I. INTRODUCTION...............................................................2
Safety Cautions
II. INSTALLATION................................................................5
Cautions............................................................................5
Installation Placement.......................................................6
Installation, Step-by-step...................................................7
Storage..............................................................................12
III. OBTAINING SERVICE .....................................................13
IV. GENERAL PRODUCT SPECIFICATIONS.......................14
Battery Packs
V. WARRANTY INFORMATION...........................................15

3
Thank you for purchasing the Minuteman XRT series of external Battery
Packs for your MINUTEMAN Uninterruptible Power Supply system. It
has been designed and manufactured to provide many years of trouble-
free service.
The batteries used in the XRT series are sealed, maintenance-free, lead-
acid batteries, with the electrolyte completely absorbed in the plates and
separator material. For maximum battery life, the battery packs should
be kept as cool as practical indoors. Expected average battery life is 5
years. Replacement batteries and additional battery packs are available
from Minuteman or your local distributor or dealer. Please see the
SERVICE POLICY section of this manual about the options available for
replacement batteries.
When batteries are replaced, dispose of the batteries according to local
regulations or return the batteries to your dealer or distributor for proper
disposal. If you cannot dispose of the old batteries, they may be returned
to Minuteman for proper disposal. Call Minuteman Technical Support for
instructions on returning the batteries.
IMPORTANT!
Please read this manual before installing your Battery Pack, as it
provides the information to correctly set up your system for maximum
safety and performance. If factory service or customer support is
required, information on how to contact Minuteman is included. If you
experience a problem with the Battery Pack, please refer to the
Troubleshooting Guide in the UPS owner's Manual to correct the problem
or collect enough information so the Minuteman Technical Support
department can assist you.

4
RECEIVING INSPECTION
Upon receipt of the Battery Pack, check the outer packaging for any
external damage that may have been caused by the carrier. After
removing your Minuteman XRT Battery Pack from its carton, inspect the
unit again for any damage that may have occurred in shipping. Notify the
carrier and place of purchase immediately if any damage is found.
Warranty claims for damage caused by the carrier will not be honored.
PLEASE SAVE THE PACKING MATERIALS!
The packing materials in which the Battery Pack was shipped are
carefully designed to minimize any shipping damage. In the unlikely
event that the Battery Pack needs to be returned to Minuteman, please
use the original packing material. Since Minuteman is not responsible for
shipping damage incurred when the system is returned, the original
packing material is inexpensive insurance.
IMPORTANT SAFETY INSTRUCTIONS: SAVE THESE
INSTRUCTIONS - THIS MANUAL CONTAINS IMPORTANT
SAFETY INSTRUCTIONS!
Read this manual carefully before operating the UPS. All instructions and
warnings should be followed during installation, operation and
maintenance of the UPS.
CAUTION: A BATTERY CAN PRESENT A RISK OF
ELECTRICAL SHOCK OR BURN FROM HIGH
SHORT-CIRCUIT CURRENT. OBSERVE PROPER
PRECAUTIONS.
CAUTION: PROPER DISPOSAL OF BATTERIES IS
REQUIRED. REFER TO YOUR LOCAL CODES FOR
DISPOSAL REQUIREMENTS.

