Norac UC4+ Manuel utilisateur

Generic (Fixed Boom)
Installation Manual
Spray Height Controller
Improving the competitiveness of Industry and
Agriculture through Precision Measurement

Printed in Canada
Copyright ©2005-08 by NORAC Systems International Inc.
Reorder P/N: UC4+BC+GN2-INST Rev D (Generic Fixed Boom)
NOTICE
NORAC Systems International Inc. reserves the right to improve products and their specifications without notice and without the requirement to update
products sold previously. Every effort has been made to ensure the accuracy of the information contained in this manual. The technical information in
this manual was reviewed at the time of approval for publication.

TABLE OF CONTENTS
1INTRODUCTION ..................................................................................................................................................1
2GENERAL SYSTEM DESCRIPTION ..................................................................................................................2
3PARTS LISTS ......................................................................................................................................................3
4INSTALLATION PROCEDURE ...........................................................................................................................5
4.1 WING SENSOR INSTALLATION ........................................................................................................................5
4.2 ELECTRICAL INSTALLATION............................................................................................................................7
4.2.1 Control Panel 7
4.2.2 Inside Cab 8
4.2.3 Outside Cab 9
4.2.4 Electrically Teed Installation 10
4.3 COMPLETING THE INSTALLATION ..................................................................................................................12
5CALIBRATING THE SLANT VALVE ................................................................................................................13
5.1 OVERVIEW...................................................................................................................................................13
5.2 VALVE DEADZONE TEST ..............................................................................................................................14
5.3 VALVE GAIN TEST .......................................................................................................................................15
6ELECTRICAL REFERENCE – CABLE DRAWINGS........................................................................................16
6.1 ITEM C02: 44668 –SENSOR BRANCH CABLE...............................................................................................16
6.2 ITEM C10: 44650-35/39 –POWER CABLE GENERIC .....................................................................................17
6.3 ITEM C11: 44651-03 –EXTENSION CABLE VALVE GENERIC .........................................................................18
6.4 ITEM C12A: 44658-35 –GENERIC INTERFACE CABLE ..................................................................................19
6.5 ITEM C12B: 44658-36 –GENERIC WING INTERFACE CABLE.........................................................................20
6.6 ITEM C14: 44658-28 –INTERFACE CABLE POWER PIGTAIL ..........................................................................21
6.7 ITEM C15: 44658-31 –INTERFACE CABLE HAND CONTROL PIGTAIL .............................................................22
6.8 ITEM C17: 44658-42 –GENERIC INTERFACE ROLL CABLE ...........................................................................23

1
1 INTRODUCTION
Congratulations on your purchase of the NORAC UC4+ Spray Height Controller. This system is
manufactured with top quality components and is engineered using the latest technology to provide
operating features and reliability unmatched for years to come.
When properly used the system can provide protection from sprayer boom damage, improve sprayer
efficiency, and ensure chemicals are applied correctly.
Please take the time to read this manual completely before attempting to install the system. A thorough
understanding of this manual will ensure that you receive the maximum benefit from the system.
YOUR INPUT CAN HELP MAKE US BETTER! If you find issues or have suggestions regarding
the parts list or the installation procedure, please don’t hesitate to contact us via the information
given below:
Phone: 1 800 667 3921 Canada (Toll Free)
1 866 306 6722 United States (Toll Free)
(+33) 06 03 87 80 78 Europe
(+1) 306 664 6711 All other regions
Web: www.norac.ca

2
2 GENERAL SYSTEM DESCRIPTION
Figure 1 depicts the general system layout of the UC4+ Spray Height Control system.
Figure 1 – System Components and General Location
NOTICE:
Every effort has been made to ensure the
accuracy of the information contained in this
manual. All parts supplied are selected specially
to fit the sprayer to facilitate a complete
installation. However, NORAC cannot
guarantee all parts fit as intended due to the
variations of the sprayer by the manufacturer.
Please read this manual in its entirety before
attempting installation.
ATTENTION:
When installing the UC4+ Spray Height Control
system please be aware that at a point in the
installation your sprayer booms will be
inoperative until the installation is complete.
Any installation procedure requiring boom
movement will need to be done first. Once the
hydraulics have been disconnected you must
complete the electrical installation before the
booms become operative.

