myone SMARTONE Manuel

myone S.r.l - Via T. Edison, 11 - 30035 Mirano (VE) - ITALY Tel. +39 041 412542 - Fax +39 041 412542
www.myoneautomation.com
Hinged doors’ automation installation and
maintenance manual SMARTONE
EN

- 2 -
Index
1. 1.Safety warnings
1.1 Machinery Directive
pag. 2
2. 2.Technical data
2.1 Use
2.2 Conditions of use
pag. 3
3. 3. References pag. 3
4. Installazione automazione
4. Automation installation
4.1 Positioning of drills to fasten SMARTONE automation with articulated arm (01FE0055)
4.2 Installation with articulated arm
4.3 Articulated arm for hinged door COD. 01FE0055
4.4 Positioning of drills to fasten SMARTONE automation with sliding arm (01FE0056)
4.5 Installation with sliding arm 01FE0056
4.6 Sliding arm for hinged door COD. 01FE0056
pag. 4
5. Application samples
5.1 Sliding arm hinged door COD. 01FE0056
5.2 Articulated arm hinged door COD. 01FE0055
5.3 Parallel of two automations, overlapping leaves
5.4 Parallel of two automations, rebated leaves
pag. 8
6. Limit switches adjustment and opening safety pag. 10
7. Connections pag. 11
8. Commands and power supply for accessories pag. 12
9. Operating
9.1 Auto-set and automatic closure time regulation
pag. 13
10. Accessories’ electrical connections samples
10.1 Wired rotating selector electrical connection
10.2 Soft touch / mobility-impaired soft touch electrical connection
pag. 14
11. Control terminal descriptioni pag. 15
12. SMARTONE hinged doors instruction manual
12.1 General safety advices
pag. 16
13. Maintenence book pag. 17
1. Safety warnings
In order to protect the safety of people, follow all the instructions carefully. An incorrect installation or use of the
product may lead to serious damage to people. Read carefully the instructions before starting to install the product.
The packaging materials (plastic, polystyrene, etc.) must not be left within reach of children as they are potential sources
of danger. Keep the instructions for future references. This product has been designed and built exclusively to be used as
indicated in this document. Any other use that is not explicitly indicated could compromise the product integrity and/or repre-
sent a source of danger. Before starting the installation, check the product integrity. Do not install the product in explosive
environments and atmospheres: the presence of ammable gases or fumes represents a serious danger for safety. Before
installing the motors, make all the structural changes related to safety clearances and to the protection or segregation of all
the areas in which there is risk of being crushed, cut or dragged, and danger areas in general.
Make sure the existing structure is up to standard in terms of strength and stability.
The motor manufacturer is not responsible for failure to use Good Working Methods when building the frames to be motorized
or for any deformation occurring during use. The safety devices (photocells, safety edges, emergency stops, etc.) must be in-
stalled taking into account: the regulations and directives in force, Good Working Methods, the installation area, the operation
logic of the system and the forces developed by the motorized door.
Apply the hazard area notices required by applicable regulations.
Each installation must clearly show the identication details of the motorized door.
CAUTION:
1.1 Machinery directive
Manufacturer: MYONE S.r.l
Address: Via T. Edison, 11 - 30035 - Mirano - Venice – ITALY
Declares that: The automation for hinged door mod. SMARTONE
has been built in order to be incorporated into machinery or to be assembled with other machinery to constitute machinery covered by Direc-
tive 2006/42/EC;
is in conformity with the essential safety requirements of the following additional EC directives:
• 2006/95/EC Low Voltage Directive.
• 2004/108/EC Electromagnetic Compatibility directive.
Furthermore, it declares that it is not allowed to put the machinery into service until the machinery into which it is to be incorporated or of
which it is to be a component has been identied and declared to be in conformity with the provisions of Directive 2006/42/EC and subse-
quent amendments.
Mirano, 23 July 2013 Daniele Vanin
(General Manager)

