NEO Spring Manuel utilisateur

User’s Manual
Purity In Each Drop
Latest RO+UV technology
Now at your home

Table of Contents
1 SafetyInformaon .....................................................................................................1
2 WaterPuricaonProcess.........................................................................................2
3 ReverseOsmosisProcess...........................................................................................3
4 UVProcess .................................................................................................................3
5 Specicaons:NeoSpring .........................................................................................4
6 Specicaons:NeoPura ............................................................................................5
7 Installaon .................................................................................................................6
8 PackingList................................................................................................................6
9 FilterReplacementCycle ...........................................................................................7
10 ProblemAnalysis.....................................................................................................7-8
11 WarrantyCard...........................................................................................................9
12 Terms&CondionsofWarranty .............................................................................10

Safety Information
1

Water Purification Process
Step 1 : PP Filter
PPlterhasthefunconstoremovetheoatersuchassandiron,rust,copperrustor
visibleimpuries.
Step 2 : Pre-carbon Filter
Pre-carbonFilterwhichcanremovechlorine,organic,compounds,color,odourand
oangparcles.
Step 3 : Sediment Filter
Sedimentlterhasthefunconstoremovetheoatersuchassandiron,rust,copper
rustorvisibleimpuries.
Step 4 : TFC RO Membrane
ROmembranelterremoveswatercontaminantssuchasheavymetals,waterborne
micro-organismsandharmfulorganicchemicalsetc.
Step 5 : TDS Controller
IthelpsmaintainminimumTDSleveltobepresentindrinkingwater
Step 6 : Post Carbon/Mineral Cartridge
PostCarbonImprovesthetasteofpuriedwater.
MineralCartridgeincreasesthemineralcontentinthewateraddinghealthbenets.
Step 7 : Ultra Violet
U.V.hasthefuncontoprovideBacterialDisinfeconinwater
2

Reverse Osmosis Process
UV Process
TheReverseOsmosisprocess,alsoknownas
hyperltraon,isthenestltraonprocess
knownlldate.Theprocessensuresremoval
ofparclesassmallasionsfromasoluon.
Reverse Osmosis uses a semi-permeable
membrane to remove salts from potable/
brackish water. In Reverse Osmosis, water
pressure applied to the concentrated side
forces the process of osmosis into reverse.
Under enough pressure, treated water is
“squeezed” through the membrane from
the concentrated side to the diluted side.
Saltsdissolvedin wateraschargedionsare
repelledbytheROmembrane.Therejected
impuriesontheconcentratedsideofthemembranearewashedawayinastreamof
wastewaterandthusdonotgetaccumulatedasinatradionallter.
TheUVlighthasshorterwavelength(higherenergy)thanthevisiblelight.Itiscalled
ultra-violetbecauseitisjustbeyondvioletlightinthelightspectrum.Technically,the
ultra-violet light is dened to be any wavelength of light, which is shorter than 400
nanometer.
UVrays,whichpenetrate intothemicro-organisms, areabsorbedbythe DNA of the
pathogen in the water. The DNA is altered in such a way that the pathogen cannot
reproduceitself.Thus,itisessenallykilledandcannotcauseinfecon.Thisprocessof
DNAmodicaoniscalledinacvaon.
3

Product Water Puricaon Device
Model Neo Spring
PuriedMethod Reverse Osmosis + Ultra Violet + Mineral Cartridge*
FilterSize/FilterLife PP Filter 11”/6 month
Pre-Carbon 11“/12 month
Sediment 11”/12 month
Membrane 11”/ 24 month (1,900 gal)
Post Carbon 11”/ 12 month
UV 8’’/24 month(10000 hr)
PowerConsumpon with booster pump AC100-240V DC24V(1.8 Lpm)
Dimensions(WidthxHeightxDepth) 407 X 520 X 190
NetWeight 12 kg
ProduconCapacity 10 Ltr/hr (2.6 gal/hr)
TankCapacity 10 Ltr
Water Temperature 5-45°C
MAXTDS <1000ppm
RemovalRate >90-96%
InletWaterPressure 0.15 ~ 0.35 Mpa
LowPressureSeng 0.05 Mpa
MainConguraon 7 Stage + Pump
*Oponal
Specification
4

Product Water Puricaon Device
Model Neo Pura
PuriedMethod Reverse Osmosis + Ultra Violet* + Mineral Cartridge*
FilterSize/FilterLife PP Filter 11”/6 month
Pre-Carbon 11“/12 month
Sediment 11”/12 month
Membrane 11”/ 24 month (1,900 gal)
Post Carbon 11”/ 12 month
UV 8’’/24 month (10000 hr)
PowerConsumpon with booster pump AC100-240V DC24V(1.8 Lpm)
Dimensions(WidthxHeightxDepth) 330 X 432 X 267
NetWeight 11 kg
ProduconCapacity 10 Ltr/hr (2.6 gal/hr)
TankCapacity 8 Ltr
Water Temperature 5-45°C
MAXTDS <1000ppm
RemovalRate >90-96%
InletWaterPressure 0.15 ~ 0.35 Mpa
LowPressureSeng 0.05 Mpa
MainConguraon 7 Stage + Pump
*Oponal
Specification
5

