Murdock BF38 Series Instructions d'installation et d'utilisation

BF38 & BF48 Series
Semi-Recessed Bottle Filler With Chiller
TECHNICAL ASSISTANCE TOLL FREE TELEPHONE NUMBER:
1.800.591.9360
Technical Assistance Fax: 1.626.855.4894
COMPLIES WITH
Member of
Murdock™ assumes no responsibility for use
of void or superseded data. © Copyright
Murdock Mfg., City of Industry, CA Member of
Morris Group International. Please visit
www.murdockmfg.com for most current
specifications.
7013-037-001 Date: 07/26/18
MURDOCK
15125 Proctor Ave.
City of Industry, CA
91746 U.S.A.
Phone 800-591-9360
626-336-4561
Fax 626-855-4894
www.murdockmfg.com
Federal
Public Law
111-380
(No Lead)
NOTES TO INSTALLER:
1. Please leave this documentation with the owner of the fixture when finished.
2. Please read this entire booklet before beginning the installation.
3. Check your installation for compliance with plumbing, electrical and other applicable codes.
Murdock warrants that every cooler, bottle filling station, packaged water chiller, fountain and accessory to be free
from defects in material and workmanship under normal use for one (1) year from date of install or eighteen (18)
months after the date of shipment from the factory, whichever comes first.
LIMITED WARRANTY - UNITED STATES & CANADA
LIMITED EXPORT WARRANTY - One year on parts only.
This warranty does not cover installation or labor charges and does not apply to materials, which have been
damaged by other causes such as mishandling or improper care or abnormal use. The repair or replacement of the
defective materials shall constitute the sole remedy of the Buyer and the sole remedy of Murdock under this
warranty. Murdock shall not be liable under any circumstances for incidental, consequential or direct charges
caused by defects in the materials, or any delay in the repair or replacement thereof. This warranty is in lieu of all
other warranties expressed or implied. Product maintenance instructions are issued with each unit and disregard
or non-compliance with these instructions will constitute an abnormal use condition and void the warranty.
Stainless steel must be protected on job site during construction and must be properly maintained after the water
has been introduced into the water cooler or drinking fountain, or Murdock’s limited warranty is void.
Murdock warrants the compressor and hermetically sealed refrigeration system, including cooling coil assembly
when part of the hermetically sealed refrigeration system, to be free from defects in material and workmanship
under normal use for an additional four (4) years from the end of the one (1) year period described above.
I N S TA L L AT I O N / M A I N T E N A N C E I N S T R U C T I O N S
Semi-Recessed Bottle Fillers

Prior to roughing consult with local, state, and federal codes for proper installation.
BF38 ROUGHING-IN AND DIMENSIONAL DRAWING
551
2"
(1410)
181
4"
(465)
351
2"
(902)
A.F.F.
B B
17"
(430)
BLOCKOUT 3"
(75) 21
8"
(55)
51
4"
(135)
11
8"
(30)
11
8"
(30)
155
8"
(395)
13
4"
(45)
101
8"
(260)
541
2"
(1385)
BLOCKOUT
93
4"
(250)
111
2"
(290)
BLOCKOUT
13
4"
(45)
21
4"
(57)
13
4"
(45)
111
2"
(290)
BLOCKOUT
101
2"
(265)
8"
(205)
8"
(205)
8"
(205)
8"
(205)
8"
(205)
8"
(205)
GENERAL DIMENSIONS:
1. ALL DIMENSIONS ARE IN INCHES (MM)
2. STOP VALVE NOT PROVIDED
NOTE: RIGHT, LEFT, AND REAR WASTE ORIENTATION
ARE OPTIONAL IF NEEDED FOR CALLOUTS INDICATED **.
A
** C
** C
A
IN
OUT
L
C
L
CD
EF
31
2"
(90)
1/4" PUNCHING, 22 PLACES FOR
ANCHORING HARDWARE BY OTHERS
3/8" OD COPPER SUPPLY INLET
1-1/4" O.D. WASTE OUTLET
ELECTRICAL SERVICE ROUGH
3/8" OD COPPER SUPPLY INLET (CHILLER)
3/8" OD COPPER SUPPLY OUTLET (CHILLER)
-MF10 MOUNTING FRAME ASSEMBLY
A
B
C
D
E
F
G
511
2"
(1310)
A.F.F.
G
Finished Floor
MURDOCK MFG. • 15125 Proctor Avenue • City of Industry, CA 91746 USA
Phone 800-453-7465 or 626-333-2543 • Fax 626-855-4860 • www.murdockmfg.com Member of
7013-037-001 Revised: 07/26/18
Page 2 of 12
I N S TA L L AT I O N / M A I N T E N A N C E I N S T R U C T I O N S
Semi-Recessed Bottle Fillers