- 3 -
2. Techical data 2.1 Use
Using the automation with the maximum weight
could reduce the above mentioned performances.
The frequency of use is only indicative. It is col-
lected under average conditions of use and cannot
be dened for each single case.
Each automatic access may be affected by variable
elements such as: friction, balancing and envi-
ronmental factors, which may substantially alter both
the duration and the performance characteristics of
the automatic access or parts thereof. The installer
shall be responsible for adopting suitable safety
conditions for each particular installation.
SMARTONE SMARTONE-M
Power supply Wide range 115/230 Vdc 50/60 Hz Wide range 115/230 Vdc 50/60 Hz
Absorption 3 W stand by 3 W stand by
100 VA max power 100 VA max power
Frequency of use 100% 100%
Accessories power 24 Vdc = / 0,5 A max 24 Vdc = / 0,5 A max
Opening time 1,5÷8 s / 90° 1,5÷10 s / 90°
Closure time 1,5÷8 s / 90° 1,5÷10 s / 90°
Maximum torque 45 Nm 28 Nm (opening) 18 Nm (closing)
Operation type Motor opening – motor closure Motor opening – spring closure
Operating temperature -20°C / +55°C (batteries: -10°C / +50°C) -20°C / +55°C (batteries: -10°C / +50°C)
Protection degree IP31 IP31
Control panel 30DC1003 30DC1004
2.2. Conditions of use
Use not allowed
Limit dimensions
Recommended dimensions
kg
mm
0
0
50 100 200150 250
500
1000
1500
12
3
3
4
5
6
7
9
10
11
1
carter in alluminio ossidato
oxidized aluminium cover
profilo copertura porta led
covering led
5
3
4
2
testata laterale
side plug
motoriduttore 24 Vdc con
encoder
24 Vdc motor with encoder
leverismo molla
lever spring
molla
spring
batterie di emergenza
emergency battery
7
9
8
10
gruppo riduttore
reduction unit
centrale elettronica
electronic control unit
6
boccola attacco braccio
bushing arm connection
11
telaio automazione
frame automation
3. References
WARNING:
Operation and performances are guaranteed only with MYONE accessories and devices.
1- Oxidized aluminum cover
2- Covering LED
3- Side plug
4- Frame automation
5- 24 Vdc motor with encoder
6- Control panel
7- Reduction unit
8- Lever spring
9- Spring
10- Emergency battery
11- Bush for arm connection

- 4 -
1
2
4. Automation installation
4.1 Positioning of drills to fasten SMARTONE automation with articulated arm (01FE0055)
1- Check that the wall is straight and
smooth
2- Drill the holes respecting the
measures as in Pic.. A
3- Insert the dowels (stand. equipment)
or threaded M8 screws
4- Insert the screws but leave them loosen
(~6 mm) in order to hook up and shift
(rightward) the automation
5- Fasten rmly the automation to the wall
tightening the M8 screws
OPEN SX 20 mm
OPEN DX 30 mm
X*
cable entry cable entry
DOOR PIVOT SX
DOOR PIVOT DX
= HOLE M8
~ 6 mm
Fig. A
X* = 20mm (STANDARD) X* = STANDARD + 01FE0054 (75 mm)

- 5 -
4.2 Installation with articulated arm
Use the articulated arm 01FE0055 for outward opening doors looking from the automation side.
min. 600
290 100
55
~ 90°
30 (*85)
38
Pierce the leaf and fasten the articulated arm respecting the measures indicated in the pic.tures.
(*) If needed, use the extension bush 01FE0054 to increase the gap between the automation
and the arm to 85 mm.
M5 M5
To modify the length of the articulated arm:
1- Unscrew the 4 M5 screws
2- Extend/reduce the arm (+/-)
3- Tighten the 4 M5 screws
4.3 Articulated arm for hinged door COD. 01FE0055

- 6 -
1
2
4.4 Positioning of drills to fasten SMARTONE automation with sliding arm (01FE0056)
OPEN SX 20 mm
OPEN DX 30 mm
X*
cable entry cable entry
DOOR PIVOT SX
DOOR PIVOT DX
= HOLE M8
~ 6 mm
Fig. A
X* = 52mm (STANDARD) X* = STANDARD + 01FE0054 (110 mm)
1- Check that the wall is straight and
smooth
2- Drill the holes respecting the
measures as in Pic.. A
3- Insert the dowels (stand. equipment)
or threaded M8 screws
4- Insert the screws but leave them loosen
(~6 mm) in order to hook up and shift
(rightward) the automation
5- Fasten rmly the automation to the wall
tightening the M8 screws

