar obstruction should be no less than 1.5 times the diameter of the fan.
The goal of this diagram is to determine the proper extension length to maintain a minimum blade clearance of 15% of the fan’s diameter. The extension
lengths above are minimum recommendations only, based solely on roof pitch and fan diameter. Other factors must be evaluated when determining extension
requirements. In addition, MacroAir strongly recommends that the fan blades must be a minimum of 10 feet (3.05 meters) above the floor. Contact our
technical department for assistance with fan placement and extension selection (technical support contact information can be found on page 36).

8 © 2015 MacroAir Technologies 1-800-347-9575 - www.nueraheat.com
FAN DIMENSIONS
Dimensions listed above are applicable to all AirVolution and AirSpan fans.

© 2015 MacroAir Technologies 1-800-347-9575 - www.nueraheat.com 9
FAN COMPONENTS
Blade
Safety Retainer Link
Fan Unit
Blade End Cap
Blade Strut

10 © 2015 MacroAir Technologies 1-800-347-9575 - www.nueraheat.com
Universal Mount
Universal Mount
Extension
Guy Wire Kit
UNIVERSAL MOUNT & COMPONENTS
Ce manuel convient aux modèles suivants
1
Table des matières
Autres manuels NuEra Ventilateur