4. Operation
On/Off
Power on External 12V power supply
Turn on When the power is turned on, the indicator flashes once.
Restore to factory setting Press and hold the function key for 5 seconds till green indicator flashes for 20 times.
Power off Remove power
Note:
1. Five seconds after power on, the device will be in engineering test mode.
2. Remove and supply the power; the device is at off state by default. Need to be turned on to use.
3. On/off interval is suggested to be about 10 seconds to avoid the interference of capacitor inductance and other
energy storage components.
Network Joining
Never joined the network
(Or at factory setting )
Turn on the device to search the network.
The green indicator stays on for 5 seconds: success
The green indicator remains off: fail
Had joined the network
(Not at factory setting.)
Turn on the device to search the previous network.
The green indicator stays on for 5 seconds: success
The green indicator remains off: fail
Fail to join the network
(when the device is on)
First two mins: wake up every 15 seconds to send request.
After two mins: enter sleeping mode and wake up every 15 minutes to send request.
Note: Suggest to remove batteries if the device is not used to save power.
Suggest to check the device verification information on the gateway
or consult your platform server provider.
Function Key
Press and hold for 5 seconds Restore to factory setting / Turn off
The green indicator flashes for 20 times: success
The green indicator remains off: fail
Press once The device is in the network: Send recently received data (SensorRawCmdIndication),87(CmdID)+ReceiveData
The device is not in the network: the green indicator remains off
Serial Transmission Rate Configuration
Serial Transmission Rate Default Value 9600
Configuration Method Deliver instructions through LORANWAN
Serial Transmission Rate Option
;
;
;
03 Baudrate = 28800;04 Baudrate = 19200;05 Baudrate = 9600;
;
;
5. Data Report
The device will send a version package Report immediately after powering on the device.
The device has no operation until any configuration is done.
The device sends a down-link command configuration with LoRaWAN for the data that needs to be sent through the RS485 and sends the data
received by the RS485 to the gateway.
The device sends a down-link command with LoRaWAN to send the data periodically.
When the RS485 interface of the R718PC receives the serial port data sent from the RS485 device connected to it, it will actively report the
received data to the gateway in the format of 87+ReceiveData.