Movincool CM 25 Manuel utilisateur

OPERATION MANUAL
CM25
SERIAL NUMBER FROM OCTOBER 2009 (1009) TO PRESENT
READ THIS MANUAL CAREFULLY FOR INSTRUCTIONS ON CORRECT
INSTALLATION AND USAGE, AND READ ALL SAFEGUARDS.
SECCIÓN EN ESPAÑOL
SECTION EN FRANÇAIS
AVAILABLE AT WWW.MOVINCOOL.COM

© 2009 DENSO SALES CALIFORNIA, INC.
All rights reserved. This book may not be reproduced or copied, in
whole or in part, without the written permission of the publisher.
DENSO SALES CALIFORNIA, INC. reserves the right to make
changes without prior notice. MovinCool is a registered trademark of
DENSO Corporation.

OPERATION MANUAL
CM25

Table of Contents
FOREWORD ...................................................................................................... 6
Definition of Terms................................................................................ 6
GENERAL WARNINGS & CAUTIONS.............................................................. 6
UNPACKING ...................................................................................................... 7
INVENTORY....................................................................................................... 8
INSTALLATION ................................................................................................. 9
Unit Overview ........................................................................................ 9
Clearance Requirement ...................................................................... 10
Mounting CM25 to Roof Structure ..................................................... 11
Drain Hose Connection....................................................................... 16
Packing Attachment............................................................................ 17
Ducting With Typical Drop Ceiling..................................................... 18
Condenser Duct Installation (Optional)............................................. 19
Power Supply and Field Wiring Connection..................................... 20
DIP Switch Configuration and Setting............................................... 22
Supplied Wall Mounted Controller Connection................................ 24
Field-Supplied Millivolt Wall Thermostat Connection...................... 29
Warning Signal Connection (Output Signal)..................................... 32
Fire Alarm Connection (Input Signal)................................................ 34
FEATURES OF WALL MOUNTED CONTROLLER........................................ 36
FEATURES OF CM25...................................................................................... 37
OPERATION (Wall Mounted Controller ONLY) ............................................ 38
Controller Panel................................................................................... 38
Standby Mode...................................................................................... 41
Set Clock .............................................................................................. 41
Operate in COOL Mode....................................................................... 42
Operate in FAN ONLY Mode............................................................... 43
Change Mode....................................................................................... 43
Change Temperature Scale ................................................................ 43
Keypad Lock ........................................................................................ 43
Program Feature.................................................................................. 43
Program Setting .................................................................................. 44
Select Program Sequence Number.................................................... 45
Set Start Time and Operation Mode................................................... 45
Set Stop Time ...................................................................................... 46
Exit Program Mode.............................................................................. 46
View Program ...................................................................................... 46
Edit Program........................................................................................ 47
Delete Program.................................................................................... 47
Run and Stop Program ....................................................................... 47

Program Plan Sheet ............................................................................ 48
SELF-DIAGNOSTIC CODES & BUZZER PATTERN...................................... 49
Self-Diagnostic Codes ........................................................................ 49
Table of Self-Diagnostic Codes.......................................................... 49
Buzzer Pattern ..................................................................................... 50
DAILY INSPECTION & MAINTENANCE......................................................... 51
Cleaning Air Filters ............................................................................. 51
Cleaning Condenser Air Intake .......................................................... 51
Ground Fault Breaker Testing............................................................ 51
TROUBLESHOOTING ..................................................................................... 52
TECHNICAL SPECIFICATIONS...................................................................... 58

6
FOREWORD
Congratulations on purchasing the MovinCool air conditioner. This manual
explains how to assemble, install and operate the MovinCool CM25 air
conditioning unit. Please read this operation manual thoroughly to familiarize
yourself with the features of the unit and to ensure years of reliable operation.
You may also find it useful to keep this operation manual on hand for reference.
Components and/or procedures are subject to change without prior notice.
Definition of Terms
WARNING: Describes precautions that should be observed in order
to prevent injury to the user during installation or unit operation.
CAUTION: Describes precautions that should be observed in order
to prevent damage to the unit or its components, which may occur
during installation or unit operation if sufficient care is not taken.
Note: Provides additional information that facilitates installation or unit operation.
GENERAL WARNINGS & CAUTIONS
1. All electrical work should only be performed by qualified electrical personnel.
Repair to electrical components by non-certified technicians may result in
personal injury and/or damage to the unit. All electrical components replaced
must be genuine MovinCool parts, purchased from an authorized reseller.
2. Installation should be conducted by qualified technician only. DENSO and
DENSO affiliate are not responsible for injuries and/or damages caused by
improper installation.
3. Do not place water or any other liquid on the unit. This can cause damage to
the unit and increase the risk of electrical shock.
4. Do not sit or stand on the unit.
5. Do not place hands or any object in the cool air outlet or exhaust duct.
Touching the fan, which is rotating at a high speed, is very hazardous.

7
UNPACKING
Remove the package as shown below.
Note: The unit can be installed while the unit is on the pallet.
(See “Mounting CM25 to Roof Structure” on page 11 to 13.)
PACKAGE
MOUNTING HOLES
UNIT
PALLET

8
INVENTORY
After unpacking your MovinCool unit, please check to make sure you have the
following items:
1. CM25 MovinCool Unit (1)
2. Operation Manual/Product
Registration (1)
3. Clip (1)
4. Packing (1)
5. Vibration Isolator (4)
6. Wall Mounted Controller (1)
7. Shield Wire (1)
8. Screw (4)
Note: If any of these items were not included in the box or appear damaged,
please contact your MovinCool reseller for replacement.
CM25 UNIT WALL MOUNTED CONTROLLER
SCREW FOR WALL
MOUNTED CONTROLLER
OPERATION MANUAL /
PRODUCT REGISTRATION
CLIP
VIBRATION ISOLATOR
PACKING (1.8 x 43.9 x 0.2 in)
SHIELD WIRE FOR WALL
MOUNTED CONTROLLER (12 ft)

9
INSTALLATION
Unit Overview
WARNING: Remove protective cardboard from condenser air intake
after installation.
COOL AIR EXHAUST
(12 in DIA. FLANGE)
DRAIN PIPE FOR PUMP
CONDENSER (HOT) AIR EXHAUST
EVAPORATOR (ROOM)
AIR INTAKE
(12 in DIA. FLANGE)
MOUNTING HOLES
CONDENSATE PAN DRAIN
FOR MAINTENANCE
SERVICE PANEL
WALL MOUNTED CONTROLLER/
MILLIVOLT WALL THERMOSTAT
WIRE INLET
CONDENSER AIR INTAKE POWER CORD INLET
SIGNAL WIRE INLET
STOP SWITCH

10
INSTALLATION (cont.)
Clearance Requirement
51.3
53.0
All dimensions are in inches.
Unit Weight: 310 lb (140 kg)
29.8
DIA. 0.6
4.0
15.7
DIA. 11.8
DIA. 11.8
14.4
4.0
31.5
0.6
11.4
20.1
14.4
6.5
4.0
WALL
INTAKE
Minimum
clearance
20.0 in
from wall
Minimum
clearance
40.0 in
from wall
EXHAUST
CEILING
Top of the unit should not contact
any building structure or object.
WALL
Autres manuels pour CM 25
2
Table des matières