MONARCH INSTRUMENT RLS Manuel utilisateur

Instruction Manual
RLS and RLS24
Rugged Laser Sensors
15 Columbia Drive
Amherst, NH 03031 USA
Phone: (603) 883-3390 • Fax: (603) 886-3300
E-mail: [email protected]
Website: www.monarchinstrument.com

In order to comply with EU Direcve 2012/19/EU on Waste Electrical
and Electronic Equipment (WEEE): This product may contain material
which could be hazardous to human health and the environment. DO NOT
DISPOSE of this product as unsorted municipal waste. This product needs to be
RECYCLED in accordance with local regulaons; contact your local authories for
more informaon. This product may be returnable to your distributor for recycling;
contact the distributor for details.
SAFEGUARDS AND PRECAUTIONS
Laser Hazards:
Eye injury from beam - Do not look into the direct or reected beam; can cause eye
injury up to 25 [7.5 m] away.
Visual interference (glare) with pilots and drivers - Interferes with vision up to 525
(160 m) away. Can be a distracon up to 1 mile [1.6 km] away. NEVER point any
laser towards aircra or vehicles; it is unsafe and illegal.
Read and follow all instrucons in this manual carefully, and retain this
manual for future reference.
Do not use this instrument in any manner inconsistent with these operang
instrucons or under any condions that exceed the environmental specicaons
stated.
This instrument is not user serviceable. For technical assistance, contact the sales
organizaon from which you purchased the product.
Diode Laser
Max. Output Power: <1 milliwa
Wavelength: 650 nanometers (visible light)
Beam Divergence: <18 milliradian
Output: Connuous (CW)
Laser Hazard Classicaon: Class 2
Safe Use Guidance:
Class 2 lasers are considered safe
for accidental eye exposure. Do
not look or stare into beam. Do
not aim at aircra. This is not a
toy. Always supervise children.
Manufacturer:
Monarch Instrument
15 Columbia Drive
Amherst, NH 03031 USA
Country of Origin: USA
Contact info: www.monarchinstrument.com

Monarch Instrument’s Limited Warranty applies.
See www.monarchinstrument.com for details.
Warranty Registraon and Extended Warranty Coverage informaon is available
online at www.monarchinstrument.com.
Monarch Instrument holds the following US trademarks and registraons, all rights
reserved: illumiNova®, Nova-Pro®, Nova-Strobe™, DataChart™, Track-It™.
TABLE OF CONTENTS
1.0 OVERVIEW ...................................................................... 1
2.0 CONNECTION DETAILS .................................................... 2
3.0 OPERATING INSTRUCTIONS ........................................... 2
4.0 SPECIFICATIONS ............................................................. 5
4.1 Dimensions ............................................................... 6
4.2 Environmental ........................................................... 6
4.3 Compliance ................................................................ 6
5.0 ACCESSORIES .................................................................. 7

1
1.0 OVERVIEW
The RLS and RLS24 Rugged Laser Sensors are opcal reecve sensors
with a visible red laser light source and green LED on-target indicator. The
sensors are rated IP67 and are designed to survive accidental exposure to
water, dirt, oil, and other contaminants.
The Class 2 laser source acts as the aiming device during setup and can
accurately measure speeds from 1-250,000 RPM from a distance of up
to 25 feet with a maximum oset angle of 60 degrees from the rotang
object. The sensors are housed in an M20x1.5 threaded 316L stainless steel
tube and have a waterght M12 4 pin socket on the backend. A 90-degree
mounng bracket and 2 jam nuts are provided for mounng.
The RLS and RLS24 are supplied with a removable 3 m [9.8 .] cable with
a waterght M12 4 Pole Female connector on one end and a 3.5 mm [1/8
inch] male stereo plug (RLS-P or RLS24-P) or 4 nned wires (RLS-W or
RLS24-W) on the other end. An oponal 25 . [7.6 m] extension cable EC-
25P is available with a female socket for the plug on one end and a 3.5 mm
[1/8 inch] male stereo plug on the other (for RLS-P or RLS24-P).
The sensor can be powered by 4-15 V dc or 10-24 V dc and is available in
the following conguraons:
Model Power Requirement Removable 3 m Cable
RLS-P 4 – 15 V dc ±20% 0.5W M12 4 Pole Female connector to
1/8 in. [3.5 mm] male stereo plug
RLS-W 4 – 15 V dc ±20% 0.5W M12 4 Pole Female connector to
nned wires
RLS24-P 10 – 24 V dc ±20% 0.5W M12 4 Pole Female connector to
1/8 in. [3.5 mm] male stereo plug
RLS24-W 10 – 24 V dc ±20% 0.5W M12 4 Pole Female connector to
nned wires

2
2.0 CONNECTION DETAILS
Connecon to the sensor is via the waterght M12 connector on the end
of the sensor. The sensor may be ordered with one of two cables: the -P
with a 3.5 mm stereo connector or the -W with nned wires as shown
below.
RLS-W with wires RLS-P with plug

3
3.0 OPERATING INSTRUCTIONS
Plug the sensor into an appropriate power source (RLS = 4-15 V dc,
RLS24 = 10-24 V dc). The RLS-P will work directly with all Monarch
handheld tachometers and stroboscopes that accept pulse input through
an input jack (e.g., PLT200, PLS, dax, dbx, DBL, pbx, PBL, Nova-Pro® 300,
Nova-Pro® 500). The RLS-W and RLS24-W will work with all Monarch panel
instruments that accept pulse inputs (e.g., ACT series, Frequency to Analog
Converters, DataChart™ 1250, DataChart™ 6000) and vibraon data
collectors. A sensor power supply (SPSR-IM) with BNC output is available
for those applicaons that require a separate power source for the sensor
(RLS-P only).
The RLS Rugged Laser Sensor can detect a reected pulse from a target
consisng of T-5 Reecve Tape or high-contrast color dierences (such
as black and white) at distances up to 25 feet [7.6 m] from the rotang
object and angles up to 60 degrees. For most applicaons, a ½" [12 mm]
square piece of T-5 Reecve Tape should be applied to a clean area on
the rotang object as a target. At slow speeds (<500 RPM) best results will
be obtained by aiming the laser perpendicular (90°) to the target using a
narrow piece of reecve tape – typically 0.2 inch [5 mm] wide.

