Monarch nice3000 Manuel utilisateur


Contents
Chapter 1 Overview............................................................................................... 4
Chapter 2 Product Information .............................................................................. 6
2.1 Designation Rules ............................................................................................................6
2.2 Mounting Dimensions.......................................................................................................6
2.3 Electrical Specifications....................................................................................................8
2.4 Braking Resistor .............................................................................................................11
2.5 Terminal Descriptions .....................................................................................................12
Chapter 3 Component Description ...................................................................... 16
3.1 Onboard Keypad Description .........................................................................................16
3.2 Use of the LED Operation Panel ....................................................................................18
3.3 CTB Board......................................................................................................................20
3.4 Display Board (MCTC-HCB)...........................................................................................22
3.5 CCB Board .....................................................................................................................29
Chapter 4 Use of the NICE3000.......................................................................... 32
4.1 Wiring Diagrams Under Default Parameter Settings......................................................32
4.2 Description of Shaft Signals ...........................................................................................33
4.3 Typical Commissioning...................................................................................................35
Chapter 5 Function Code Table........................................................................... 52
Chapter 6 System Application ............................................................................. 72
6.1 Parallel Mode and Group Mode......................................................................................72
6.2 Emergency Evacuation at Power Failure .......................................................................75
6.3 Opposite Door Control....................................................................................................78
Chapter 7 Troubleshooting .................................................................................. 82
7.1 Description of Fault Levels .............................................................................................82
7.2 Fault Information and Troubleshooting...........................................................................83


1
Overview

Overview Brief NICE3000 Instruction Manual
- 4 -
Chapter 1 Overview
To facilitate the users who use the NICE3000 control system for the first time to understand
how to commission the control system as quickly as possible, this manual briefly describes
the specifications, wiring, common parameter setting, and common commissioning of the
NICE3000.
The application range of the NICE3000 is as follows:
Maximum Number
of Floors
Maximum Elevator
Speed Parallel/Group Mode Inputs Outputs
40 4 m/s 2 to 8 elevators 24 6
The NICE3000 series elevator integrated control system mainly includes the elevator
integrated controller, car top board (MCTC-CTB), hall call board (MCTC-HCB), car call
board (MCTC-CCB), and optional door pre-open module, and remote monitoring system.
The following figure shows the system architecture.
Figure 1-1 System architecture of the NICE3000
LED operation
panel
Host
computer
CANbus
MCTC-HCB
MCTC-HCB Load cell
MCTC-HCB
Modbus
MCTC-CCB
MCTC-CTB
PMSM or
asynchronous motor

2
Product Information

Product Information Brief NICE3000 Instruction Manual
- 6 -
Chapter 2 Product Information
2.1 Designation Rules
Figure 2-1 Designation rules of the NICE3000
NICE series
integrated controller For lift Controller
model Three-phase
400 V Motor power
NICE-L-A-40 11
Controller
Model A B
Adaptable
Motor
Asynchronous
Motor PMSM
Encoder
Incremental
encoder (push-
pull output, open-
collector output)
Incremental
encoder with
commutation
signals UVW
Incremental
SIN/COS
encoder with
sinusoidal
commutation
signals
Absolute SIN/
COS encoder
with EnDat serial
communications
protocol
(Heidenhain
ECN1313/413)
PG card
Main control
board (MCB)
integrating
the PG card,
requiring no
external one
MCTC-PG-B
MCTC-PG-D
MCTC-PG-C
MCTC-PG-E MD32PG5
2.2 Mounting Dimensions
The NICE3000 controller has three sizes: SIZE-C, SIZE-D, and SIZE-E, as shown in the
following figure. SIZE-F is a customized model with different appearances but the same
installation mode.
The following figure and table show the appearance and physical dimensions of the
NICE3000 controller.

Brief NICE3000 Instruction Manual Product Information
- 7 -
Figure 2-2 Appearance and mounting dimensions of the NICE3000 controller
Table 2-1 Sizes of the NICE3000 controller
Size Model A
(mm)
B
(mm)
H
(mm)
W
(mm)
D
(mm)
Hole
Diameter
(mm)
Gross
Weight
(kg)
Structure
SIZE-C P ≤5.5
kW 140 344 355 220 150 6.5 10 L
SIZE-D
5.5 kW
< P ≤
15 kW
150 334.5 347.5 223 167.5 6.5 12 L
5.5 kW
< P ≤
15 kW
190 305 322 208 212 6 6.5 L1
SIZE-E
15 kW
< P ≤
30 kW
235 541.5 554.5 289.6 223 6.5 14.5 L
SIZE-F
30 kW
< P ≤
45 kW
250 598 620 380 262 10 34 L
Note
1. The NICE3000 controller of other power ratings, such as above 45 kW is rarely applied in the
elevator, and therefore, specifications are not provided here. For future detail on the options and
availability, please contact Monarch.
2. SIZE-D has two types, sheet-metal (structure L) and plastic (structure L1), varying slightly in the
size.

