10
10) Oncetheheaterhasignitedandhasbeguntorun
continuously,locatetheManifoldadjustmentbuttons
onthecircuitboardlocatedintherightsideoftheunit
(Figure9).
11) Pressandholdthemaximumpressuresetbutton.
Verifyfromthebelowtablethattheappropriate
pressureisreadfromthemanometer.Ifthepressure
needsadjustment,usetheManifoldpressureincrease
anddecreasebuttonstoadjusttothecorrectpressure,
whilecontinuingtoholddownthemaximumpressure
setbutton.
12) Pressandholdtheminimumpressuresetbutton.
Verifyfromthetablesbelowthattheappropriate
pressureisreadfromthemanometer.Ifthepressure
needsadjustment,usetheManifoldpressureincrease
anddecreasebuttonstoadjusttothecorrectpressure,
whilecontinuingtoholddowntheminimumpressure
setbutton.
ManifoldGasPressureMaximumandMinimumValues
SettingListforManifoldPressuresNR83DVC(GQ‐2457WS‐FFAUS)
SettinglistforGasManifoldpressure(NR83‐DVC)
ManifoldPressureforNR83‐DVC(inchH2O)Coveroff
Dip7=OFFDip8=OFFDip7=ONDip8=OFFDip7=OFFDip8=ONDip7=ONDip8=ON
Ventlengthadjustment
MinimumLengthShortLengthLongLengthMaximumLength
NoVenting
Gastype/VentlengthMax.valueMin.valueMax.valueMin.valueMax.valueMin.valueMax.valueMin.valueMax.valueMin.value
NG/Minlength2.571.002.531.002.490.962.490.96
(Verticaltermination)*(2.53)(0.97)(2.46)(0.95)(2.46)(0.95)(2.40)(0.93)
NG/Maxlength2.531.002.490.962.490.962.490.96
(Verticaltermination)*(2.46)(0.95)(2.46)(0.95)(2.40)(0.93)(2.36)(0.92)
2.651.04
LP/Minlength3.731.363.651.363.611.323.571.32
(Verticaltermination)*(3.61)(1.30)(3.53)(1.30)(3.53)(1.30)(3.49)(1.28)
LP/Maxlength3.651.363.611.323.571.323.571.32
(Verticaltermination)*(3.53)(1.30)(3.53)(1.30)(3.49)(1.28)(3.45)(1.28)
3.81
1.41
*Usethesesettingswhentheunitterminatesusingtheverticalraincap
ManifoldPressure(inchH2O)CoverOff
ModelNameGasTypeSupplyPressure
(inchH2O)MaxValueMinValue
NG 7.93.460.87N‐0931M/NR111‐SV,
N‐0931M‐ASME/NC250‐SV‐ASMELP11.03.650.94
NG7.93.150.75
N‐0931M‐OD/NR111‐ODLP11.04.370.98
NG 7.93.450.94N‐0931M‐DV/NR111‐DV,
N‐0931M‐DV‐ASME/NC250‐DV‐ASMELP11.04.020.91
NG7.92.851.00
NR83OD(GQ‐2457WSUS)LP11.04.251.40
NG7.9NR83‐DVC/NR83DVC(GQ‐2457WS‐
FFAUS)LP11.0
Refertothe“SettinglistforgasManifoldpressure
(GQ‐2457WS‐FFAUSandNR83‐DVC)”below
ManifoldPressure(inchH2O)Coveroff
Dip7=OFFDip8=OFFDip7=ONDip8=OFFDip7=OFFDip8=ONDip7=ONDip8=ONVentlength
adjustmentMinimumShortLongMaximum
GastypeMax.valueMinvalueMax.valueMinvalueMax.valueMinvalueMax.valueMinvalue
NG2.750.902.700.852.700.852.650.80
LP3.851.253.801.253.751.203.701.20
FIGURE9