- 7 -
4.5 Installation with sliding arm 01FE0056
Use the sliding arm 01FE0056 for inward opening doors looking from the automation side.
280
max 120
min 700
6
52 (*110)
OPEN
Fasten the sliding track on top of the leaf as shown in the pic.tures,
respecting the given measures and cutting the part of the track in
excess if the leaf is too narrow.
(*) If needed, use the extension bush 01FE0054 to increase the gap
between the automation and the track to 110 mm.
4.6 Sliding arm for hinged door COD. 01FE0056
Operate manually the leaf both in opening and closure to check the
absence of frictions.
Adjust the position mechanical stops of the leaf inside the track, as
shown in the pic.ture.

- 8 -
5. Application samples
31RM0001 Microwave radar. IP30
31RS0001 Safety sensor for hinged door.
DIN 18650 / EN16005 IP54
31ST0004 Surface
mounting wired
mobility-impaired
soft touch device.
IP54
5.1 Sliding arm hinged door COD. 01FE0056
5.2 Articulated arm hinged door COD. 01FE0055
31RM0001 Microwave radar. IP30
31RS0001 Safety sensor for hinged door.
DIN 18650 / EN16005 IP54
31SR0007 Surface mounting
wired rotating selector for
hinged door. IP54

- 9 -
5.3 Parallel of two automations, overlapping leaves
SMARTONE 2 SMARTONE 1
31RS0001 31RS0001
31RS000131RS0001
SMARTONE 1SMARTONE 2
5.4 Parallel of two automations, rebated leaves
How to synchronize 2 automations through LCD parameters set-up, overlapping leaves:
R parameter = 3
H parameter = from 1 to 9 (second leaf closure delay)
J parameter = 1 (1,5 sec. second leaf opening delay)
How to synchronize 2 automations through LCD parameters set-up, rebated leaves:
R parameter = 3
H parameter = 0 (no delay for second leaf)
J parameter = 0 (no delay for second leaf)
Connect the terminal INT.I 18 COM 10 OPEN 17 –SMARTONE 1- with INT.I 18 COM 10 OPEN 17 -SMARTONE 2-
INT.I 18
COM 10
OPEN 17
WARNING:
Connect the accessories (ex. radar, selectors, ecc.) in parallel between both the automations.
N.B. the set-up of the 2 parallel automations must be done pressing the PROG keys of both the control panels
simultaneously.
INT.I 18
COM 10
OPEN 17
Connect the terminal INT.I 18 COM 10 OPEN 17 –SMARTONE 1- with INT.I 18 COM 10 OPEN 17 -SMARTONE 2-
INT.I 18
COM 10
OPEN 17
INT.I 18
COM 10
OPEN 17

- 10 -
6. Limit switches adjustment and opening safety
“A” limit switch for maximum opening stop
“B” limit switch that excludes the safety sensor in opening
Cam that activates the limit switch for maximum opening stop
Cam that activates the limit switch that excludes the safety sensor in opening
NC terminal FCA11
NO terminal PHOTO RAL 12
NO terminal PHOTO RAL 12
A
B
Warning:
In order to adjust the cams, loosen the screws 1
and 2 (pic.A).
The cams adjustment must be done operating ma-
nually the leaf, before doing the set-up.
Once the adjustments are over, tighten the screws.
(g A)
12
Table des matières
Autres manuels myone Équipement d'éclairage
Manuels Équipement d'éclairage populaires d'autres marques

Qazqa
Qazqa Suplux SL 3 Black 103062 Manuel utilisateur

Commercial Electric
Commercial Electric 54568141 Manuel utilisateur

CREE LIGHTING
CREE LIGHTING 304 Series Manuel utilisateur

Goobay
Goobay 49867 Manuel utilisateur

ECOMAN ITALIA
ECOMAN ITALIA LED T8 Manuel utilisateur

Alkalite
Alkalite Krypton KT-81 Manuel utilisateur