BF48 ROUGHING-IN AND DIMENSIONAL DRAWING
Prior to roughing consult with local, state, and federal codes for proper installation.
551
2"
(1410)
181
4"
(465)
351
2"
(902)
A.F.F.
B B
17"
(430)
BLOCKOUT 3"
(75) 21
8"
(55)
51
4"
(135)
11
8"
(30)
11
8"
(30)
155
8"
(395)
13
4"
(45)
1"
(25)
101
8"
(260)
541
2"
(1385)
BLOCKOUT
93
4"
(250)
13
4"
(45)
21
4"
(57)
13
4"
(45)
111
2"
(290)
BLOCKOUT
101
2"
(265)
8"
(205)
8"
(205)
8"
(205)
8"
(205)
8"
(205)
8"
(205)
5"
(130)
GENERAL DIMENSIONS:
1. ALL DIMENSIONS ARE IN INCHES (MM)
2. STOP VALVE NOT PROVIDED
NOTE: RIGHT, LEFT, AND REAR WASTE ORIENTATION
ARE OPTIONAL IF NEEDED FOR CALLOUTS INDICATED **.
1/4" PUNCHING, 22 PLACES FOR
ANCHORING HARDWARE BY OTHERS
3/8" OD COPPER SUPPLY INLET
1-1/4" O.D. WASTE OUTLET
ELECTRICAL SERVICE ROUGH
3/8" OD COPPER SUPPLY INLET (CHILLER)
3/8" OD COPPER SUPPLY OUTLET (CHILLER)
D
A
** C
** C
D
A
ALT
IN
OUT
L
C
L
C
D
EF
48"
(1220)
A.F.F.
FINISHED FLOOR
-MF10 MOUNTING FRAME ASSEMBLY
A
B
C
D
E
F
G
G
MURDOCK MFG. • 15125 Proctor Avenue • City of Industry, CA 91746 USA
Phone 800-453-7465 or 626-333-2543 • Fax 626-855-4860 • www.murdockmfg.com Member of
7013-037-001 Revised: 07/26/18
Page 3 of 16
I N S TA L L AT I O N / M A I N T E N A N C E I N S T R U C T I O N S
Semi-Recessed Bottle Fillers