Product Information Brief NICE3000 Instruction Manual
- 8 -
2.3 Electrical Specifications
Table 2-2 NICE3000 models and electrical specifications
System Model Power
Capacity (kVA)
Input Current
(A)
Output
Current (A)
Motor Power
(kW)
AC supply voltage: single-phase 220 V, range: –15% to 20%
NICE-L-A/B-2002 2.3 13.2 5.2 1.1
NICE-L-A/B-2003 3.4 17 7.5 1.5
220-NICE-L/L1-A/B-4007 9.8 29 10.3 2.2
220-NICE-L/L1-A/B-4011 12.1 36 15.5 3.7
220-NICE-L/L1-A/B-4015 13.9 41 19 4.0
220-NICE-L-A/B-4018 17.3 40 22.5 5.5
220-NICE-L-A/B-4022 23.1 49 27.7 11
220-NICE-L-A/B-4030 33 61 34.6 15
AC supply voltage: three-phase 220 V, range: –15% to 20%
NICE-L-A/B-2002 4.0 11.0 9.6 2.2
NICE-L-A/B-2003 5.9 17.0 14.0 3.7
220-NICE-L/L1-A/B-4007 17.0 29.0 18.0 4.0
220-NICE-L/L1-A/B-4011 21.0 36.0 27.0 5.5
220-NICE-L/L1-A/B-4015 24.0 41.0 33.0 7.5
220-NICE-L-A/B-4018 30.0 40.0 39.0 11.0
220-NICE-L-A/B-4022 40.0 49.0 48.0 15.0
220-NICE-L-A/B-4030 57.0 61.0 60.0 18.5
AC supply voltage: three-phase 380 V, range: –15% to 20%
NICE-L-A/B-4002 4.0 6.5 5.1 2.2
NICE-L-A/B-4003 5.9 10.5 9.0 3.7
NICE-L-A/B-4005 8.9 14.8 13.0 5.5
NICE-L/L1-A/B-4007 11.0 20.5 18.0 7.5
NICE-L/L1-A/B-4011 17.0 29.0 27.0 11.0
NICE-L/L1-A/B-4015 21.0 36.0 33.0 15.0
NICE-L-A/B-4018 24.0 41.0 39.0 18.5
NICE-L-A/B-4022 30.0 49.5 48.0 22.0
NICE-L-A/B-4030 40.0 62.0 60.0 30.0
NICE-L-A/B-4037 57.0 77.0 75.0 37.0
NICE-L-A/B-4045 69.0 93.0 91.0 45.0

Brief NICE3000 Instruction Manual Product Information
- 9 -
Note
1. In terms of single-phase and three-phase 220 VAC, NICE-L-A/B-2002 and NICE-L-A/B-2003
are specially designed for 220 VAC. The other models that are marked by prefixing "220-" are
modified from the three-phase 380 VAC models.
2. Same models are available for single-phase 220 VAC and three-phase 220 VAC. Pay attention
to the power rating of the adaptable motor during the use.
3. Select the proper controller output current based on the motor rated current. Ensure that the
controller output current is equal to or greater than the motor rated current.
Table 2-3 Technical specifications of the NICE3000
Item Specification
Basic
specifications
Maximum frequency 99 Hz
Carrier frequency 0.5–16 kHz, adjusted automatically based on the
load features
Motor control mode sensorless flux vector control (SFVC), closed-loop
vector control (CLVC)
Startup torque 0.5 Hz: 180% (SFVC)
0 Hz: 200% (CLVC)
Speed stability
accuracy ±0.5% (SFVC) ±0.05% (CLVC)
Torque control
accuracy ±5% (CLVC)
Overload 60s for 150% of the rated current, 1s for 200% of the
rated current
Motor auto-tuning With-load auto-tuning; no-load auto-tuning
Distance control Direct flooring mode in which the leveling position
can be adjusted flexibly
Acceleration/
Deceleration curve N curves generated automatically
Re-leveling Leveling re-adjustment after the car load changes
Slow-down New reliable slow-down function, automatically
identifying the position of the slow-down shelf
Shaft auto-tuning 32-bit data, recording the position in the shaft
accurately
Leveling adjustment Flexible and easy leveling adjustment function
Startup torque
compensation Humanized load cell auto-tuning
Real-time clock Real-time clock for time-based floor service, peak
service and automatic password