www.milleredge.com info@milleredge.com 800-220-3343 2/4
ME123 SENSING EDGE
WIRELESS METHOD REQUIRED
Miller Edge wireless edge transmitter/receiver system
INSTALLATION
1. Consult the Miller Edge transmitter/receiver installation
instructions for wiring of the sensing edge.
2. For proper connection to operator inputs, please consult
the operator manual.
COIL CORD METHOD
Note: For specific operator input connection diagrams
and instructions, please consult your operator manual.
REQUIRED
Junction boxes (2) Mounting screws
Wire end caps 18-22 gauge wire
INSTALLATION
1. Mount the first junction box on the end stile or bottom bar
of the door.
2. Run the sensing edge lead wire into the junction box.
3. Mount the second junction box on an adjoining wall,
midway between the floor and the operator.
4. With the door in the closed position, secure the coil cord
to the first junction box.
5. Then run it, fully stretched, to the second wall mounted
junction box so the stretched length is equal to one-half of
the door opening.
6. Secure the coil cord into the wall junction box and trim the
coil cord. This assures the excess coil cord will not get
caught or hang in the opening of the door.
7. Secure 18-22 gauge wire into the second wall-mounted
junction box and hard wire to the operator sensing edge
terminals.
RETRACTING REEL METHOD
Note: For specific operator input connection diagrams
and instructions, please consult your operator manual.
REQUIRED
Junction box (1) Mounting screws
Wire end caps 18-22 gauge wire
INSTALLATION
NOT SUITABLE FOR MONITORED SENSING EDGES
1. Mount the junction box on the end stile or bottom bar of
the door.
2. Run the sensing edge lead wire into the junction box.
3. Mount the retracting reel on an adjoining wall, near the
operator.
4. With the door in the closed position, secure the retracting
reel cable to the junction box. The cable should freely
extend, without rubbing, in and out of the retracting reel for
the duration of the open/close cycle.
5. Using the 18-22 gauge wire, hardwire the retracting reel to
the sensing edge terminals of the operator.
3. SENSING EDGE INSTALLATION