Microcare 310V Manuel utilisateur

PV
BOOSTER
310/350/550V
User Manual
Manual Version: PVB-2017-2

Table of Contents
1. IMPORTANT INFORMATION AND SAFETY INSTRUCTIONS ..........................................1
2. INTRODUCTION .................................................................................................................2
2.1 General Description ........................................................................................................2
2.2 Key Features...................................................................................................................2
3. PV BOOSTER OVERVIEW .................................................................................................3
3.1 PV Booster Top View......................................................................................................3
3.2 PV Booster Side View.....................................................................................................3
4. PV Booster Sizing Criteria ...................................................................................................4
5. PV Booster Installation.........................................................................................................4
6. PV Booster Wiring –1 x PV Panel & 1 X PV Booster..........................................................5
7. PV Booster Wiring –2 x PV Panels & 2 X PV Boosters ......................................................6
8. PV Booster Wiring –3 x PV Panels & 3 X PV Boosters ......................................................7
9. PV BOOSTER SPECIFICATIONS.......................................................................................8
10. DESTRIER ELECTRONICS LIMITED CARRY- IN WARRANTY ........................................9
11. REGISTRATION OF MY MICROCARE PRODUCT..........................................................10

IMPORTANT INFORMATION AND SAFETY INSTRUCTIONS
1
1. IMPORTANT INFORMATION AND SAFETY INSTRUCTIONS
Installers should be qualified electricians or technicians
The installation information in the manual is for information purposes only.
Read the instructions carefully before installing and operating the PV Booster.
Retain the load within the rating to prevent faults.
Sketches are intended for illustrative purposes only and are not intended to provide an
electrical design.
High voltages are present –With this device even a single PV panel can produce a lethal 800
Volt DC.
This unit is not a consumer product and should only be handled by qualified electricians.
Always ground the device to avoid electric shock. A grounding wire connection is provided.
The inherent current limiting associated with a solar panel is part of the Solar Voltage Booster
design.
Running the unit from a battery or bench supply will cause it to fail, even when lightly loaded.
Never series the output of individual PV Boosters, as this will increase the output voltage
above the isolation specification of the unit and may cause electric shock
WARNING
HIGH VOLTAGES PRESENT
Voltages capable of causing severe injury or death by electrical shock are present in this
unit.
WARNING
Maximum Panel Input Voltage: 10V to 50V
Panel Power: Max 360W

INTRODUCTION
2
2. INTRODUCTION
General Description2.1
The Solar Voltage Booster steps up the voltage level of a photovoltaic (PV) panel to the level
required for the Microcare pump controller. This allows any number of voltage boosted solar panels
to be paralleled, removing the concept of „array voltage‟ when designing a solar pump system.
Key Features2.2
Solar Voltage Boosters are installed on a per-panel basis.
Each panel in the array requires an accompanying Booster. This limits the usefulness of the
Solar Voltage Booster to 375W, 550W, 750W and possibly 1.1kW installations. After that the
costs associated with the addition of Boosters are not currently economical.
The Solar Voltage Booster is specifically designed for standard 300W (250W to 350W) with a
Maximum Power voltage (VMP) of 35V to 40V.
Only PV Panels with an open circuit voltage (VOC) lower than 50V are supported.
At higher voltage levels the safety circuits will protect the Booster by short-circuiting the panel
input.
The Solar Voltage Booster is designed for mounting behind an accompanying PV panel.
Long feed-wires are not supported (longer than 4 meters) and may cause voltage spikes to
activate the protection circuits.
Solar Voltage Booster outputs should be paralleled.
To this end each Booster is fitted with a high voltage input.
The high voltage output of one Booster feeds into the high voltage input of the next Booster in
the string.
Please Note : Max Panel Input Voltage Voc : 10V to 50V
Panel Power: Max 360W

PV BOOSTER OVERVIEW
3
3. PV BOOSTER OVERVIEW
PV Booster Top View3.1 Figure 3-1
PV Booster Side View3.2
No
Description
1
Earth Connection
2
Solar Panel Negative Input -
3
Solar Panel Positive Input +
4
Panel LED
5
High Voltage LED
6
High Voltage Input Negative -
7
High Voltage Input Postitive +
8
High Voltage Output Negative -
9
High Voltage Output Positive +
1 2 3 4 5 6 7 8 9

PV Booster Sizing Criteria
4
4. PV Booster Sizing Criteria
Our PV Boosters are mostly used in conjunction with PV Arrays for our Solar Pump Controllers when
used to drive smaller submersible pumps. “0,375 – 0,75KW”.
350V Boosters to be used with 220V pump applications
550V Boosters to be used with 380V pump applications
Voc PV Panel Input Voltage : >20V and <50V
Vmp PV Panel Input Voltage : >12V and <40V
Panel Power : Max 360W panel per PV booster
Panel Voltage Input
310V Model Booster
Approximate Output
Voltage DC
350V Model Booster
Approximate Output
Voltage
550V Model Booster
Approximate Output
Voltage
Panel Vmp - 37V
310V
350V
550V
Panel Vmp –38V
315V
357V
566V
Panel VMP –39V
324V
367V
581V
Panel VMP –40V
332V
376V
596V
Ratio Vin:Vout
1:8,3
1:9,4
1:14,9
5. PV Booster Installation
Mount the PV Booster to the PV panel by means of screws.
Ensure that the load is disconnected from the solar panels before connecting the booster/s wiring to
the panel/s.

PV Booster Wiring –1 x PV Panel & 1 X PV Booster
5
6. PV Booster Wiring –1 x PV Panel & 1 X PV Booster
Panel Input 37V –Booster Output 350V

PV Booster Wiring –2 x PV Panels & 2 X PV Boosters
6
7. PV Booster Wiring –2 x PV Panels & 2 X PV Boosters
Panel Input 37V –Booster Output 350V

PV Booster Wiring –3 x PV Panels & 3 X PV Boosters
7
8. PV Booster Wiring –3 x PV Panels & 3 X PV Boosters
Panel Input 37V –Booster Output 350V

PV BOOSTER SPECIFICATIONS
8
9. PV BOOSTER SPECIFICATIONS
Model
310
350
550
PV VOC Range
20V to 50V
20V to 50V
20V to 50V
PV VMP Range
12V to 40V
12V to 40V
12V to 40V
Output Voltage at
37V input
350V
350V
550V
Voltage multiplication
factor
8.3
9.4
14.9
Rated Output Power
360W
360W
360W
Efficiency
95% (over wide range)
95% (over wide range)
95% (over wide range)
Ambient Temp Range
-40°C to 75°C
-40°C to 75°C
-40°C to 75°C
Protection
4.5kA surge protection
4.5kA surge protection
4.5kA surge protection
Dimensions (HxWxD)
70x100x36mm
70x100x36mm
70x100x36mm
Warranty
Ce manuel convient aux modèles suivants
2
Table des matières
Autres manuels Microcare Onduleur

Microcare
Microcare 10 Amp Manuel utilisateur

Microcare
Microcare Kaco Manuel utilisateur

Microcare
Microcare 5kW48V Manuel utilisateur

Microcare
Microcare 12/1000 Manuel utilisateur

Microcare
Microcare 600W-24V Manuel utilisateur

Microcare
Microcare Pure Sine Wave Bi-Directional Inverter 10Kw Manuel utilisateur