5
INSTRUCTIONS IMPORTANTES CONCERNANT LA SÉCURITÉ:
CONSERVER CES INSTRUCTIONS. CETTE NOTICE CONTIENT DES
INSTRUCTIONS IMPORTANTES CONCERNANT LA SÉCURITÉ.
ATTENTION: UNE BATTERIE PEUT PRÉSENTER
US RISQUE DE CHOC ÉLECTRIQUE, OU DE
BRULURE PAR TRANSFERT D'ENERGIE. SUIVRE
LES PRÉCAUTIONS QUI S'IMPOSENT.
CAUTION: AVOID INSTALLING THE BATTERY
PACKS IN LOCATIONS WHERE THERE IS WATER
OR EXCESSIVE HUMIDITY.
CAUTION: DO NOT ALLOW WATER OR ANY
FOREIGN OBJECTS TO GET INSIDE THE BATTERY
PACK. DO NOT PUT OBJECTS CONTAINING
LIQUIDS ON OR NEAR THE UNIT.
ATTENTION: L'EMINATION DES BATTERIES EST
RÉGLEMENTÉE. CONSULTER LES CODES
LOCAUX Á CET EFFET.
ATTENTION: NE PAS LAISSER DE L'EAU OU TOUT
OBJET PÉNÉTRER DANS LA SOURCE BATTERIE.
NE PAS PLACER DE RÉCIPIENTS CONTENANT UN
LIQUIDE SUR CET APPAREIL, NI Á PROXIMITÉ DE
CELUI-CI.
ATTENTION: NE PAS INSTALLER LA SOURCE
BATTERIE DANS UN ENDROIT OÚ IL Y A DE L'EAU
OU UNE HUMIDITÉ EXCESSIVE.

6
CAUTIONS:
It is recommended that you turn the UPS off and disconnect it from the
AC wall outlet prior to connecting or disconnecting the battery terminals.
If battery packs MUST be changed while the UPS is supplying power to
protected equipment, they can ONLY be changed while the AC line is
supplying power. DO NOT attempt to replace batteries or battery packs
while the UPS is in battery backup mode. Be extremely careful while
plugging or unplugging additional battery packs. Insure that the cable
connectors have the proper polarity aligned before plugging them
together. Improper alignment may result in a short circuit that can
destroy the battery packs and the UPS, as well as cause a fire and injury
hazard.
If a unit must be opened to replace the batteries, the following
precautions must be followed.
1. Disconnect all receptacles, line cords and battery connectors
BEFORE removing the case screws.
2. Remove watches, rings, and other metallic jewelry before servicing
the batteries.
3. Use tools with insulated handles.
4. Wear protective gloves and eyewear.
5. Do not lay tools or other objects on top of the batteries.
6. It is recommended that you make yourself a sketch of the batteries
and their connections BEFORE you attempt to remove the old
batteries. Insure all connections to the new batteries are EXACTLY
the same as they were on the old batteries.
7. Verify that all battery brackets and mechanical fittings are replaced
exactly as they were removed.

7
INSTALLATION PLACEMENT:
Select the location of the battery pack(s) with care and use the following
precautions;
1. Avoid locations near heating devices.
2. Avoid locations near water or excessive humidity.
3. Do not expose the Battery Pack to direct sunlight.
4. Route power cords where they cannot be walked on or damaged.
The battery packs and UPS unit must be placed on a level, smooth
surface and cannot be stacked more than 4 units high. All battery packs
that exceed 80 Lbs. must NOT be stacked more than 2 units high. The
UPS control unit must be installed on the side of the battery packs with
proper spacing between battery pack(s) and UPS, or on top of the battery
pack(s). DO NOT attempt to install battery packs on top of the control
unit.
BATTERY PACK CASTER REMOVAL:
Some Battery Pack cases are supplied with casters and provided with
replacement rubber feet. If mobility is not required, or if the Battery
Packs are to be stacked, the casters on the upper Battery Packs must be
removed and replaced by the rubber feet. Follow the instructions below
to install the rubber feet.
1. Move the Battery Pack into the area of its final location.
2. Remove the Battery Pack from the wooden skid.
3. Using appropriate support, raise the Battery Pack high enough to
gain access to the bolts securing the casters.
WARNING! Weight of the Battery Packs vary by model and are
extremely heavy. Use enough people, strong enough supports and
equipment to safely manipulate the Battery Packs.
4. Remove the four bolts securing the casters with the appropriate size
open-end wrench.
5. After removing each caster, screw the rubber feet into the holes
provided.

