EasyTouch RV 356
9
©2023 Micro-Air LLC Revision 2.1
Initial Setup Instructions
Configure your Available Outputs
EasyTouch RV 356 is meant to replace a few different OEM
thermostats and so must be configured for your system prior to using it. Tap
the Settings button on the main screen, then navigate to the Setup button and
tap it. The first page is to configure the hardware in your specific system. Tap
the heat pump button to enable or disable it based on what is installed in
your system. A red circle with a line through it over the button indicates
disabled. Cool and furnace are always enabled.
Configure Auto-Gen Start (AGS)
Some systems have hardware to allow for a generator to start prior
to a cycle occurring that needs it. These systems are commonly labeled
“TrueAir” and are often found in Winnebago products, but not all have Auto-
Gen Start (AGS). The hardware for (AGS) is not part of the thermostat but it
must be configured to know if it is available. Use section Check for Additional
Hardware –Software Setup for Later to know what you have.
Tap the AGS Available/Unavailable button under the “Auto Gen-
Start”heading to set it based on what you have. If set as “Available”then
the Generator button will appear and you can turn the functionality on or off.
Setting this to “Unavailable” is the default and should be used for all non-
AGS systems.
Warning: You MUST configure AGS availability appropriately or your thermostat may not function as
designed. You CANNOT enable this function unless you know you have the appropriate hardware. See
section Check for Additional Hardware –if you are not sure. This can also be found in your original
thermostat’s manual. Micro-Air cannot assist with acquiring AGS hardware.
Auto Gas Changeover Type
You can choose the auto gas changeover type by tapping the Type
button on the second page. Each “version”has slightly different logic to use
all of your available heat modes in stages based on how far the inside
temperature is from the set-point. Each version corresponds to a version of
the OEM thermostats behavior, as well as a “Disabled” option. Use the “GC
Ver” column of Table 2 and Table 3 to match the version to your original
thermostat. “Version A” has the broadest coverage if not sure.
You can also adjust parameters for the Auto Gas Changeover to operate its logic. The temperature at which
stages escalate can be set, as well as the maximum run time for a lower stage to escalate. See section Auto
Gas Changeover in section Operating the Thermostat for more details on this operation and the configurable
parameters.
Connecting Remotely
EasyTouch RV can be operated entirely by the touchscreen, however you can
also communicate, monitor, and modify operation of it wirelessly using the EasyTouch
RV application. Some extra features will require a wireless connection and is
described in their sections. See Appendix A: Working Wirelessly for details.