Installation
1.Closemainwatersupplyvalvetoseparatethefaucet.
2.WindtheTeontapeontheadaptorandtittothepipe.
Do not turn the water pipe.
3.Connectthefaucetwiththeadaptor.
Shall install the adaptor with connector on the cold water
pipe.
4.Connect1/4inchwhitetubingwiththeconnectoronthe
adaptor.
Flush water through each lter at least 5 minutes before
Connecon.
Packing List
RO machine 1set
TFC RO membrane 1piece
Accessory BallValve,GateValve,Spanner,TeonTape
Tubing (1/4”) 5 m
Warranty Card 1nos.
Manual 1piece
Pre Filter Housing Set 1piece
6

Filter Replacement
Filter Replacement Cycle
Thelterreplacementcyclemenonedbelowisnotthelterqualitywarrantyperiod
buttheexpectedcycle(life)thattheltershowsitsoriginalperformance.Therefore,
thelterchangecyclemaybereducedfortheareawithpoorwaterqualityormore
applicaons.
Filter name Usable Period
PPFilter 12Months
Pre-carbonlter 12months
Sedimentlter 12months
PostCarbon/MineralCartridge 12months
MembraneFilter(RO) 24months
UltraVoilet 24months
7
Problem Analysis
Anyproblems,pleasedocontactthelocalsellertoobtainprofessionalsoluons,the
followinganalysisareforrepairer’sreference.
PROBLEM PROBABLE CAUSE SOLUTION
Pumpnotworking&
noproduconofwater
(rstmakesurethe
adapterplugisok&the
electricityison)
1.Sourcewaterpressureistoolowto
shutothelowpressureswitch.
2.LPS&HPSoutofworkorloose
connecon.
3.Powerswitchproblem
4.Pumpproblem.
1.Enhancesourcewater
pressure.
2.Repairorreplaceit
3.Repairorreplaceit
4.Repairorreplaceit
Leakagefromushball
valve
1.fromthecrackofinterface
2.fromwrenchlocaon
1.Replaceushballvalve
2.Installwrenchagainorreplace
Leakingfromconnector 1.Pumpworkstoolong
2.Muchnoisefromthesha
1.WindmoreTeon
2.Insertthepipeineecve
length

contd...
PROBLEM PROBABLE CAUSE SOLUTION
Pumpisnormalbutno
purewater(Pleasemake
suretherestrictorisok
&thetemperatureof
thepumpisok)
1.Pre-ltersareblocked
2.ROmembraneisblocked
3.Pumphasnopressure
4.Flushsolenoidvalvedonotshuto
5.Connectorsorpipesareblocked
6.Flowrestrictorisblocked
1.ReplacethePPlter
2.Replacethemembrane
3.Repairthepump
4.Replacesolenoidvalve
5.Checkwholewaterroutestep
bystep
6.Replace&checkupits
locaon.
Leakageinpumphead
1.Sediment&pre-carbonareblocked.
2.Thewasherofthepumpheadis
ageingorblockedbythedirtinside
3.Flowrestrictorisblocked
4.Theboltsofthepumpheadisloose.
1.Replacethelters&repairthe
pump
2.Repairpumphead&oen
replacePPtoavoidblockin
pump.
3.ReplacetheFR
4.Tightenthebolts&checkup.
Pumpworks
intermientlyduring
autoushing.
1.Sediment&pre-carbonareblocked.
2.Thewasherofthepumpheadis
ageingorblockedbythedirtinside
3.Flowrestrictorisblocked
4.Theboltsofthepumpheadisloose.
1.Enhancesourcewater
pressureorreplacePPlter.
2.Checkuporrepairrelave
circuit.
Tankisfullbutwater
cannotowout(pls
checkiftankballvalve
isopenorblocked)
1.LowsourcewaterpressureorPP
blocked
2.Badcircuit
1.Enhancepressureto
0.045Mpa,checkairchamber
iftheseisleakageornot,&
replaceinme.
2.Replacepostlter
3.Replaceorrepairfaucettap.
Drainwaterkeep
owingwhileRO
systemstopworking
1.Withnoenoughpressureinthetank
2.Postlterblocked
3.Faucettapblocked
1.Replacevalve
Rosystemstarttoo
frequently,can’tstop
whentankisfullor
restartaeramoment.
1.Inletvalvecannotshutofully
2.Circumuence
1.RepairorreplaceHPS
2.Repacevalve
3.Adjusttankpressure&
HPS
Someoaterexistedin
purewater
1.HPSproblem
2.Checkvalve’sproblem
3.Toohighpressureintank
1.Re-ushthepostlter
2.Flushthetankorreplace
Muchnoisefromthe
pump
1.Thepostcarbonlterisn’t
cleanenough.
2.Floaterfromtank
1.Shortentheworkingme
2.Replacethesha
8
Table des matières
Manuels Système de filtration d'eau populaires d'autres marques

Wisy
Wisy LineAir 100 Manuel utilisateur

Schaffner
Schaffner Ecosine FN3446 Series Manuel d'utilisation

Pentair
Pentair FLECK 4600 SXT Guide de l'utilisateur

H2O International
H2O International H20-500 Manuel utilisateur

Renkforce
Renkforce 2306241 Manuel utilisateur

Neo-Pure
Neo-Pure TL3-A502 Manuel utilisateur