3
3 PARTS LISTS
The parts that come with your UC4+ Sprayer Boom System are listed in Table 1. The item number on
the left side of this table references each part.
Please ensure that all parts in your kit are present before proceeding with your installation.
Table 1 – Generic Fixed Boom Spray Height Control System Parts
Item Part Number Name Quantity
B05 44706-01 KIT CABLE TIE BLACK 10 PCS 21 IN 150 PCS 7.5 IN 1
B13 44728 MOUNTING BRACKET COMPLETE UC4 BREAKAWAY EXTENDED 2
C02 44668 CABLE UC3 SENSOR BRANCH 1 AMP RECEPT 3 AMP PLUG BC 1
E01 4461BC+ UC4 PLUS BOOM CONTROL PANEL 1
E02 44631 UC4 ULTRASOUND SENSOR 2
M01 4476BC+MAN7 OPERATOR MANUAL UC4+ SPRAY HEIGHT CONTROL (FIXED BOOM) 1
M02 UC4+BC+GN2-INST MANUAL INSTALLATION UC4+ GENERIC FIXED BOOM 1
M03 UC4+BC+GN2-INSTE MANUAL INSTALLATION UC4+ END USER GENERIC FIXED BOOM 1
Generic interface cables are shown in this manual. They are available separately from
NORAC. Please see UC4-BC-AN-CBL, UC4 Generic Cable Ordering Guide, for more
information.

4
The parts that come with your UC4+ Spray Height Control system are shown below in their general
installation configuration.
Figure 2 – UC4+ Spray Height Control Components

5
4 INSTALLATION PROCEDURE
4.1 WING SENSOR INSTALLATION
1. Assemble the Breakaway Sensor Mounting
Brackets (B11) as show in Figure 3 and
Figure 4.
Figure 3 – Breakaway Sensor Bracket
Exploded View
Figure 4 – Breakaway Sensor Mounting
Bracket Assembly
To assemble the breakaway sensor bracket:
a) Assemble the bolt and nut into the collar.
b) Grease the bottom edge of the collar and
the angled tube of the base.
c) Place the collar onto the angled tube of
the mounting base.
d) Install the spring between the collar and
the upper ring of the base.
e) Insert tube through assembly and tighten
the collar
2. Mount the sensor bracket onto the boom.
If possible, mount the sensor brackets
while the booms are in their folded
position to ensure that they will not
interfere with anything when the boom
is folded for transport.
3. The sensor mounting brackets can be
installed with the mounting base behind
(Figure 7) or in front of the tube (Figure 5).
It is advised to avoid mounting the
sensor bracket to a breakaway portion
of the boom because a breakaway
action can cause the UC4+ Spray
Height Control system to force a boom
close to the ground.
4. Mount the NORAC UC4+ ultrasonic sensor
(E02) into the sensor brackets. The sensors
should be oriented forward (ahead) of the
boom (see Figure 5 and Figure 7).
When installing the UC4+ sensors
(E02), start with the smallest serial
number on the left hand side
proceeding to the largest serial number
on the right hand side.

6
5. Sensor cables should run through the
mounting bracket tube and then behind the
member the bracket is mounted onto. Cable-
tie the connector in place. The cable must
not be allowed to hang below the boom
(Figure 5).
Figure 5 – Another Acceptable Mounting
Avoid mounting sensors in locations
where they may read from parts of the
boom as shown in Figure 6.
Figure 6 – Poor Mounting
(Sensor Reading off Boom)
General mounting rules for UC4+
ultrasonic wing sensors:
a) In its lowest position, the sensor mouth
must be 9 inches or more from the
ground.
b) The bottom of the sensor must be at least
9 inches in front of the spray nozzles.
c) The bottom of the sensor must be at least
9 inches above the spray nozzles.
d) Ensure that there are no obstructions
within a 12-inch diameter circle projected
directly below the center of the sensor.
e) The sensor should be approximately
vertical at normal operating heights.
Figure 7 – Sensor Mounting Guidelines
A
B
B
D
C
Ultrasonic
Acoustic Cone

7
ROP
4.2 ELECTRICAL INSTALLATION
4.2.1 Control Panel
1. Install the UC4+ Control Panel (E01) in the
cab of the sprayer. Mount the panel where it
will be clearly visible and within easy reach
of the operator.
A good spot to mount the UC4+ control
panel is on the right hand side of the cab to
the Roll Over Protection Bar (ROP). Four
pilot holes for the screws provided need to be
drilled to facilitate the control panel
mounting.
Another option is to purchase an adapter for
the flexible panel mount that has a 3/8" NC
threaded stud on the end to bolt through an
existing mount. You can find these at your
local outdoor store as a RAM mount part
number RAM-B-236. (See
http://www.ram-mount.com/)
Figure 8 – Control Panel Mounting
ROP
Autres manuels pour UC4+
41
Table des matières