NOTE: BEFORE PERFORMING STEP 9 REFER TO ELECTRICAL INSTALLATION ON PAGE 6.
6. Completely flush water supply lines of all foreign debris, before connecting to the fixture.
INSTALLATION: (see drainage & mounting roughing-in pg. 2 or 3)
8. Install removable access panel using #10-32 x 1/2” provided.
9. Test for leaks and proper operation, and then install the door using the hinges provided.
2. Carefully remove all fixture components from packaging, preventing scratching or damage.
6. Attach hinged door assembly to mounting frame by latching insert clip hinges. Make necessary adjustments to
hinges with the adjustment screw to prevent door from rubbing on wall when opening. Refer to door hinge
adjustment detail below.
4. Make up the 3/8” O.D. Copper inlet supply connection to chiller and Bottle Filler.
3. Provide mounting surface, sufficient to support the fixture and loads on the fixture.
PRIOR TO INSTALLATION:
1. Read all installation instructions carefully, before proceeding.
4. Provide rough-ins as shown on the roughing-in and dimensional drawing, including water supply, drain pipe
and gravel drain well. (See pages 2 or 3 for rough-in details)
2. Using #10-32 x 1/2” Hex Btn Screws provided mount bottle filler mounting frame to the MF10 frame assembly.
3. Place the Chiller Unit onto the basepan of the MF10 Frame Assembly.
7. Make up all power connections to the ground, neutral & hot within the electrical box and chiller unit.
1. Insert MF10 Frame assembly into the rough-in block out and secure using 1/4”-20 UNC mounting hardware
(Provided by others)
5. On the semi-recessed bottler filler assembly, unlock and swing open the hinged door assembly to expose
internal components. Disconnect 1/4” O.D. polyethylene tube connection from the hinged door assembly. Then
remove the hinged door assembly from mounting frame by unlatching insert clip hinges.
5. Loosen slip nuts to orientate P-trap to desired direction then tighten slip nuts and make up 1-1/4” O.D. waste
connection.
ANGLE ADJUSTMENT HORIZONTAL ADJUSTMENT
HINGE ADJUSTMENT
Horizontal
Adjustment
Screw Phillips Head
Screwdriver
Door Hinge
Horizontal
Adjustment
Screw
Angle
Adjustment
Screw
Phillips Head
Screwdriver
Door Hinge
Angle
Adjustment
Screw
MURDOCK MFG. • 15125 Proctor Avenue • City of Industry, CA 91746 USA
Phone 800-453-7465 or 626-333-2543 • Fax 626-855-4860 • www.murdockmfg.com Member of
7013-037-001 Revised: 07/26/18
Page 4 of 16
I N S TA L L AT I O N / M A I N T E N A N C E I N S T R U C T I O N S
Semi-Recessed Bottle Fillers

START UP:
Air within the bottle filler system or the structure supply piping will cause an irregular spout outlet stream until
purged out by incoming water. Press and hold pushbutton until steady water stream is achieved.
SENSOR OPERATION INSTRUCTIONS:
Hold container to be filled just below the sensor in the center of the filler spout and then move the container
upward and water flow will start automatically. When the container is almost filled, lower the container below
the sensor until the water stops flowing. (see label on the bottle filler)
HAND OPERATION INSTRUCTIONS:
Hold container to be filled just below the filler tube in the center of the unit, then push pushbutton. When the
container is almost filled, release the pushbutton.
WATER TUBING CONNECTIONS:
NOTE: Insulation on all water tubes not shown (all PE water tubes are insulated).
MURDOCK MFG. • 15125 Proctor Avenue • City of Industry, CA 91746 USA
Phone 800-453-7465 or 626-333-2543 • Fax 626-855-4860 • www.murdockmfg.com Member of
7013-037-001 Revised: 07/26/18
Page 5 of 16
I N S TA L L AT I O N / M A I N T E N A N C E I N S T R U C T I O N S
Semi-Recessed Bottle Fillers
Keys
1/4" NCT x 1/4" OD
"Y" Strainer
(Chiller Inlet)
1/4" NCT x 1/4" OD
Push-In Union
(Chiller Outlet)
Electrical
Knockout
Thermostat
Adjustment
Removable
Access Door
18" PE Tubing
Air-Control Valve
Inlet Fitting
Air-Control Valve
Outlet Elbow
w/ Flow Control
Fill Spout

