Cautions and Safety Notice
ILLUSTRATIONS: “Cautions and Safety Notice”, “Cautions for Setting Antenna”as well as illustration on Product use various illustrations
so that customers may operate safely and properly, and to prevent from damage on other parties life and properties.
Each illustration and its meaning are below. Please carefully understand before reading the text of instruction manuals.
mark draws your attention (including remarks and alarms). Concrete remarks and alarms are
illustrated in the picture.
mark notice you of prohibited deed. Concrete details of prohibited deeds are illustrated.
mark notice you of instruction and compulsion on your deed. Concrete instructions are illustrated.
ALARM This remark shows the possibility of injury on human and physical damage if you neglect or
wrong handling inspite of this remark.
Thunder is rumbling, please do not touch antenna and cable. The action cause an electrocute.
ATTENTION This remark shows the possibility of injury on human and physical damage if you
neglect or wrong handling inspite of this remark.
After storm or hurricane, a malfunction or loose fitting of
antenna setting may happen. Leave such situations cause
damage and human injury. Please consult with the
professional engineer or service company.
When pull off power plug, please hold the body of power
plug and take it (power plug or AC adaptor) off.
Pull off power cable only may cause damage of cable which
may cause misfire or electrocute.
Do not hang laundries on antenna or metal fittings which
cause injury due to fall down or broken accident of
antenna.
Do not use power plug with wet hands which may cause
electrocute.
Do not use at place where high mositure and dusty area, and
where oily smoke and hot steamy place, and where high
temperature area (cooking or humidifier).
Do not use voltage over the designated power.
Do not use AC adaptor which is not specified by manufacturer.
Failing may cause misfire and electrocute.
Antenna should be set at empty pass and at higher place
above 2m so that it does not hurt human head.
Please pay attention that power insertion and AC adaptor
shoud not be wet, failing which may cause misfire and electrocute.
Please set
antenna
separate
from electric
pole and
cable as
possible as
you can
Please operate antenna
setting after securing
foothhold.
Please do not drop
tools while setting
antenna from roof.
While setting antenna, please avoid
the place under big tree and tall
building and choose where visibility
is clear ahead.
ATTENTION
Antenna setting should be
separated form the busy traffic
road, electric sign-board and
high voltage cable.
When setting antenna, please find
the best direction, area and height
where you can get good picture.
Antenna coaxial cable should not
be contacted with roof and rain
gutter.
How to connect cables.
Connect co-axial cable with terminal.
Caution Please pay attention that the short circuit may not occure between core cable and cover weaving cable.
Please pay attention that when damage on core and cover cables, do not hurt yourself with the cable.
How to use the waterproof
cap.
Cap shall be cut to the thickness
of coaxial cable.
Cut off by scissors
Processing cable
F type connector is sold separately.
Tools needed
Cutter, knife, scissors, nippers, pliers.
Parts Name Aluminum Ring
Core cable
Cover Weaving
cable
connector
Insulator
Aluminium
foil
F type
Outer Cover Coat
Waterproof cap should be
pierced with coaxial cable
in advance
the cover of the coaxial cable to
be peeled off by cutter or knife
as shown in the dotted line.
waterproof cap
Peel off the outer cover and pierce the aluminium
ring.
Cut off cover weavimg cable about 2mm depth
from the outer cover.
Turn over the weaving cable.
Cut off insulator and aluminium foil about 3mm
length.
F type connector should be inserted between
aluminium foil and weaving cable, and press
to crash the aluminium ring by tool.
Core cable shall be 1~2mm naked and cut diagonally.
Please note the longer core cable may
damage the contact terminal.
Core cable which is cut diagonally may be easily insterted
POINT
Core cable outside diameter should be less than 1.5m.
In case the cable is thicker than 1.5mm, please make use of pin connector.
(*When substitute the coaxial cable, please use the same outer diameter cable.)
How to connect the coaxial cable
Outdoor Please connect the coaxial cable to the output terminal by spanner. Tighten torque strengh should be around
2.0N/m (20kgf/cm). After fastening , press insert of the waterproof cap into the dead end.
In case of area where salty damage and plenty rainfall are expected, we recommend to use another supporting
waterproof tape and wind up by another vinyl tape before setting the cap.
Waterproof cap Supporting
waterproof tap
(sold separately)
Vinyl tape
(Sold separately)
Indoor
Setting By Stand
Connecting cable to
antenna body should use
L type push-plug, or L
type connector.
L type push-plug,
or Ltype connector
Setting to Indoor Wall
The coaxial cable should be connected with output terminal and to be tight fasten by spanner.
Tightening torque strength should be about 2.0N/m (20 kgf/cm).
ATTENTION