4
The RLS should be opcally aligned to illuminate the On-Target Indicator
once per revoluon. It is recommended that the opcal sensor be placed
at a slight angle (15 degrees) from perpendicular so that the sensor will
receive only pulses from the reecve marker. Triggering from contrasng
colors should be done perpendicular to the target. The RLS should be at
least 1 inch from the reecve target to avoid false triggering. The green
LED On-Target Indicator will blink at the input frequency rate when the RLS
is properly aimed.
Note: The green LED On-Target Indicator will blink (on/o) at slow speeds
and remain on steady at high speeds.
Note: Opcal speed sensors require environments that are clean and free
of mist, steam, dirt, oil, and other contaminants to funcon properly. The
RLS can survive these condions, but it will not funcon properly if the
opcs are contaminated. Carefully cleaning or drying the opcs will restore
normal operaon.

5
4.0 SPECIFICATIONS
Specicaons* RLS Rugged Laser
Speed Range 1 - 250,000 RPM
Illuminaon Visible red laser
Laser Specicaons:
Classicaon
Class 2 (per IEC 60825-1:2014)
This product complies with IEC60825-1 Ed. 3 and 21 CFR
1040.10 and 1040.11 except for deviaons pursuant to
Laser Noce No. 50 of June 2007.
Laser Output 1 mW max
Laser Operaon Connuous
Laser Wavelength 650nm (visible red)
Beam Divergence <18 mrad
Beam Diameter 4 x 7 mm typical at 2 m
Laser Diode Life 8,000 operang hours MTBF (1-year warranty)
On-Target Indicator Green LED on tube body - acve when pulse present
Operang Range Up to 7.6 m [25 .] and 60° oset from target
Power
Requirements
RLS-W and RLS-P: 4 - 15 V dc ±20% 0.5W
RLS24-W and RLS24-P: 10 - 24 V dc ±20% 0.5W
Output
Standard: Open Collector with internal pull up resistor
(5600 ohm) to supply voltage; posive pulse when
target present
Note: On 24 V unit output voltage = input voltage – 5 V.
Oponal: Negave pulse, true open collector,
3.3 V output (TTL); contact factory
Material Tube: 316L stainless steel Nosepiece: ABS
*Specicaons are subject to change without noce.

6
4.1 Dimensions
4.2 Environmental
This product is rated IP67 when used with supplied cables.
Operang Temperature: -10 °C to +50 °C (14 °F to 122 °F)
Storage Temperature: -40 °C to +80 °C (-40 °F to 170 °F)
4.3 Compliance
• CE Compliant
• Low Voltage Direcve (LVD) 2014/35/EU
• Electromagnec Compability Direcve (EMC) 2014/30/EU
• Restricon of Hazardous Substances (RoHS 3) Direcve 2015/863/EU

7
5.0 ACCESSORIES
See Accessories webpage for details.
SPSR-IM: Self-Powered Sensor
Interface module
PN: 6150-021
EC-25P: Extension Cable
PN: 6180-028
RLS-P Cable: 3 m cable
with M12 connector to 3.5 mm [1/8 in.]
male stereo plug
PN: 6180-085
RLS-w Cable: 3 m cable
with M12 connector to nned leads
PN: 6180-084
RLS-Nut: Jam Nut M20 x 1.5 x 10 mm
Two required to secure to Mounng Bracket
PN: 1053-0189-001
RLS-Mount: Mounng Bracket
90° sloed
PN: 1052-4350-112
Reecve Tape
T-5 (single pack), 5 feet - PN: 6180-070
T-5 (2-pack), 5 feet each - PN: 6180-069
T-50, 50 feet - PN: 6180-072
T-5WP (waterproof), 5 feet - PN: 6180-079
Ce manuel convient aux modèles suivants
1
Table des matières
Autres manuels MONARCH INSTRUMENT Accessoires

MONARCH INSTRUMENT
MONARCH INSTRUMENT SLS-115 Manuel utilisateur

MONARCH INSTRUMENT
MONARCH INSTRUMENT SPSR-115/230 Series Manuel utilisateur

MONARCH INSTRUMENT
MONARCH INSTRUMENT SPSR-115/230 Series Manuel utilisateur

MONARCH INSTRUMENT
MONARCH INSTRUMENT ROLS Manuel utilisateur

MONARCH INSTRUMENT
MONARCH INSTRUMENT ROLS Manuel utilisateur

MONARCH INSTRUMENT
MONARCH INSTRUMENT IRS Manuel utilisateur

MONARCH INSTRUMENT
MONARCH INSTRUMENT SLS-115 Manuel utilisateur

MONARCH INSTRUMENT
MONARCH INSTRUMENT ROS-HT-W-25 Manuel utilisateur