8
A suggested layout for stacking multiple battery packs should be
determined by the technician performing your installation. Each
installation is unique to the job site and should be reviewed and planned
PRIOR to moving this heavy equipment. Measuring the equipment and
the installation site may be required. Always make sure your floor
strength is sufficient to handle extreme weight when installing this heavy
equipment.
NOTE: Some MINUTEMAN XRT Battery Packs are designed for quick
connection (Plug and Play), while some are designed for hand wiring by a
qualified technician or electrician. Use appropriate cautions for each
model.
INSTALLATION PROCEDURES:
NOTE: MINUTEMAN XRT BATTERY PACKS ARE
AVAILABLE IN MULTIPLE CONFIGURATIONS. MAKE
SURE YOU FOLLOW THE PROCEDURES FOR THE
CONFIGURATION STYLE WHICH YOU ARE INSTALLING.
STYLE 1: PLUG & PLAY CONFIGURATION
STYLE 2: HARDWIRE CONFIGURATION
STYLE 3: HARDWIRE AND PLUG & PLAY COMBINATION
CONFIGURATION
STYLE 1: PLUG & PLAY CONFIGURATION INSTALLATION
1. Make sure the installation placement and caster removal procedures
mentioned above have been carefully followed.
2. Make sure the UPS Power switch is in the OFF position. If this
model of battery pack contains a circuit breaker, be sure that the
Battery Pack circuit breaker if in the OFF position.
3. Remove the self-stick protective strip from the rear of the UPS (not
required on all units) and from the battery pack cable.

9
4. Loosen but do not remove the retainer screws on the rear panel of
the UPS, then drop the retainer bracket down. This retaining bracket
is not present on all models.
5. Plug the cable connector into the XRT UPS remote battery pack
connector, insuring the connectors mate Red to Red and Black to
Black.
6. Push the retaining bracket "up" to secure the battery connector in
place and retighten the screws (not required on all models). Note: if
the retaining bracket will not slide up, the connector is not securely

10
installed all of the way into the receptacle. Upon successful
connection, verify that the bracket will not allow removal of the
connector.
For multiple battery pack installation, each battery pack is "daisy chained"
in a similar fashion, with the cable from the last battery pack connected to
the previous pack. Remove the protective strips only from the battery
connectors that you use.
NOTE: When the protective strip is removed from the XRT UPS or
the XRT Battery Pack cable and daisy-chain battery connector,
battery system voltage is present at these connector contacts
(48vdc, depending on model). Be sure the connector contacts are
covered with the protective strip when not mated with another
connector.
7. The unit is now ready for normal startup procedures as described in
the UPS owner's manual. Make sure all switches and breakers on all
units installed are placed in the ON position. Failure to have all of the
switches in the ON position may render the UPS inoperable or
reduce the runtime when multiple battery packs are installed.
STYLE 2: HARDWIRE CONFIGURATION INSTALLATION
1. Make sure the installation placement and caster removal procedures
mentioned above have been carefully followed.
2. Be sure the UPS Power switch is in the OFF position. If this model of
battery pack contains a circuit breaker, make sure the battery pack
circuit breaker is in the OFF position.
3. For installation of the battery pack connection wires, locate the
terminal block on the back of the UPS. To properly identify the
terminal block, refer to the Installation section in the UPS owner's
manual.
Autres manuels pour XRT Series
1
Table des matières
Autres manuels Minuteman Bloc de piles

Minuteman
Minuteman BP24XL Manuel utilisateur

Minuteman
Minuteman BP192RTXL Manuel utilisateur

Minuteman
Minuteman BP24RTEXL Manuel utilisateur

Minuteman
Minuteman BPRTXL Series Manuel utilisateur

Minuteman
Minuteman Endeavor Manuel utilisateur

Minuteman
Minuteman Rack/Tower Extended Runtime Battery Packs Manuel utilisateur
Manuels Bloc de piles populaires d'autres marques

IOGear
IOGear GBP24V Series Manuel utilisateur

Inventus Power
Inventus Power PROTRXion S-12V100-TRX-HD Manuel utilisateur

Clas Ohlson
Clas Ohlson PW-290A Manuel utilisateur

EINHELL
EINHELL MULTI-Ah Power X-Change Plus Manuel utilisateur

Samsung
Samsung EB-U3300 Manuel utilisateur

ECTIVE
ECTIVE LC Series Manuel utilisateur