HYDRAULIC Anchor Applicator Model BAAM
Section H-4 MAR/2005 (49454100)
EMERGENCY PUMP USE – MANUAL
PUMP
For All Components Except Brakes:
1. Turn ignition switch to the OFF
position.
2. Attach one end of the hose (found in
the toolbox) to hand pump and the
other end of the hose to the quick
disconnect at the brake lock valve.
3. Pressurize the hand pump by moving
the hand valve lever (lever with round
knob) on the pump toward the pump.
4. Continue pumping until all components
are raised to the point where you can
insert lockups. Insert lockup pins.
5. Continue on to lock off brakes for
towing.
For the Hydraulic Brakes:
8. With the machine on level track,
chock ALL wheels to prevent
movement.
9. Close the ball valve at the brake valve
stack (see photo to right) and lock in
the CLOSED position. (CLOSED is
perpendicular to the hose line, OPEN
is parallel to the hose line.)
10. Attach one end of the hose (found in
the toolbox) to the electric pump.
Attach the other end of the hose to
the quick disconnect at the brake
valve.
11. Turn on the emergency pump at the
control box.
12. Once the hydraulic brake cylinder has
collapsed and has released the
brakes, install the lockpins as shown.
13. Release hand pump pressure by
moving the hand valve lever on the
pump away from the pump, , remove
hose and wheel chocks, and perform
towing as required.
14. Once you have towed to a site to
perform maintenance on the hydraulic
system, open the ball valve (closed
under step 9) and lock in the OPEN
position.
Tools And Equipment Required For These
Procedures:
¾-Inch Combination Wrench
Company Furnished Padlock
Hand Pump Hose (Found In Toolbox)
Lockpins (Found In Toolbox)