MURDOCK MFG. • 15125 Proctor Avenue • City of Industry, CA 91746 USA
Phone 800-453-7465 or 626-333-2543 • Fax 626-855-4860 • www.murdockmfg.com Member of
7013-037-001 Revised: 07/26/18
Page 6 of 16
OPTIONAL -WF1 WATER FILTER
See the following page for models with -WF1 Water Filter (BF38-WF1 or BF48-WF1)
I N S TA L L AT I O N / M A I N T E N A N C E I N S T R U C T I O N S
Semi-Recessed Bottle Fillers
FILTER MOUNTING
DETAIL
TO CHILLER "IN"
INSTALLED FILTER DETAIL
NOTES:
1. CUT AND DEBURR WATER LINE
TUBING AS REQUIRED.
2. ENSURE TUBING END IS NOT
DEFORMED BEFORE INSERTING IN
"Y" STRAINER.
3. CUT INSULATION AS REQUIRED TO
COVER WATER TUBING.
REMOVE TUBING FROM
"Y" STRAINER OUTLET &
INSTALL TO OUTLET OF
CHILLER
OUT
IN
MOUNT FILTER BRACKET
TO CORNER OF
MOUNTING FRAME
FROM SUPPLY
INLET
2
1
3
5
4
ITEM
PART NUMBER
DESCRIPTION
1
7012-311-000
WF1 FILTER 1500 GALLONS
2
1895-709-000
ELBOW, PUSH-IN, 1/4” O.D. x 1/4” STEM
3
2169-000-000
1/4: O.D. LLDPE TUBING, BLUE
4
7012-055-000
FOAM PIPE INSULLATION
5
7003-670-001
FILTER BRACKET ASSEMBLY

MURDOCK MFG. • 15125 Proctor Avenue • City of Industry, CA 91746 USA
Phone 800-453-7465 or 626-333-2543 • Fax 626-855-4860 • www.murdockmfg.com Member of
7013-037-001 Revised: 07/26/18
Page 7 of 16
OPTIONAL -WF1 WATER FILTER INSTALLATION
FILTER CARTRIDGE REPLACEMENT:
3. Remove and replace the cartridge turning clockwise to
secure.
1. Unlock and swing open bottle filler door, this allows access
to the filter and the inlet valve (provided by others). Turn
valve knob 1/4 turn clockwise to close.
4. Turn inlet 1/4 turn knob 1/4 turn counterclockwise to open
and test for leaks and proper operation before re-mounting
panel assembly to fixture.
2. With the filter assembly secured on the unit, hold the cap
firmly, turn the replaceable cartridge filter counterclockwise
to remove.
I N S TA L L AT I O N / M A I N T E N A N C E I N S T R U C T I O N S
Semi-Recessed Bottle Fillers
Note: It is recommended to place Shut-Off near Filter for
easy access.
1
WATER INLET
VALVE CLOSED
WATER INLET
VALVE OPEN
BOTTLE FILLER
ACCESS DOOR

1. -BAT Battery Operation: Peel off paper backing from hook & loop pads then press battery holder firmly
in place. (See Ref. Below). Connect the battery holder wires to the red sensor wires. Unit requires six
AA, alkaline or lithium batteries (not included). Note: When the battery holder is connected, the unit
active.
1A. Plug-In Operation: Plug transformer provided into GFCI protected electrical service, used by the semi-
recessed bottle filler. Plug in transformer to power supply and connect to red sensor wire.
ELECTRICAL INSTALLATION:
NOTE: PLUG IN POWER IS A STANDARD FEATURE.
2. Connect the blue sensor wires to the solenoid valve wires.(See Below)
FOR -BAT BATTERY OPERATION OPTION.
TRANSFORMER WIRING AND WATER TUBING CONNECTIONS:
MURDOCK MFG. • 15125 Proctor Avenue • City of Industry, CA 91746 USA
Phone 800-453-7465 or 626-333-2543 • Fax 626-855-4860 • www.murdockmfg.com Member of
7013-037-001 Revised: 07/26/18
Page 8 of 16
I N S TA L L AT I O N / M A I N T E N A N C E I N S T R U C T I O N S
Semi-Recessed Bottle Fillers
Plug-In
Transformer
18" PE Tubing
Sensor
Solenoid Valve
Inlet Fitting
Solenoid Valve
Outlet Elbow
w/ Flow Control
Optional -BAT 9V Battery Pack
Fill Spout
Electrical
Knockout
Thermostat
Adjustment
Removable
Access Door
Keys
MF10 MOUNTING
FRAME ASSEMBLY
1/4" NCT x 1/4" OD
"Y" Strainer
(Chiller Inlet)
1/4" NCT x 1/4" OD
Push-In Union
(Chiller Outlet)
Air-Control Valve
Inlet Fitting

MURDOCK MFG. • 15125 Proctor Avenue • City of Industry, CA 91746 USA
Phone 800-453-7465 or 626-333-2543 • Fax 626-855-4860 • www.murdockmfg.com Member of
7013-037-001 Revised: 07/26/18
Page 9 of 16
NOTE: Bottle Counter Has Multiple Functions
Reset/ Mode Button
• Counts refilled bottles, otherwise purchased
• Adjustable for Units with and without filters
• “REPLACEMENT FILTER” alert function
• Alert reset, when filter is replaced
BOTTLE COUNTER ADJUSTING & RESETTING INSTRUCTIONS:
Bottle Counting Function
The software applies a flow volume of approximately 16.9 fl oz (volume in standard size plastic water
bottle) to each bottle counted. If the flow volume is less than 16.9 fl oz there will be no count but the
volume will accumulate, so that part way through the next cycle the total bottle count will change.
Description
Illuminated LCD display, counts bottles, and has a filter replacement alert function
ILLUMINATED LCD DISPLAY
I N S TA L L AT I O N / M A I N T E N A N C E I N S T R U C T I O N S
Semi-Recessed Bottle Fillers

MURDOCK MFG. • 15125 Proctor Avenue • City of Industry, CA 91746 USA
Phone 800-453-7465 or 626-333-2543 • Fax 626-855-4860 • www.murdockmfg.com Member of
7013-037-001 Revised: 07/26/18
Page 10 of 16
RESET/MODE BUTTON
Counter Modes
Located on the back of the display you will find the reset button for the mode settings. The Reset/Mode
selection button is accessible by removing the top of the bottle filler, then locate the large hole in the
back of the display mounting bracket. Use your finger or nonconductive implement to depress the
Reset/Mode Selection Button.
!!!DO NOT USE SHARP OR METAL IMPLEMENTS!!!
With this reset button, you are able to indicate whether or not the unit has a filter or does not have a
filter. The reset button will also take away the “REPLACE FILTER” alert once the filter has been
replaced.
CLEARING “REPLACE FILTER” ALERT:
NOTE: This Function only applies if the system as a filter
• Replace old filter with new filter.
• Depress the Reset/Mode selection button for 2 SECONDS
• The “REPLACE FILTER” will no longer appear on the display
• Test by actuating the bottle filler, alert will not appear.
Systems With or Without Filter
• Depress the Reset/Mode selection button for 6
Seconds, the number of seconds will count up on the
display.
• At the end of the 6 seconds, “FLTR YES” or “FLTR NO”
WILL APPEAR on the display.
• “FLTR YES” means that there is a filter in the system
and a “REPLACE FILTER” alert WILL APPEAR on the
display when the maximum filter flow volume is reached.
• “FLTR NO” means that there is no filter in the system
and a “REPLACE FILTER” alert WILL NOT APPEAR
on the display.
• Release button when the option required is on the
display (Filter Yes or No)
NOTE: When the volume accumulates to 1500 gallons (recommended maximum filter flow volume)
the “REPLACE FILTER” alert will appear on the display every time the bottle filler is activated.
FILTER REPLACEMENT FUNCTIONS:
I N S TA L L AT I O N / M A I N T E N A N C E I N S T R U C T I O N S
Semi-Recessed Bottle Fillers
Ce manuel convient aux modèles suivants
3
Table des matières
Autres manuels Murdock Distributeur